ABAP Select data from SAP table UPS_S_OD_WELL_TEST into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP UPS_S_OD_WELL_TEST table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to UPS_S_OD_WELL_TEST. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the UPS_S_OD_WELL_TEST table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_UPS_S_OD_WELL_TEST TYPE STANDARD TABLE OF UPS_S_OD_WELL_TEST,
      WA_UPS_S_OD_WELL_TEST TYPE UPS_S_OD_WELL_TEST,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <UPS_S_OD_WELL_TEST> TYPE UPS_S_OD_WELL_TEST.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_UPS_S_OD_WELL_TEST.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM UPS_S_OD_WELL_TEST
  INTO TABLE IT_UPS_S_OD_WELL_TEST.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM UPS_S_OD_WELL_TEST
*  INTO TABLE @DATA(IT_UPS_S_OD_WELL_TEST2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_UPS_S_OD_WELL_TEST INDEX 1 INTO DATA(WA_UPS_S_OD_WELL_TEST2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_UPS_S_OD_WELL_TEST ASSIGNING <UPS_S_OD_WELL_TEST>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<UPS_S_OD_WELL_TEST>-PRODUCTIONNETWORK = 1.
<UPS_S_OD_WELL_TEST>-NETWORKOBJECT = 1.
<UPS_S_OD_WELL_TEST>-NETWORKOBJECTTYPE = 1.
<UPS_S_OD_WELL_TEST>-INSPLOT = 1.
<UPS_S_OD_WELL_TEST>-EFFECTIVEFROM = 1.
ENDLOOP.

LOOP AT IT_UPS_S_OD_WELL_TEST INTO WA_UPS_S_OD_WELL_TEST.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_UPS_S_OD_WELL_TEST-EFFECTIVETO, sy-vline,
WA_UPS_S_OD_WELL_TEST-WELLTESTSTARTDATE, sy-vline,
WA_UPS_S_OD_WELL_TEST-WELLTESTENDDATE, sy-vline,
WA_UPS_S_OD_WELL_TEST-OPERATION, sy-vline,
WA_UPS_S_OD_WELL_TEST-CHANGED_BY, sy-vline,
WA_UPS_S_OD_WELL_TEST-CHANGED_TST, sy-vline.
ENDLOOP. *Add any further fields from structure WA_UPS_S_OD_WELL_TEST you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_UPS_S_OD_WELL_TEST TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_UPS_S_OD_WELL_TEST INTO WA_UPS_S_OD_WELL_TEST. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit GHONO, internal->external for field PRODUCTIONNETWORK CALL FUNCTION 'CONVERSION_EXIT_GHONO_OUTPUT' EXPORTING input = WA_UPS_S_OD_WELL_TEST-PRODUCTIONNETWORK IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_UPS_S_OD_WELL_TEST-PRODUCTIONNETWORK.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GHONO, internal->external for field NETWORKOBJECT CALL FUNCTION 'CONVERSION_EXIT_GHONO_OUTPUT' EXPORTING input = WA_UPS_S_OD_WELL_TEST-NETWORKOBJECT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_UPS_S_OD_WELL_TEST-NETWORKOBJECT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field INSPLOT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_UPS_S_OD_WELL_TEST-INSPLOT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_UPS_S_OD_WELL_TEST-INSPLOT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TPLNR, internal->external for field PRODUCTIONNETWORK CALL FUNCTION 'CONVERSION_EXIT_TPLNR_OUTPUT' EXPORTING input = WA_UPS_S_OD_WELL_TEST-PRODUCTIONNETWORK IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_UPS_S_OD_WELL_TEST-PRODUCTIONNETWORK.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TPLNR, internal->external for field NETWORKOBJECT CALL FUNCTION 'CONVERSION_EXIT_TPLNR_OUTPUT' EXPORTING input = WA_UPS_S_OD_WELL_TEST-NETWORKOBJECT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_UPS_S_OD_WELL_TEST-NETWORKOBJECT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field INSPLOT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_UPS_S_OD_WELL_TEST-INSPLOT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_UPS_S_OD_WELL_TEST-INSPLOT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_UPS_S_OD_WELL_TEST_STR,
