ABAP Select data from SAP table UMM_S_RMNIWE90_01_GRID into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP UMM_S_RMNIWE90_01_GRID table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to UMM_S_RMNIWE90_01_GRID. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the UMM_S_RMNIWE90_01_GRID table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_UMM_S_RMNIWE90_01_GRID TYPE STANDARD TABLE OF UMM_S_RMNIWE90_01_GRID,
      WA_UMM_S_RMNIWE90_01_GRID TYPE UMM_S_RMNIWE90_01_GRID,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <UMM_S_RMNIWE90_01_GRID> TYPE UMM_S_RMNIWE90_01_GRID.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_UMM_S_RMNIWE90_01_GRID.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM UMM_S_RMNIWE90_01_GRID
  INTO TABLE IT_UMM_S_RMNIWE90_01_GRID.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM UMM_S_RMNIWE90_01_GRID
*  INTO TABLE @DATA(IT_UMM_S_RMNIWE90_01_GRID2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_UMM_S_RMNIWE90_01_GRID INDEX 1 INTO DATA(WA_UMM_S_RMNIWE90_01_GRID2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_UMM_S_RMNIWE90_01_GRID ASSIGNING <UMM_S_RMNIWE90_01_GRID>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<UMM_S_RMNIWE90_01_GRID>-BWKEY = 1.
<UMM_S_RMNIWE90_01_GRID>-KONTO = 1.
<UMM_S_RMNIWE90_01_GRID>-MATNR = 1.
<UMM_S_RMNIWE90_01_GRID>-BWTAR = 1.
<UMM_S_RMNIWE90_01_GRID>-MAKTX = 1.
ENDLOOP.

LOOP AT IT_UMM_S_RMNIWE90_01_GRID INTO WA_UMM_S_RMNIWE90_01_GRID.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_UMM_S_RMNIWE90_01_GRID-LBKUM, sy-vline,
WA_UMM_S_RMNIWE90_01_GRID-MEINS, sy-vline,
WA_UMM_S_RMNIWE90_01_GRID-WAERS, sy-vline,
WA_UMM_S_RMNIWE90_01_GRID-SALK3, sy-vline,
WA_UMM_S_RMNIWE90_01_GRID-WERT1, sy-vline,
WA_UMM_S_RMNIWE90_01_GRID-WERT2, sy-vline.
ENDLOOP. *Add any further fields from structure WA_UMM_S_RMNIWE90_01_GRID you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_UMM_S_RMNIWE90_01_GRID TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_UMM_S_RMNIWE90_01_GRID INTO WA_UMM_S_RMNIWE90_01_GRID. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field KONTO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_UMM_S_RMNIWE90_01_GRID-KONTO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_UMM_S_RMNIWE90_01_GRID-KONTO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_UMM_S_RMNIWE90_01_GRID-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_UMM_S_RMNIWE90_01_GRID-MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MEINS CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_UMM_S_RMNIWE90_01_GRID-MEINS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_UMM_S_RMNIWE90_01_GRID-MEINS.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_UMM_S_RMNIWE90_01_GRID_STR,
BWKEY TYPE STRING,
KONTO TYPE STRING,
MATNR TYPE STRING,
BWTAR TYPE STRING,
MAKTX TYPE STRING,
LBKUM TYPE STRING,
MEINS TYPE STRING,
WAERS TYPE STRING,
SALK3 TYPE STRING,
WERT1 TYPE STRING,
WERT2 TYPE STRING,
WERT3 TYPE STRING,
WERT4 TYPE STRING,
WERT5 TYPE STRING,
WERT6 TYPE STRING,
BWERT TYPE STRING,END OF T_EKKO_STR. DATA: WA_UMM_S_RMNIWE90_01_GRID_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_UMM_S_RMNIWE90_01_GRID_STR-BWKEY sy-vline
WA_UMM_S_RMNIWE90_01_GRID_STR-KONTO sy-vline
WA_UMM_S_RMNIWE90_01_GRID_STR-MATNR sy-vline
WA_UMM_S_RMNIWE90_01_GRID_STR-BWTAR sy-vline
WA_UMM_S_RMNIWE90_01_GRID_STR-MAKTX sy-vline
WA_UMM_S_RMNIWE90_01_GRID_STR-LBKUM sy-vline
WA_UMM_S_RMNIWE90_01_GRID_STR-MEINS sy-vline
WA_UMM_S_RMNIWE90_01_GRID_STR-WAERS sy-vline
WA_UMM_S_RMNIWE90_01_GRID_STR-SALK3 sy-vline
WA_UMM_S_RMNIWE90_01_GRID_STR-WERT1 sy-vline
WA_UMM_S_RMNIWE90_01_GRID_STR-WERT2 sy-vline
WA_UMM_S_RMNIWE90_01_GRID_STR-WERT3 sy-vline
WA_UMM_S_RMNIWE90_01_GRID_STR-WERT4 sy-vline
WA_UMM_S_RMNIWE90_01_GRID_STR-WERT5 sy-vline
WA_UMM_S_RMNIWE90_01_GRID_STR-WERT6 sy-vline
WA_UMM_S_RMNIWE90_01_GRID_STR-BWERT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.