ABAP Select data from SAP table UPOS_UDM_WC_VOL_FILE_IMPORT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP UPOS_UDM_WC_VOL_FILE_IMPORT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to UPOS_UDM_WC_VOL_FILE_IMPORT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the UPOS_UDM_WC_VOL_FILE_IMPORT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_UPOS_UDM_WC_VOL_FILE_IMPORT TYPE STANDARD TABLE OF UPOS_UDM_WC_VOL_FILE_IMPORT,
      WA_UPOS_UDM_WC_VOL_FILE_IMPORT TYPE UPOS_UDM_WC_VOL_FILE_IMPORT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <UPOS_UDM_WC_VOL_FILE_IMPORT> TYPE UPOS_UDM_WC_VOL_FILE_IMPORT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_UPOS_UDM_WC_VOL_FILE_IMPORT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM UPOS_UDM_WC_VOL_FILE_IMPORT
  INTO TABLE IT_UPOS_UDM_WC_VOL_FILE_IMPORT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM UPOS_UDM_WC_VOL_FILE_IMPORT
*  INTO TABLE @DATA(IT_UPOS_UDM_WC_VOL_FILE_IMPORT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_UPOS_UDM_WC_VOL_FILE_IMPORT INDEX 1 INTO DATA(WA_UPOS_UDM_WC_VOL_FILE_IMPORT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_UPOS_UDM_WC_VOL_FILE_IMPORT ASSIGNING <UPOS_UDM_WC_VOL_FILE_IMPORT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<UPOS_UDM_WC_VOL_FILE_IMPORT>-RECORD_TYPE = 1.
<UPOS_UDM_WC_VOL_FILE_IMPORT>-NET_ID = 1.
<UPOS_UDM_WC_VOL_FILE_IMPORT>-NODE_ID = 1.
<UPOS_UDM_WC_VOL_FILE_IMPORT>-NETOBJ_TYP = 1.
<UPOS_UDM_WC_VOL_FILE_IMPORT>-MEAS_DATE = 1.
ENDLOOP.

LOOP AT IT_UPOS_UDM_WC_VOL_FILE_IMPORT INTO WA_UPOS_UDM_WC_VOL_FILE_IMPORT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_UPOS_UDM_WC_VOL_FILE_IMPORT-MEAS_TIME, sy-vline,
WA_UPOS_UDM_WC_VOL_FILE_IMPORT-ALLOCATION_MAT, sy-vline,
WA_UPOS_UDM_WC_VOL_FILE_IMPORT-QTY_TYPE, sy-vline,
WA_UPOS_UDM_WC_VOL_FILE_IMPORT-ALLOC_TYPE, sy-vline,
WA_UPOS_UDM_WC_VOL_FILE_IMPORT-FREQUENCY, sy-vline,
WA_UPOS_UDM_WC_VOL_FILE_IMPORT-MEDIUM, sy-vline.
ENDLOOP. *Add any further fields from structure WA_UPOS_UDM_WC_VOL_FILE_IMPORT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_UPOS_UDM_WC_VOL_FILE_IMPORT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_UPOS_UDM_WC_VOL_FILE_IMPORT INTO WA_UPOS_UDM_WC_VOL_FILE_IMPORT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit GHONO, internal->external for field NET_ID CALL FUNCTION 'CONVERSION_EXIT_GHONO_OUTPUT' EXPORTING input = WA_UPOS_UDM_WC_VOL_FILE_IMPORT-NET_ID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_UPOS_UDM_WC_VOL_FILE_IMPORT-NET_ID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TPLNR, internal->external for field NODE_ID CALL FUNCTION 'CONVERSION_EXIT_TPLNR_OUTPUT' EXPORTING input = WA_UPOS_UDM_WC_VOL_FILE_IMPORT-NODE_ID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_UPOS_UDM_WC_VOL_FILE_IMPORT-NODE_ID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field ALLOCATION_MAT CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_UPOS_UDM_WC_VOL_FILE_IMPORT-ALLOCATION_MAT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_UPOS_UDM_WC_VOL_FILE_IMPORT-ALLOCATION_MAT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GHONO, internal->external for field TO_PROD_NETWORK CALL FUNCTION 'CONVERSION_EXIT_GHONO_OUTPUT' EXPORTING input = WA_UPOS_UDM_WC_VOL_FILE_IMPORT-TO_PROD_NETWORK IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_UPOS_UDM_WC_VOL_FILE_IMPORT-TO_PROD_NETWORK.