ABAP Select data from SAP table UTILS_S_BIT_QUANTITY_PRINT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP UTILS_S_BIT_QUANTITY_PRINT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to UTILS_S_BIT_QUANTITY_PRINT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the UTILS_S_BIT_QUANTITY_PRINT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_UTILS_S_BIT_QUANTITY_PRINT TYPE STANDARD TABLE OF UTILS_S_BIT_QUANTITY_PRINT,
      WA_UTILS_S_BIT_QUANTITY_PRINT TYPE UTILS_S_BIT_QUANTITY_PRINT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <UTILS_S_BIT_QUANTITY_PRINT> TYPE UTILS_S_BIT_QUANTITY_PRINT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_UTILS_S_BIT_QUANTITY_PRINT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM UTILS_S_BIT_QUANTITY_PRINT
  INTO TABLE IT_UTILS_S_BIT_QUANTITY_PRINT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM UTILS_S_BIT_QUANTITY_PRINT
*  INTO TABLE @DATA(IT_UTILS_S_BIT_QUANTITY_PRINT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_UTILS_S_BIT_QUANTITY_PRINT INDEX 1 INTO DATA(WA_UTILS_S_BIT_QUANTITY_PRINT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_UTILS_S_BIT_QUANTITY_PRINT ASSIGNING <UTILS_S_BIT_QUANTITY_PRINT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<UTILS_S_BIT_QUANTITY_PRINT>-SRCTATYPE = 1.
<UTILS_S_BIT_QUANTITY_PRINT>-SRCTAID = 1.
<UTILS_S_BIT_QUANTITY_PRINT>-DEVICE_NUMBER = 1.
<UTILS_S_BIT_QUANTITY_PRINT>-REGISTER_NUMBER = 1.
<UTILS_S_BIT_QUANTITY_PRINT>-DATE_FROM = 1.
ENDLOOP.

LOOP AT IT_UTILS_S_BIT_QUANTITY_PRINT INTO WA_UTILS_S_BIT_QUANTITY_PRINT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_UTILS_S_BIT_QUANTITY_PRINT-DATE_TO, sy-vline,
WA_UTILS_S_BIT_QUANTITY_PRINT-PREVIOUS_METER_READING, sy-vline,
WA_UTILS_S_BIT_QUANTITY_PRINT-METER_READING, sy-vline,
WA_UTILS_S_BIT_QUANTITY_PRINT-METER_READING_CATEGORY, sy-vline,
WA_UTILS_S_BIT_QUANTITY_PRINT-METER_READING_CATEGORY_TXT, sy-vline,
WA_UTILS_S_BIT_QUANTITY_PRINT-METER_READING_DIFF, sy-vline.
ENDLOOP. *Add any further fields from structure WA_UTILS_S_BIT_QUANTITY_PRINT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_UTILS_S_BIT_QUANTITY_PRINT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_UTILS_S_BIT_QUANTITY_PRINT INTO WA_UTILS_S_BIT_QUANTITY_PRINT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field SRCTAID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_UTILS_S_BIT_QUANTITY_PRINT-SRCTAID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_UTILS_S_BIT_QUANTITY_PRINT-SRCTAID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GERNR, internal->external for field DEVICE_NUMBER CALL FUNCTION 'CONVERSION_EXIT_GERNR_OUTPUT' EXPORTING input = WA_UTILS_S_BIT_QUANTITY_PRINT-DEVICE_NUMBER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_UTILS_S_BIT_QUANTITY_PRINT-DEVICE_NUMBER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field METER_READING_MSMT_UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_UTILS_S_BIT_QUANTITY_PRINT-METER_READING_MSMT_UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_UTILS_S_BIT_QUANTITY_PRINT-METER_READING_MSMT_UNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field QUANTITY_MSMT_UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_UTILS_S_BIT_QUANTITY_PRINT-QUANTITY_MSMT_UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_UTILS_S_BIT_QUANTITY_PRINT-QUANTITY_MSMT_UNIT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_UTILS_S_BIT_QUANTITY_PRINT_STR,
SRCTATYPE TYPE STRING,
SRCTAID TYPE STRING,
DEVICE_NUMBER TYPE STRING,
REGISTER_NUMBER TYPE STRING,
DATE_FROM TYPE STRING,
DATE_TO TYPE STRING,
PREVIOUS_METER_READING TYPE STRING,
METER_READING TYPE STRING,
METER_READING_CATEGORY TYPE STRING,
METER_READING_CATEGORY_TXT TYPE STRING,
METER_READING_DIFF TYPE STRING,
METER_READING_MSMT_UNIT TYPE STRING,
QUANTITY TYPE STRING,
QUANTITY_MSMT_UNIT TYPE STRING,
QUANTITY_MSMT_UNIT_TECH TYPE STRING,
MR_MSMT_UNIT_TECH TYPE STRING,
CONVERSION TYPE STRING,
CONVERSION_TAB TYPE STRING,END OF T_EKKO_STR. DATA: WA_UTILS_S_BIT_QUANTITY_PRINT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_UTILS_S_BIT_QUANTITY_PRINT_STR-SRCTATYPE sy-vline
WA_UTILS_S_BIT_QUANTITY_PRINT_STR-SRCTAID sy-vline
WA_UTILS_S_BIT_QUANTITY_PRINT_STR-DEVICE_NUMBER sy-vline
WA_UTILS_S_BIT_QUANTITY_PRINT_STR-REGISTER_NUMBER sy-vline
WA_UTILS_S_BIT_QUANTITY_PRINT_STR-DATE_FROM sy-vline
WA_UTILS_S_BIT_QUANTITY_PRINT_STR-DATE_TO sy-vline
WA_UTILS_S_BIT_QUANTITY_PRINT_STR-PREVIOUS_METER_READING sy-vline
WA_UTILS_S_BIT_QUANTITY_PRINT_STR-METER_READING sy-vline
WA_UTILS_S_BIT_QUANTITY_PRINT_STR-METER_READING_CATEGORY sy-vline
WA_UTILS_S_BIT_QUANTITY_PRINT_STR-METER_READING_CATEGORY_TXT sy-vline
WA_UTILS_S_BIT_QUANTITY_PRINT_STR-METER_READING_DIFF sy-vline
WA_UTILS_S_BIT_QUANTITY_PRINT_STR-METER_READING_MSMT_UNIT sy-vline
WA_UTILS_S_BIT_QUANTITY_PRINT_STR-QUANTITY sy-vline
WA_UTILS_S_BIT_QUANTITY_PRINT_STR-QUANTITY_MSMT_UNIT sy-vline
WA_UTILS_S_BIT_QUANTITY_PRINT_STR-QUANTITY_MSMT_UNIT_TECH sy-vline
WA_UTILS_S_BIT_QUANTITY_PRINT_STR-MR_MSMT_UNIT_TECH sy-vline
WA_UTILS_S_BIT_QUANTITY_PRINT_STR-CONVERSION sy-vline
WA_UTILS_S_BIT_QUANTITY_PRINT_STR-CONVERSION_TAB sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.