PRODUCTIONNETWORK TYPE STRING,
NETWORKOBJECT TYPE STRING,
NETWORKOBJECTTYPE TYPE STRING,
INSPLOT TYPE STRING,
EFFECTIVEFROM TYPE STRING,
EFFECTIVETO TYPE STRING,
WELLTESTSTARTDATE TYPE STRING,
WELLTESTENDDATE TYPE STRING,
OPERATION TYPE STRING,
CHANGED_BY TYPE STRING,
CHANGED_TST TYPE STRING,
AUTH_CREATE TYPE STRING,
AUTH_READ TYPE STRING,
AUTH_UPDATE TYPE STRING,
AUTH_DELETE TYPE STRING,
ALERT_ID TYPE STRING,
AUDITREASON TYPE STRING,
PROCESSTYPE TYPE STRING,
AUDIT_PPA_INDICATOR TYPE STRING,
PPA_REASON_DESC TYPE STRING,
PPA_LOCK TYPE STRING,
PPA_REQUESTER_FLAG TYPE STRING,
REQUESTER TYPE STRING,
MEAS_CAT_ID TYPE STRING,
MEAS_CAT_ID_DESC TYPE STRING,
WELLTEST_INTERVAL TYPE STRING,
FDCWELLTESTITEMSET TYPE STRING,
FDCWELLTESTPPA TYPE STRING,
PRODUCTIONNETWORK TYPE STRING,
NETWORKOBJECT TYPE STRING,
NETWORKOBJECTTYPE TYPE STRING,
INSPLOT TYPE STRING,
PROCESS_TYPE TYPE STRING,
ELIGIBILITY_INDI TYPE STRING,
PPA_REASON_DESC TYPE STRING,
AUDIT_REASON_CODE TYPE STRING,
MEAS_CAT_ID TYPE STRING,END OF T_EKKO_STR. DATA: WA_UPS_S_OD_WELL_TEST_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_UPS_S_OD_WELL_TEST_STR-PRODUCTIONNETWORK sy-vline
WA_UPS_S_OD_WELL_TEST_STR-NETWORKOBJECT sy-vline
WA_UPS_S_OD_WELL_TEST_STR-NETWORKOBJECTTYPE sy-vline
WA_UPS_S_OD_WELL_TEST_STR-INSPLOT sy-vline
WA_UPS_S_OD_WELL_TEST_STR-EFFECTIVEFROM sy-vline
WA_UPS_S_OD_WELL_TEST_STR-EFFECTIVETO sy-vline
WA_UPS_S_OD_WELL_TEST_STR-WELLTESTSTARTDATE sy-vline
WA_UPS_S_OD_WELL_TEST_STR-WELLTESTENDDATE sy-vline
WA_UPS_S_OD_WELL_TEST_STR-OPERATION sy-vline
WA_UPS_S_OD_WELL_TEST_STR-CHANGED_BY sy-vline
WA_UPS_S_OD_WELL_TEST_STR-CHANGED_TST sy-vline
WA_UPS_S_OD_WELL_TEST_STR-AUTH_CREATE sy-vline
WA_UPS_S_OD_WELL_TEST_STR-AUTH_READ sy-vline
WA_UPS_S_OD_WELL_TEST_STR-AUTH_UPDATE sy-vline
WA_UPS_S_OD_WELL_TEST_STR-AUTH_DELETE sy-vline
WA_UPS_S_OD_WELL_TEST_STR-ALERT_ID sy-vline
WA_UPS_S_OD_WELL_TEST_STR-AUDITREASON sy-vline
WA_UPS_S_OD_WELL_TEST_STR-PROCESSTYPE sy-vline
WA_UPS_S_OD_WELL_TEST_STR-AUDIT_PPA_INDICATOR sy-vline
WA_UPS_S_OD_WELL_TEST_STR-PPA_REASON_DESC sy-vline
WA_UPS_S_OD_WELL_TEST_STR-PPA_LOCK sy-vline
WA_UPS_S_OD_WELL_TEST_STR-PPA_REQUESTER_FLAG sy-vline
WA_UPS_S_OD_WELL_TEST_STR-REQUESTER sy-vline
WA_UPS_S_OD_WELL_TEST_STR-MEAS_CAT_ID sy-vline
WA_UPS_S_OD_WELL_TEST_STR-MEAS_CAT_ID_DESC sy-vline
WA_UPS_S_OD_WELL_TEST_STR-WELLTEST_INTERVAL sy-vline
WA_UPS_S_OD_WELL_TEST_STR-FDCWELLTESTITEMSET sy-vline
WA_UPS_S_OD_WELL_TEST_STR-FDCWELLTESTPPA sy-vline
WA_UPS_S_OD_WELL_TEST_STR-PRODUCTIONNETWORK sy-vline
WA_UPS_S_OD_WELL_TEST_STR-NETWORKOBJECT sy-vline
WA_UPS_S_OD_WELL_TEST_STR-NETWORKOBJECTTYPE sy-vline
WA_UPS_S_OD_WELL_TEST_STR-INSPLOT sy-vline
WA_UPS_S_OD_WELL_TEST_STR-PROCESS_TYPE sy-vline
WA_UPS_S_OD_WELL_TEST_STR-ELIGIBILITY_INDI sy-vline
WA_UPS_S_OD_WELL_TEST_STR-PPA_REASON_DESC sy-vline
WA_UPS_S_OD_WELL_TEST_STR-AUDIT_REASON_CODE sy-vline
WA_UPS_S_OD_WELL_TEST_STR-MEAS_CAT_ID sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.