ABAP Select data from SAP table UPOEXT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP UPOEXT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to UPOEXT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the UPOEXT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_UPOEXT TYPE STANDARD TABLE OF UPOEXT,
      WA_UPOEXT TYPE UPOEXT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <UPOEXT> TYPE UPOEXT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_UPOEXT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM UPOEXT
  INTO TABLE IT_UPOEXT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM UPOEXT
*  INTO TABLE @DATA(IT_UPOEXT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_UPOEXT INDEX 1 INTO DATA(WA_UPOEXT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_UPOEXT ASSIGNING <UPOEXT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<UPOEXT>-MANDT = 1.
<UPOEXT>-EBELN = 1.
<UPOEXT>-EBELP = 1.
<UPOEXT>-DUMMY1 = 1.
<UPOEXT>-TM_CTRL_KEY = 1.
ENDLOOP.

LOOP AT IT_UPOEXT INTO WA_UPOEXT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_UPOEXT-MSR_PO_TYPE, sy-vline,
WA_UPOEXT-DUMMY5, sy-vline,
WA_UPOEXT-PS_PA_ID_HDR, sy-vline,
WA_UPOEXT-PS_PA_CLNG_HDR, sy-vline,
WA_UPOEXT-DUMMY2, sy-vline,
WA_UPOEXT-FASTPAY, sy-vline.
ENDLOOP. *Add any further fields from structure WA_UPOEXT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_UPOEXT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_UPOEXT INTO WA_UPOEXT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field EBELN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_UPOEXT-EBELN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_UPOEXT-EBELN.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_UPOEXT_STR,
MANDT TYPE STRING,
EBELN TYPE STRING,
EBELP TYPE STRING,
DUMMY1 TYPE STRING,
TM_CTRL_KEY TYPE STRING,
MSR_PO_TYPE TYPE STRING,
DUMMY5 TYPE STRING,
PS_PA_ID_HDR TYPE STRING,
PS_PA_CLNG_HDR TYPE STRING,
DUMMY2 TYPE STRING,
FASTPAY TYPE STRING,
PPA_EX_IND TYPE STRING,
PEROP_BEG TYPE STRING,
PEROP_END TYPE STRING,
PS_INFU_IND TYPE STRING,
PS_PA_ID TYPE STRING,
PS_PA_MIN_FEE TYPE STRING,
PS_PA_MAX_FEE TYPE STRING,
PS_PA_GS_BLW TYPE STRING,
PS_PA_GS_ABV TYPE STRING,
PS_PA_CLNG_AMT TYPE STRING,
PS_PA_TOTL_AMT TYPE STRING,
PS_PA_NTE_IND TYPE STRING,
PS_PA_NSP_IND TYPE STRING,
PS_PA_COMP_KEY TYPE STRING,
PS_PA_COMP_TYPE TYPE STRING,
DUMMY3 TYPE STRING,
DUMMY4 TYPE STRING,
_DATAAGING TYPE STRING,
UPDATE TYPE STRING,END OF T_EKKO_STR. DATA: WA_UPOEXT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_UPOEXT_STR-MANDT sy-vline
WA_UPOEXT_STR-EBELN sy-vline
WA_UPOEXT_STR-EBELP sy-vline
WA_UPOEXT_STR-DUMMY1 sy-vline
WA_UPOEXT_STR-TM_CTRL_KEY sy-vline
WA_UPOEXT_STR-MSR_PO_TYPE sy-vline
WA_UPOEXT_STR-DUMMY5 sy-vline
WA_UPOEXT_STR-PS_PA_ID_HDR sy-vline
WA_UPOEXT_STR-PS_PA_CLNG_HDR sy-vline
WA_UPOEXT_STR-DUMMY2 sy-vline
WA_UPOEXT_STR-FASTPAY sy-vline
WA_UPOEXT_STR-PPA_EX_IND sy-vline
WA_UPOEXT_STR-PEROP_BEG sy-vline
WA_UPOEXT_STR-PEROP_END sy-vline
WA_UPOEXT_STR-PS_INFU_IND sy-vline
WA_UPOEXT_STR-PS_PA_ID sy-vline
WA_UPOEXT_STR-PS_PA_MIN_FEE sy-vline
WA_UPOEXT_STR-PS_PA_MAX_FEE sy-vline
WA_UPOEXT_STR-PS_PA_GS_BLW sy-vline
WA_UPOEXT_STR-PS_PA_GS_ABV sy-vline
WA_UPOEXT_STR-PS_PA_CLNG_AMT sy-vline
WA_UPOEXT_STR-PS_PA_TOTL_AMT sy-vline
WA_UPOEXT_STR-PS_PA_NTE_IND sy-vline
WA_UPOEXT_STR-PS_PA_NSP_IND sy-vline
WA_UPOEXT_STR-PS_PA_COMP_KEY sy-vline
WA_UPOEXT_STR-PS_PA_COMP_TYPE sy-vline
WA_UPOEXT_STR-DUMMY3 sy-vline
WA_UPOEXT_STR-DUMMY4 sy-vline
WA_UPOEXT_STR-_DATAAGING sy-vline
WA_UPOEXT_STR-UPDATE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.