ABAP Select data from SAP table V51P_GEW_VOL into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP V51P_GEW_VOL table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to V51P_GEW_VOL. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the V51P_GEW_VOL table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_V51P_GEW_VOL TYPE STANDARD TABLE OF V51P_GEW_VOL,
      WA_V51P_GEW_VOL TYPE V51P_GEW_VOL,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <V51P_GEW_VOL> TYPE V51P_GEW_VOL.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_V51P_GEW_VOL.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM V51P_GEW_VOL
  INTO TABLE IT_V51P_GEW_VOL.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM V51P_GEW_VOL
*  INTO TABLE @DATA(IT_V51P_GEW_VOL2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_V51P_GEW_VOL INDEX 1 INTO DATA(WA_V51P_GEW_VOL2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_V51P_GEW_VOL ASSIGNING <V51P_GEW_VOL>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<V51P_GEW_VOL>-TARAG = 1.
<V51P_GEW_VOL>-GEWEI = 1.
<V51P_GEW_VOL>-BRGEW = 1.
<V51P_GEW_VOL>-NTGEW = 1.
<V51P_GEW_VOL>-MAGEW = 1.
ENDLOOP.

LOOP AT IT_V51P_GEW_VOL INTO WA_V51P_GEW_VOL.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_V51P_GEW_VOL-GEWEI_MAX, sy-vline,
WA_V51P_GEW_VOL-GEWTO, sy-vline,
WA_V51P_GEW_VOL-TAVOL, sy-vline,
WA_V51P_GEW_VOL-VOLEH, sy-vline,
WA_V51P_GEW_VOL-BTVOL, sy-vline,
WA_V51P_GEW_VOL-NTVOL, sy-vline.
ENDLOOP. *Add any further fields from structure WA_V51P_GEW_VOL you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_V51P_GEW_VOL TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_V51P_GEW_VOL INTO WA_V51P_GEW_VOL. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit CUNIT, internal->external for field GEWEI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_V51P_GEW_VOL-GEWEI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V51P_GEW_VOL-GEWEI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field GEWEI_MAX CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_V51P_GEW_VOL-GEWEI_MAX IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V51P_GEW_VOL-GEWEI_MAX.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field VOLEH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_V51P_GEW_VOL-VOLEH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V51P_GEW_VOL-VOLEH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field VOLEH_MAX CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_V51P_GEW_VOL-VOLEH_MAX IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_V51P_GEW_VOL-VOLEH_MAX.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_V51P_GEW_VOL_STR,
TARAG TYPE STRING,
GEWEI TYPE STRING,
BRGEW TYPE STRING,
NTGEW TYPE STRING,
MAGEW TYPE STRING,
GEWEI_MAX TYPE STRING,
GEWTO TYPE STRING,
TAVOL TYPE STRING,
VOLEH TYPE STRING,
BTVOL TYPE STRING,
NTVOL TYPE STRING,
MAVOL TYPE STRING,
VOLEH_MAX TYPE STRING,
VOLTO TYPE STRING,
KZGVH TYPE STRING,
TARAVAR TYPE STRING,END OF T_EKKO_STR. DATA: WA_V51P_GEW_VOL_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_V51P_GEW_VOL_STR-TARAG sy-vline
WA_V51P_GEW_VOL_STR-GEWEI sy-vline
WA_V51P_GEW_VOL_STR-BRGEW sy-vline
WA_V51P_GEW_VOL_STR-NTGEW sy-vline
WA_V51P_GEW_VOL_STR-MAGEW sy-vline
WA_V51P_GEW_VOL_STR-GEWEI_MAX sy-vline
WA_V51P_GEW_VOL_STR-GEWTO sy-vline
WA_V51P_GEW_VOL_STR-TAVOL sy-vline
WA_V51P_GEW_VOL_STR-VOLEH sy-vline
WA_V51P_GEW_VOL_STR-BTVOL sy-vline
WA_V51P_GEW_VOL_STR-NTVOL sy-vline
WA_V51P_GEW_VOL_STR-MAVOL sy-vline
WA_V51P_GEW_VOL_STR-VOLEH_MAX sy-vline
WA_V51P_GEW_VOL_STR-VOLTO sy-vline
WA_V51P_GEW_VOL_STR-KZGVH sy-vline
WA_V51P_GEW_VOL_STR-TARAVAR sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.