ABAP Select data from SAP table UNS_UNSC01 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP UNS_UNSC01 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to UNS_UNSC01. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the UNS_UNSC01 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_UNS_UNSC01 TYPE STANDARD TABLE OF UNS_UNSC01,
      WA_UNS_UNSC01 TYPE UNS_UNSC01,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <UNS_UNSC01> TYPE UNS_UNSC01.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_UNS_UNSC01.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM UNS_UNSC01
  INTO TABLE IT_UNS_UNSC01.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM UNS_UNSC01
*  INTO TABLE @DATA(IT_UNS_UNSC012).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_UNS_UNSC01 INDEX 1 INTO DATA(WA_UNS_UNSC012).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_UNS_UNSC01 ASSIGNING <UNS_UNSC01>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<UNS_UNSC01>-LED = 1.
<UNS_UNSC01>-UC = 1.
<UNS_UNSC01>-ORGSYS = 1.
<UNS_UNSC01>-PROG = 1.
<UNS_UNSC01>-INCL = 1.
ENDLOOP.

LOOP AT IT_UNS_UNSC01 INTO WA_UNS_UNSC01.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_UNS_UNSC01-LINE, sy-vline,
WA_UNS_UNSC01-CODE, sy-vline,
WA_UNS_UNSC01-MESS, sy-vline,
WA_UNS_UNSC01-AUT, sy-vline,
WA_UNS_UNSC01-DEV, sy-vline,
WA_UNS_UNSC01-DEVAUT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_UNS_UNSC01 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_UNS_UNSC01 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_UNS_UNSC01 INTO WA_UNS_UNSC01. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_UNS_UNSC01_STR,
LED TYPE STRING,
UC TYPE STRING,
ORGSYS TYPE STRING,
PROG TYPE STRING,
INCL TYPE STRING,
LINE TYPE STRING,
CODE TYPE STRING,
MESS TYPE STRING,
AUT TYPE STRING,
DEV TYPE STRING,
DEVAUT TYPE STRING,
COMPONENT TYPE STRING,
ERR_NUMB TYPE STRING,
ERR_KIND TYPE STRING,
TINDEX TYPE STRING,
OBJ TYPE STRING,
OBJ_N TYPE STRING,
TXT_TAB TYPE STRING,END OF T_EKKO_STR. DATA: WA_UNS_UNSC01_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_UNS_UNSC01_STR-LED sy-vline
WA_UNS_UNSC01_STR-UC sy-vline
WA_UNS_UNSC01_STR-ORGSYS sy-vline
WA_UNS_UNSC01_STR-PROG sy-vline
WA_UNS_UNSC01_STR-INCL sy-vline
WA_UNS_UNSC01_STR-LINE sy-vline
WA_UNS_UNSC01_STR-CODE sy-vline
WA_UNS_UNSC01_STR-MESS sy-vline
WA_UNS_UNSC01_STR-AUT sy-vline
WA_UNS_UNSC01_STR-DEV sy-vline
WA_UNS_UNSC01_STR-DEVAUT sy-vline
WA_UNS_UNSC01_STR-COMPONENT sy-vline
WA_UNS_UNSC01_STR-ERR_NUMB sy-vline
WA_UNS_UNSC01_STR-ERR_KIND sy-vline
WA_UNS_UNSC01_STR-TINDEX sy-vline
WA_UNS_UNSC01_STR-OBJ sy-vline
WA_UNS_UNSC01_STR-OBJ_N sy-vline
WA_UNS_UNSC01_STR-TXT_TAB sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.