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GHONO, internal->external for field TO_NETWORK_OBJ CALL FUNCTION 'CONVERSION_EXIT_GHONO_OUTPUT' EXPORTING input = WA_UPOS_UDM_WC_VOL_FILE_IMPORT-TO_NETWORK_OBJ IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_UPOS_UDM_WC_VOL_FILE_IMPORT-TO_NETWORK_OBJ.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field TRNSP_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_UPOS_UDM_WC_VOL_FILE_IMPORT-TRNSP_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_UPOS_UDM_WC_VOL_FILE_IMPORT-TRNSP_NO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GHONO, internal->external for field ORIGINATING_MP CALL FUNCTION 'CONVERSION_EXIT_GHONO_OUTPUT' EXPORTING input = WA_UPOS_UDM_WC_VOL_FILE_IMPORT-ORIGINATING_MP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_UPOS_UDM_WC_VOL_FILE_IMPORT-ORIGINATING_MP.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_UPOS_UDM_WC_VOL_FILE_IMPORT_STR,
RECORD_TYPE TYPE STRING,
NET_ID TYPE STRING,
NODE_ID TYPE STRING,
NETOBJ_TYP TYPE STRING,
MEAS_DATE TYPE STRING,
MEAS_TIME TYPE STRING,
ALLOCATION_MAT TYPE STRING,
QTY_TYPE TYPE STRING,
ALLOC_TYPE TYPE STRING,
FREQUENCY TYPE STRING,
MEDIUM TYPE STRING,
MEAS_CAT_ID TYPE STRING,
MDC_PARAMETER TYPE STRING,
MDC_VALUE TYPE STRING,
TO_PROD_NETWORK TYPE STRING,
TO_NETOBJ_TYPE TYPE STRING,
TO_NETWORK_OBJ TYPE STRING,
LD_OIL_WO_RECOV TYPE STRING,
TRNSP_NO TYPE STRING,
TRNSP_REF_NO TYPE STRING,
TKT_NO TYPE STRING,
ORIGINATING_MP TYPE STRING,
ROW_ID TYPE STRING,END OF T_EKKO_STR. DATA: WA_UPOS_UDM_WC_VOL_FILE_IMPORT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_UPOS_UDM_WC_VOL_FILE_IMPORT_STR-RECORD_TYPE sy-vline
WA_UPOS_UDM_WC_VOL_FILE_IMPORT_STR-NET_ID sy-vline
WA_UPOS_UDM_WC_VOL_FILE_IMPORT_STR-NODE_ID sy-vline
WA_UPOS_UDM_WC_VOL_FILE_IMPORT_STR-NETOBJ_TYP sy-vline
WA_UPOS_UDM_WC_VOL_FILE_IMPORT_STR-MEAS_DATE sy-vline
WA_UPOS_UDM_WC_VOL_FILE_IMPORT_STR-MEAS_TIME sy-vline
WA_UPOS_UDM_WC_VOL_FILE_IMPORT_STR-ALLOCATION_MAT sy-vline
WA_UPOS_UDM_WC_VOL_FILE_IMPORT_STR-QTY_TYPE sy-vline
WA_UPOS_UDM_WC_VOL_FILE_IMPORT_STR-ALLOC_TYPE sy-vline
WA_UPOS_UDM_WC_VOL_FILE_IMPORT_STR-FREQUENCY sy-vline
WA_UPOS_UDM_WC_VOL_FILE_IMPORT_STR-MEDIUM sy-vline
WA_UPOS_UDM_WC_VOL_FILE_IMPORT_STR-MEAS_CAT_ID sy-vline
WA_UPOS_UDM_WC_VOL_FILE_IMPORT_STR-MDC_PARAMETER sy-vline
WA_UPOS_UDM_WC_VOL_FILE_IMPORT_STR-MDC_VALUE sy-vline
WA_UPOS_UDM_WC_VOL_FILE_IMPORT_STR-TO_PROD_NETWORK sy-vline
WA_UPOS_UDM_WC_VOL_FILE_IMPORT_STR-TO_NETOBJ_TYPE sy-vline
WA_UPOS_UDM_WC_VOL_FILE_IMPORT_STR-TO_NETWORK_OBJ sy-vline
WA_UPOS_UDM_WC_VOL_FILE_IMPORT_STR-LD_OIL_WO_RECOV sy-vline
WA_UPOS_UDM_WC_VOL_FILE_IMPORT_STR-TRNSP_NO sy-vline
WA_UPOS_UDM_WC_VOL_FILE_IMPORT_STR-TRNSP_REF_NO sy-vline
WA_UPOS_UDM_WC_VOL_FILE_IMPORT_STR-TKT_NO sy-vline
WA_UPOS_UDM_WC_VOL_FILE_IMPORT_STR-ORIGINATING_MP sy-vline
WA_UPOS_UDM_WC_VOL_FILE_IMPORT_STR-ROW_ID sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.