ABAP Select data from SAP table UMB_YS_MEASINIT_PRINT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP UMB_YS_MEASINIT_PRINT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to UMB_YS_MEASINIT_PRINT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the UMB_YS_MEASINIT_PRINT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_UMB_YS_MEASINIT_PRINT TYPE STANDARD TABLE OF UMB_YS_MEASINIT_PRINT,
      WA_UMB_YS_MEASINIT_PRINT TYPE UMB_YS_MEASINIT_PRINT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <UMB_YS_MEASINIT_PRINT> TYPE UMB_YS_MEASINIT_PRINT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_UMB_YS_MEASINIT_PRINT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM UMB_YS_MEASINIT_PRINT
  INTO TABLE IT_UMB_YS_MEASINIT_PRINT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM UMB_YS_MEASINIT_PRINT
*  INTO TABLE @DATA(IT_UMB_YS_MEASINIT_PRINT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_UMB_YS_MEASINIT_PRINT INDEX 1 INTO DATA(WA_UMB_YS_MEASINIT_PRINT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_UMB_YS_MEASINIT_PRINT ASSIGNING <UMB_YS_MEASINIT_PRINT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<UMB_YS_MEASINIT_PRINT>-SCARD_STXT = 1.
<UMB_YS_MEASINIT_PRINT>-STRAT_LTXT = 1.
<UMB_YS_MEASINIT_PRINT>-PERS_LTXT = 1.
<UMB_YS_MEASINIT_PRINT>-OBJ_LTXT = 1.
<UMB_YS_MEASINIT_PRINT>-MEASINIT = 1.
ENDLOOP.

LOOP AT IT_UMB_YS_MEASINIT_PRINT INTO WA_UMB_YS_MEASINIT_PRINT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_UMB_YS_MEASINIT_PRINT-MEASINIT_LTXT, sy-vline,
WA_UMB_YS_MEASINIT_PRINT-OWNER, sy-vline,
WA_UMB_YS_MEASINIT_PRINT-STATUS, sy-vline,
WA_UMB_YS_MEASINIT_PRINT-COL01, sy-vline,
WA_UMB_YS_MEASINIT_PRINT-COL02, sy-vline,
WA_UMB_YS_MEASINIT_PRINT-COL03, sy-vline.
ENDLOOP. *Add any further fields from structure WA_UMB_YS_MEASINIT_PRINT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_UMB_YS_MEASINIT_PRINT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_UMB_YS_MEASINIT_PRINT INTO WA_UMB_YS_MEASINIT_PRINT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_UMB_YS_MEASINIT_PRINT_STR,
SCARD_STXT TYPE STRING,
STRAT_LTXT TYPE STRING,
PERS_LTXT TYPE STRING,
OBJ_LTXT TYPE STRING,
MEASINIT TYPE STRING,
MEASINIT_LTXT TYPE STRING,
OWNER TYPE STRING,
STATUS TYPE STRING,
COL01 TYPE STRING,
COL02 TYPE STRING,
COL03 TYPE STRING,
COL04 TYPE STRING,
COL05 TYPE STRING,
COL06 TYPE STRING,
COL07 TYPE STRING,
COL08 TYPE STRING,
COL09 TYPE STRING,
COL10 TYPE STRING,
COL11 TYPE STRING,
COL12 TYPE STRING,
COL13 TYPE STRING,
COL14 TYPE STRING,
COL15 TYPE STRING,
COL16 TYPE STRING,
COL17 TYPE STRING,
COL18 TYPE STRING,
COL19 TYPE STRING,
COL20 TYPE STRING,
COL21 TYPE STRING,
COL22 TYPE STRING,
COL23 TYPE STRING,
COL24 TYPE STRING,
COL25 TYPE STRING,END OF T_EKKO_STR. DATA: WA_UMB_YS_MEASINIT_PRINT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_UMB_YS_MEASINIT_PRINT_STR-SCARD_STXT sy-vline
WA_UMB_YS_MEASINIT_PRINT_STR-STRAT_LTXT sy-vline
WA_UMB_YS_MEASINIT_PRINT_STR-PERS_LTXT sy-vline
WA_UMB_YS_MEASINIT_PRINT_STR-OBJ_LTXT sy-vline
WA_UMB_YS_MEASINIT_PRINT_STR-MEASINIT sy-vline
WA_UMB_YS_MEASINIT_PRINT_STR-MEASINIT_LTXT sy-vline
WA_UMB_YS_MEASINIT_PRINT_STR-OWNER sy-vline
WA_UMB_YS_MEASINIT_PRINT_STR-STATUS sy-vline
WA_UMB_YS_MEASINIT_PRINT_STR-COL01 sy-vline
WA_UMB_YS_MEASINIT_PRINT_STR-COL02 sy-vline
WA_UMB_YS_MEASINIT_PRINT_STR-COL03 sy-vline
WA_UMB_YS_MEASINIT_PRINT_STR-COL04 sy-vline
WA_UMB_YS_MEASINIT_PRINT_STR-COL05 sy-vline
WA_UMB_YS_MEASINIT_PRINT_STR-COL06 sy-vline
WA_UMB_YS_MEASINIT_PRINT_STR-COL07 sy-vline
WA_UMB_YS_MEASINIT_PRINT_STR-COL08 sy-vline
WA_UMB_YS_MEASINIT_PRINT_STR-COL09 sy-vline
WA_UMB_YS_MEASINIT_PRINT_STR-COL10 sy-vline
WA_UMB_YS_MEASINIT_PRINT_STR-COL11 sy-vline
WA_UMB_YS_MEASINIT_PRINT_STR-COL12 sy-vline
WA_UMB_YS_MEASINIT_PRINT_STR-COL13 sy-vline
WA_UMB_YS_MEASINIT_PRINT_STR-COL14 sy-vline
WA_UMB_YS_MEASINIT_PRINT_STR-COL15 sy-vline
WA_UMB_YS_MEASINIT_PRINT_STR-COL16 sy-vline
WA_UMB_YS_MEASINIT_PRINT_STR-COL17 sy-vline
WA_UMB_YS_MEASINIT_PRINT_STR-COL18 sy-vline
WA_UMB_YS_MEASINIT_PRINT_STR-COL19 sy-vline
WA_UMB_YS_MEASINIT_PRINT_STR-COL20 sy-vline
WA_UMB_YS_MEASINIT_PRINT_STR-COL21 sy-vline
WA_UMB_YS_MEASINIT_PRINT_STR-COL22 sy-vline
WA_UMB_YS_MEASINIT_PRINT_STR-COL23 sy-vline
WA_UMB_YS_MEASINIT_PRINT_STR-COL24 sy-vline
WA_UMB_YS_MEASINIT_PRINT_STR-COL25 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.