ABAP Select data from SAP table UPB_CW_CCSE into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP UPB_CW_CCSE table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to UPB_CW_CCSE. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the UPB_CW_CCSE table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_UPB_CW_CCSE TYPE STANDARD TABLE OF UPB_CW_CCSE,
      WA_UPB_CW_CCSE TYPE UPB_CW_CCSE,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <UPB_CW_CCSE> TYPE UPB_CW_CCSE.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_UPB_CW_CCSE.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM UPB_CW_CCSE
  INTO TABLE IT_UPB_CW_CCSE.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM UPB_CW_CCSE
*  INTO TABLE @DATA(IT_UPB_CW_CCSE2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_UPB_CW_CCSE INDEX 1 INTO DATA(WA_UPB_CW_CCSE2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_UPB_CW_CCSE ASSIGNING <UPB_CW_CCSE>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<UPB_CW_CCSE>-MANDT = 1.
<UPB_CW_CCSE>-CCE = 1.
<UPB_CW_CCSE>-CCSE = 1.
<UPB_CW_CCSE>-CCS = 1.
<UPB_CW_CCSE>-PREV = 1.
ENDLOOP.

LOOP AT IT_UPB_CW_CCSE INTO WA_UPB_CW_CCSE.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_UPB_CW_CCSE-ED, sy-vline,
WA_UPB_CW_CCSE-ES, sy-vline,
WA_UPB_CW_CCSE-EP, sy-vline,
WA_UPB_CW_CCSE-COUNTER, sy-vline,
WA_UPB_CW_CCSE-UNAME, sy-vline,
WA_UPB_CW_CCSE-AEDTM, sy-vline.
ENDLOOP. *Add any further fields from structure WA_UPB_CW_CCSE you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_UPB_CW_CCSE TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_UPB_CW_CCSE INTO WA_UPB_CW_CCSE. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_UPB_CW_CCSE_STR,
MANDT TYPE STRING,
CCE TYPE STRING,
CCSE TYPE STRING,
CCS TYPE STRING,
PREV TYPE STRING,
ED TYPE STRING,
ES TYPE STRING,
EP TYPE STRING,
COUNTER TYPE STRING,
UNAME TYPE STRING,
AEDTM TYPE STRING,
ATIME TYPE STRING,
RFCDEST TYPE STRING,END OF T_EKKO_STR. DATA: WA_UPB_CW_CCSE_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_UPB_CW_CCSE_STR-MANDT sy-vline
WA_UPB_CW_CCSE_STR-CCE sy-vline
WA_UPB_CW_CCSE_STR-CCSE sy-vline
WA_UPB_CW_CCSE_STR-CCS sy-vline
WA_UPB_CW_CCSE_STR-PREV sy-vline
WA_UPB_CW_CCSE_STR-ED sy-vline
WA_UPB_CW_CCSE_STR-ES sy-vline
WA_UPB_CW_CCSE_STR-EP sy-vline
WA_UPB_CW_CCSE_STR-COUNTER sy-vline
WA_UPB_CW_CCSE_STR-UNAME sy-vline
WA_UPB_CW_CCSE_STR-AEDTM sy-vline
WA_UPB_CW_CCSE_STR-ATIME sy-vline
WA_UPB_CW_CCSE_STR-RFCDEST sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.