ABAP Select data from SAP table UPS_S_OD_MEASUREMENT_RDG_UPD into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP UPS_S_OD_MEASUREMENT_RDG_UPD table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to UPS_S_OD_MEASUREMENT_RDG_UPD. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the UPS_S_OD_MEASUREMENT_RDG_UPD table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_UPS_S_OD_MEASUREMENT_RDG_UPD TYPE STANDARD TABLE OF UPS_S_OD_MEASUREMENT_RDG_UPD,
      WA_UPS_S_OD_MEASUREMENT_RDG_UPD TYPE UPS_S_OD_MEASUREMENT_RDG_UPD,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <UPS_S_OD_MEASUREMENT_RDG_UPD> TYPE UPS_S_OD_MEASUREMENT_RDG_UPD.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_UPS_S_OD_MEASUREMENT_RDG_UPD.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM UPS_S_OD_MEASUREMENT_RDG_UPD
  INTO TABLE IT_UPS_S_OD_MEASUREMENT_RDG_UPD.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM UPS_S_OD_MEASUREMENT_RDG_UPD
*  INTO TABLE @DATA(IT_UPS_S_OD_MEASUREMENT_RDG_UPD2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_UPS_S_OD_MEASUREMENT_RDG_UPD INDEX 1 INTO DATA(WA_UPS_S_OD_MEASUREMENT_RDG_UPD2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_UPS_S_OD_MEASUREMENT_RDG_UPD ASSIGNING <UPS_S_OD_MEASUREMENT_RDG_UPD>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<UPS_S_OD_MEASUREMENT_RDG_UPD>-PRODUCTIONNETWORK = 1.
<UPS_S_OD_MEASUREMENT_RDG_UPD>-FREQUENCY = 1.
<UPS_S_OD_MEASUREMENT_RDG_UPD>-NETWORKOBJECT = 1.
<UPS_S_OD_MEASUREMENT_RDG_UPD>-NETWORKOBJECT_TYPE = 1.
<UPS_S_OD_MEASUREMENT_RDG_UPD>-MEASMNT_TIMESTAMP = 1.
ENDLOOP.

LOOP AT IT_UPS_S_OD_MEASUREMENT_RDG_UPD INTO WA_UPS_S_OD_MEASUREMENT_RDG_UPD.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_UPS_S_OD_MEASUREMENT_RDG_UPD-QTY_TYPE, sy-vline,
WA_UPS_S_OD_MEASUREMENT_RDG_UPD-ALLOC_MAT, sy-vline,
WA_UPS_S_OD_MEASUREMENT_RDG_UPD-MEAS_CAT_ID, sy-vline,
WA_UPS_S_OD_MEASUREMENT_RDG_UPD-ALLOC_MAT_DESC, sy-vline,
WA_UPS_S_OD_MEASUREMENT_RDG_UPD-QTY_TYPE_DESC, sy-vline,
WA_UPS_S_OD_MEASUREMENT_RDG_UPD-MEAS_CAT_ID_DESC, sy-vline.
ENDLOOP. *Add any further fields from structure WA_UPS_S_OD_MEASUREMENT_RDG_UPD you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_UPS_S_OD_MEASUREMENT_RDG_UPD TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_UPS_S_OD_MEASUREMENT_RDG_UPD INTO WA_UPS_S_OD_MEASUREMENT_RDG_UPD. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit GHONO, internal->external for field PRODUCTIONNETWORK CALL FUNCTION 'CONVERSION_EXIT_GHONO_OUTPUT' EXPORTING input = WA_UPS_S_OD_MEASUREMENT_RDG_UPD-PRODUCTIONNETWORK IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_UPS_S_OD_MEASUREMENT_RDG_UPD-PRODUCTIONNETWORK.