ABAP Select data from SAP table UMM_YS_CUST_COCKPITDATA into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP UMM_YS_CUST_COCKPITDATA table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to UMM_YS_CUST_COCKPITDATA. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the UMM_YS_CUST_COCKPITDATA table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_UMM_YS_CUST_COCKPITDATA TYPE STANDARD TABLE OF UMM_YS_CUST_COCKPITDATA,
      WA_UMM_YS_CUST_COCKPITDATA TYPE UMM_YS_CUST_COCKPITDATA,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <UMM_YS_CUST_COCKPITDATA> TYPE UMM_YS_CUST_COCKPITDATA.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_UMM_YS_CUST_COCKPITDATA.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM UMM_YS_CUST_COCKPITDATA
  INTO TABLE IT_UMM_YS_CUST_COCKPITDATA.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM UMM_YS_CUST_COCKPITDATA
*  INTO TABLE @DATA(IT_UMM_YS_CUST_COCKPITDATA2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_UMM_YS_CUST_COCKPITDATA INDEX 1 INTO DATA(WA_UMM_YS_CUST_COCKPITDATA2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_UMM_YS_CUST_COCKPITDATA ASSIGNING <UMM_YS_CUST_COCKPITDATA>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<UMM_YS_CUST_COCKPITDATA>-CONAME = 1.
<UMM_YS_CUST_COCKPITDATA>-NOWA = 1.
<UMM_YS_CUST_COCKPITDATA>-STATUS = 1.
<UMM_YS_CUST_COCKPITDATA>-DSTATUS = 1.
<UMM_YS_CUST_COCKPITDATA>-PARALLEL = 1.
ENDLOOP.

LOOP AT IT_UMM_YS_CUST_COCKPITDATA INTO WA_UMM_YS_CUST_COCKPITDATA.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_UMM_YS_CUST_COCKPITDATA-LTXT, sy-vline,
WA_UMM_YS_CUST_COCKPITDATA-MTXT, sy-vline,
WA_UMM_YS_CUST_COCKPITDATA-STXT, sy-vline,
WA_UMM_YS_CUST_COCKPITDATA-ATXT, sy-vline,
WA_UMM_YS_CUST_COCKPITDATA-PERIV, sy-vline,
WA_UMM_YS_CUST_COCKPITDATA-INIT_CURVAR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_UMM_YS_CUST_COCKPITDATA you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_UMM_YS_CUST_COCKPITDATA TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_UMM_YS_CUST_COCKPITDATA INTO WA_UMM_YS_CUST_COCKPITDATA. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_UMM_YS_CUST_COCKPITDATA_STR,
CONAME TYPE STRING,
NOWA TYPE STRING,
STATUS TYPE STRING,
DSTATUS TYPE STRING,
PARALLEL TYPE STRING,
LTXT TYPE STRING,
MTXT TYPE STRING,
STXT TYPE STRING,
ATXT TYPE STRING,
PERIV TYPE STRING,
INIT_CURVAR TYPE STRING,
INIT_TARVAR TYPE STRING,
PERIODICITY TYPE STRING,
BW_BUFFER TYPE STRING,
DATE_FORMAT TYPE STRING,
USER_DEP_BUF TYPE STRING,END OF T_EKKO_STR. DATA: WA_UMM_YS_CUST_COCKPITDATA_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_UMM_YS_CUST_COCKPITDATA_STR-CONAME sy-vline
WA_UMM_YS_CUST_COCKPITDATA_STR-NOWA sy-vline
WA_UMM_YS_CUST_COCKPITDATA_STR-STATUS sy-vline
WA_UMM_YS_CUST_COCKPITDATA_STR-DSTATUS sy-vline
WA_UMM_YS_CUST_COCKPITDATA_STR-PARALLEL sy-vline
WA_UMM_YS_CUST_COCKPITDATA_STR-LTXT sy-vline
WA_UMM_YS_CUST_COCKPITDATA_STR-MTXT sy-vline
WA_UMM_YS_CUST_COCKPITDATA_STR-STXT sy-vline
WA_UMM_YS_CUST_COCKPITDATA_STR-ATXT sy-vline
WA_UMM_YS_CUST_COCKPITDATA_STR-PERIV sy-vline
WA_UMM_YS_CUST_COCKPITDATA_STR-INIT_CURVAR sy-vline
WA_UMM_YS_CUST_COCKPITDATA_STR-INIT_TARVAR sy-vline
WA_UMM_YS_CUST_COCKPITDATA_STR-PERIODICITY sy-vline
WA_UMM_YS_CUST_COCKPITDATA_STR-BW_BUFFER sy-vline
WA_UMM_YS_CUST_COCKPITDATA_STR-DATE_FORMAT sy-vline
WA_UMM_YS_CUST_COCKPITDATA_STR-USER_DEP_BUF sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.