ABAP Select data from SAP table UPE_YS_ATTR_ABC into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP UPE_YS_ATTR_ABC table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to UPE_YS_ATTR_ABC. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the UPE_YS_ATTR_ABC table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_UPE_YS_ATTR_ABC TYPE STANDARD TABLE OF UPE_YS_ATTR_ABC,
      WA_UPE_YS_ATTR_ABC TYPE UPE_YS_ATTR_ABC,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <UPE_YS_ATTR_ABC> TYPE UPE_YS_ATTR_ABC.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_UPE_YS_ATTR_ABC.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM UPE_YS_ATTR_ABC
  INTO TABLE IT_UPE_YS_ATTR_ABC.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM UPE_YS_ATTR_ABC
*  INTO TABLE @DATA(IT_UPE_YS_ATTR_ABC2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_UPE_YS_ATTR_ABC INDEX 1 INTO DATA(WA_UPE_YS_ATTR_ABC2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_UPE_YS_ATTR_ABC ASSIGNING <UPE_YS_ATTR_ABC>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<UPE_YS_ATTR_ABC>-AREA = 1.
<UPE_YS_ATTR_ABC>-CHANM = 1.
<UPE_YS_ATTR_ABC>-ATRNM = 1.
<UPE_YS_ATTR_ABC>-IOBJTP = 1.
<UPE_YS_ATTR_ABC>-KYFTP = 1.
ENDLOOP.

LOOP AT IT_UPE_YS_ATTR_ABC INTO WA_UPE_YS_ATTR_ABC.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_UPE_YS_ATTR_ABC-DATATP, sy-vline,
WA_UPE_YS_ATTR_ABC-INTTP, sy-vline,
WA_UPE_YS_ATTR_ABC-INTLEN, sy-vline,
WA_UPE_YS_ATTR_ABC-LENG, sy-vline,
WA_UPE_YS_ATTR_ABC-DECIMALS, sy-vline,
WA_UPE_YS_ATTR_ABC-OUTPUTLEN, sy-vline.
ENDLOOP. *Add any further fields from structure WA_UPE_YS_ATTR_ABC you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_UPE_YS_ATTR_ABC TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_UPE_YS_ATTR_ABC INTO WA_UPE_YS_ATTR_ABC. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit DTYPE, internal->external for field DATATP CALL FUNCTION 'CONVERSION_EXIT_DTYPE_OUTPUT' EXPORTING input = WA_UPE_YS_ATTR_ABC-DATATP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_UPE_YS_ATTR_ABC-DATATP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field FIXUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_UPE_YS_ATTR_ABC-FIXUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_UPE_YS_ATTR_ABC-FIXUNIT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_UPE_YS_ATTR_ABC_STR,
AREA TYPE STRING,
CHANM TYPE STRING,
ATRNM TYPE STRING,
IOBJTP TYPE STRING,
KYFTP TYPE STRING,
DATATP TYPE STRING,
INTTP TYPE STRING,
INTLEN TYPE STRING,
LENG TYPE STRING,
DECIMALS TYPE STRING,
OUTPUTLEN TYPE STRING,
TXTSH TYPE STRING,
TXTLG TYPE STRING,
FIXCUKY TYPE STRING,
FIXUNIT TYPE STRING,
FIXUNITEXT TYPE STRING,
KYFDECIM TYPE STRING,
KYFPRSNT TYPE STRING,
UNINM TYPE STRING,
LOWERCASE TYPE STRING,END OF T_EKKO_STR. DATA: WA_UPE_YS_ATTR_ABC_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_UPE_YS_ATTR_ABC_STR-AREA sy-vline
WA_UPE_YS_ATTR_ABC_STR-CHANM sy-vline
WA_UPE_YS_ATTR_ABC_STR-ATRNM sy-vline
WA_UPE_YS_ATTR_ABC_STR-IOBJTP sy-vline
WA_UPE_YS_ATTR_ABC_STR-KYFTP sy-vline
WA_UPE_YS_ATTR_ABC_STR-DATATP sy-vline
WA_UPE_YS_ATTR_ABC_STR-INTTP sy-vline
WA_UPE_YS_ATTR_ABC_STR-INTLEN sy-vline
WA_UPE_YS_ATTR_ABC_STR-LENG sy-vline
WA_UPE_YS_ATTR_ABC_STR-DECIMALS sy-vline
WA_UPE_YS_ATTR_ABC_STR-OUTPUTLEN sy-vline
WA_UPE_YS_ATTR_ABC_STR-TXTSH sy-vline
WA_UPE_YS_ATTR_ABC_STR-TXTLG sy-vline
WA_UPE_YS_ATTR_ABC_STR-FIXCUKY sy-vline
WA_UPE_YS_ATTR_ABC_STR-FIXUNIT sy-vline
WA_UPE_YS_ATTR_ABC_STR-FIXUNITEXT sy-vline
WA_UPE_YS_ATTR_ABC_STR-KYFDECIM sy-vline
WA_UPE_YS_ATTR_ABC_STR-KYFPRSNT sy-vline
WA_UPE_YS_ATTR_ABC_STR-UNINM sy-vline
WA_UPE_YS_ATTR_ABC_STR-LOWERCASE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.