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GHONO, internal->external for field NETWORKOBJECT CALL FUNCTION 'CONVERSION_EXIT_GHONO_OUTPUT' EXPORTING input = WA_UPS_S_OD_MEASUREMENT_RDG_UPD-NETWORKOBJECT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_UPS_S_OD_MEASUREMENT_RDG_UPD-NETWORKOBJECT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field ALLOC_MAT CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_UPS_S_OD_MEASUREMENT_RDG_UPD-ALLOC_MAT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_UPS_S_OD_MEASUREMENT_RDG_UPD-ALLOC_MAT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field MEASMNT_POINT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_UPS_S_OD_MEASUREMENT_RDG_UPD-MEASMNT_POINT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_UPS_S_OD_MEASUREMENT_RDG_UPD-MEASMNT_POINT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field TRNSP_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_UPS_S_OD_MEASUREMENT_RDG_UPD-TRNSP_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_UPS_S_OD_MEASUREMENT_RDG_UPD-TRNSP_NO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GHONO, internal->external for field TO_PROD_NETWORK CALL FUNCTION 'CONVERSION_EXIT_GHONO_OUTPUT' EXPORTING input = WA_UPS_S_OD_MEASUREMENT_RDG_UPD-TO_PROD_NETWORK IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_UPS_S_OD_MEASUREMENT_RDG_UPD-TO_PROD_NETWORK.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GHONO, internal->external for field TO_NETWORK_OBJ CALL FUNCTION 'CONVERSION_EXIT_GHONO_OUTPUT' EXPORTING input = WA_UPS_S_OD_MEASUREMENT_RDG_UPD-TO_NETWORK_OBJ IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_UPS_S_OD_MEASUREMENT_RDG_UPD-TO_NETWORK_OBJ.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GHONO, internal->external for field ORIGINATING_MP CALL FUNCTION 'CONVERSION_EXIT_GHONO_OUTPUT' EXPORTING input = WA_UPS_S_OD_MEASUREMENT_RDG_UPD-ORIGINATING_MP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_UPS_S_OD_MEASUREMENT_RDG_UPD-ORIGINATING_MP.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_UPS_S_OD_MEASUREMENT_RDG_UPD_STR,
PRODUCTIONNETWORK TYPE STRING,
FREQUENCY TYPE STRING,
NETWORKOBJECT TYPE STRING,
NETWORKOBJECT_TYPE TYPE STRING,
MEASMNT_TIMESTAMP TYPE STRING,
QTY_TYPE TYPE STRING,
ALLOC_MAT TYPE STRING,
MEAS_CAT_ID TYPE STRING,
ALLOC_MAT_DESC TYPE STRING,
QTY_TYPE_DESC TYPE STRING,
MEAS_CAT_ID_DESC TYPE STRING,
MEDIUM TYPE STRING,
BUS_KEY TYPE STRING,
MEASMNT_POINT TYPE STRING,
MANUAL_FLAG TYPE STRING,
MRH_INDICATOR TYPE STRING,
CHANGED_TST TYPE STRING,
OPERATION TYPE STRING,
AUDIT_FLAG TYPE STRING,
AUDIT_REASON_CODE TYPE STRING,
PPA_DESC TYPE STRING,
STATUS_TEXT TYPE STRING,
ALERT_ID TYPE STRING,
AUTH_INS TYPE STRING,
AUTH_DIS TYPE STRING,
AUTH_CHG TYPE STRING,
AUTH_DEL TYPE STRING,
PPA_LOCK TYPE STRING,
PPA_REQUESTER_FLAG TYPE STRING,
REQUESTER TYPE STRING,
TRNSP_NO TYPE STRING,
TRNSP_REF_NO TYPE STRING,
TKT_NO TYPE STRING,
TRANSP_NAME TYPE STRING,
TO_PROD_NETWORK TYPE STRING,
TO_NETOBJ_TYPE TYPE STRING,
TO_NETOBJ_TY_DES TYPE STRING,
TO_NETWORK_OBJ TYPE STRING,
LD_OIL_WO_RECOV TYPE STRING,
ORIGINATING_MP TYPE STRING,
QTY_CATEGORY TYPE STRING,
FDCMEASUREMENTRAWSET TYPE STRING,END OF T_EKKO_STR. DATA: WA_UPS_S_OD_MEASUREMENT_RDG_UPD_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_UPS_S_OD_MEASUREMENT_RDG_UPD_STR-PRODUCTIONNETWORK sy-vline
WA_UPS_S_OD_MEASUREMENT_RDG_UPD_STR-FREQUENCY sy-vline
WA_UPS_S_OD_MEASUREMENT_RDG_UPD_STR-NETWORKOBJECT sy-vline
WA_UPS_S_OD_MEASUREMENT_RDG_UPD_STR-NETWORKOBJECT_TYPE sy-vline
WA_UPS_S_OD_MEASUREMENT_RDG_UPD_STR-MEASMNT_TIMESTAMP sy-vline
WA_UPS_S_OD_MEASUREMENT_RDG_UPD_STR-QTY_TYPE sy-vline
WA_UPS_S_OD_MEASUREMENT_RDG_UPD_STR-ALLOC_MAT sy-vline
WA_UPS_S_OD_MEASUREMENT_RDG_UPD_STR-MEAS_CAT_ID sy-vline
WA_UPS_S_OD_MEASUREMENT_RDG_UPD_STR-ALLOC_MAT_DESC sy-vline
WA_UPS_S_OD_MEASUREMENT_RDG_UPD_STR-QTY_TYPE_DESC sy-vline
WA_UPS_S_OD_MEASUREMENT_RDG_UPD_STR-MEAS_CAT_ID_DESC sy-vline
WA_UPS_S_OD_MEASUREMENT_RDG_UPD_STR-MEDIUM sy-vline
WA_UPS_S_OD_MEASUREMENT_RDG_UPD_STR-BUS_KEY sy-vline
WA_UPS_S_OD_MEASUREMENT_RDG_UPD_STR-MEASMNT_POINT sy-vline
WA_UPS_S_OD_MEASUREMENT_RDG_UPD_STR-MANUAL_FLAG sy-vline
WA_UPS_S_OD_MEASUREMENT_RDG_UPD_STR-MRH_INDICATOR sy-vline
WA_UPS_S_OD_MEASUREMENT_RDG_UPD_STR-CHANGED_TST sy-vline
WA_UPS_S_OD_MEASUREMENT_RDG_UPD_STR-OPERATION sy-vline
WA_UPS_S_OD_MEASUREMENT_RDG_UPD_STR-AUDIT_FLAG sy-vline
WA_UPS_S_OD_MEASUREMENT_RDG_UPD_STR-AUDIT_REASON_CODE sy-vline
WA_UPS_S_OD_MEASUREMENT_RDG_UPD_STR-PPA_DESC sy-vline
WA_UPS_S_OD_MEASUREMENT_RDG_UPD_STR-STATUS_TEXT sy-vline
WA_UPS_S_OD_MEASUREMENT_RDG_UPD_STR-ALERT_ID sy-vline
WA_UPS_S_OD_MEASUREMENT_RDG_UPD_STR-AUTH_INS sy-vline
WA_UPS_S_OD_MEASUREMENT_RDG_UPD_STR-AUTH_DIS sy-vline
WA_UPS_S_OD_MEASUREMENT_RDG_UPD_STR-AUTH_CHG sy-vline
WA_UPS_S_OD_MEASUREMENT_RDG_UPD_STR-AUTH_DEL sy-vline
WA_UPS_S_OD_MEASUREMENT_RDG_UPD_STR-PPA_LOCK sy-vline
WA_UPS_S_OD_MEASUREMENT_RDG_UPD_STR-PPA_REQUESTER_FLAG sy-vline
WA_UPS_S_OD_MEASUREMENT_RDG_UPD_STR-REQUESTER sy-vline
WA_UPS_S_OD_MEASUREMENT_RDG_UPD_STR-TRNSP_NO sy-vline
WA_UPS_S_OD_MEASUREMENT_RDG_UPD_STR-TRNSP_REF_NO sy-vline
WA_UPS_S_OD_MEASUREMENT_RDG_UPD_STR-TKT_NO sy-vline
WA_UPS_S_OD_MEASUREMENT_RDG_UPD_STR-TRANSP_NAME sy-vline
WA_UPS_S_OD_MEASUREMENT_RDG_UPD_STR-TO_PROD_NETWORK sy-vline
WA_UPS_S_OD_MEASUREMENT_RDG_UPD_STR-TO_NETOBJ_TYPE sy-vline
WA_UPS_S_OD_MEASUREMENT_RDG_UPD_STR-TO_NETOBJ_TY_DES sy-vline
WA_UPS_S_OD_MEASUREMENT_RDG_UPD_STR-TO_NETWORK_OBJ sy-vline
WA_UPS_S_OD_MEASUREMENT_RDG_UPD_STR-LD_OIL_WO_RECOV sy-vline
WA_UPS_S_OD_MEASUREMENT_RDG_UPD_STR-ORIGINATING_MP sy-vline
WA_UPS_S_OD_MEASUREMENT_RDG_UPD_STR-QTY_CATEGORY sy-vline
WA_UPS_S_OD_MEASUREMENT_RDG_UPD_STR-FDCMEASUREMENTRAWSET sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.