ABAP Select data from SAP table UMB_YS_INITIATIVE into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP UMB_YS_INITIATIVE table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to UMB_YS_INITIATIVE. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the UMB_YS_INITIATIVE table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_UMB_YS_INITIATIVE TYPE STANDARD TABLE OF UMB_YS_INITIATIVE,
      WA_UMB_YS_INITIATIVE TYPE UMB_YS_INITIATIVE,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <UMB_YS_INITIATIVE> TYPE UMB_YS_INITIATIVE.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_UMB_YS_INITIATIVE.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM UMB_YS_INITIATIVE
  INTO TABLE IT_UMB_YS_INITIATIVE.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM UMB_YS_INITIATIVE
*  INTO TABLE @DATA(IT_UMB_YS_INITIATIVE2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_UMB_YS_INITIATIVE INDEX 1 INTO DATA(WA_UMB_YS_INITIATIVE2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_UMB_YS_INITIATIVE ASSIGNING <UMB_YS_INITIATIVE>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<UMB_YS_INITIATIVE>-MANDT = 1.
<UMB_YS_INITIATIVE>-SCARD = 1.
<UMB_YS_INITIATIVE>-INIT = 1.
<UMB_YS_INITIATIVE>-DURFR = 1.
<UMB_YS_INITIATIVE>-DURTO = 1.
ENDLOOP.

LOOP AT IT_UMB_YS_INITIATIVE INTO WA_UMB_YS_INITIATIVE.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_UMB_YS_INITIATIVE-PRIO, sy-vline,
WA_UMB_YS_INITIATIVE-OWNER, sy-vline,
WA_UMB_YS_INITIATIVE-RFCDEST_BIC, sy-vline,
WA_UMB_YS_INITIATIVE-DOC_ID, sy-vline,
WA_UMB_YS_INITIATIVE-RFCDEST, sy-vline,
WA_UMB_YS_INITIATIVE-ICUBE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_UMB_YS_INITIATIVE you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_UMB_YS_INITIATIVE TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_UMB_YS_INITIATIVE INTO WA_UMB_YS_INITIATIVE. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit PERI7, internal->external for field DURFR CALL FUNCTION 'CONVERSION_EXIT_PERI7_OUTPUT' EXPORTING input = WA_UMB_YS_INITIATIVE-DURFR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_UMB_YS_INITIATIVE-DURFR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit PERI7, internal->external for field DURTO CALL FUNCTION 'CONVERSION_EXIT_PERI7_OUTPUT' EXPORTING input = WA_UMB_YS_INITIATIVE-DURTO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_UMB_YS_INITIATIVE-DURTO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ABPSN, internal->external for field PROJECT CALL FUNCTION 'CONVERSION_EXIT_ABPSN_OUTPUT' EXPORTING input = WA_UMB_YS_INITIATIVE-PROJECT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_UMB_YS_INITIATIVE-PROJECT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ABPSN, internal->external for field WBS_ELEMENT CALL FUNCTION 'CONVERSION_EXIT_ABPSN_OUTPUT' EXPORTING input = WA_UMB_YS_INITIATIVE-WBS_ELEMENT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_UMB_YS_INITIATIVE-WBS_ELEMENT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_UMB_YS_INITIATIVE_STR,
MANDT TYPE STRING,
SCARD TYPE STRING,
INIT TYPE STRING,
DURFR TYPE STRING,
DURTO TYPE STRING,
PRIO TYPE STRING,
OWNER TYPE STRING,
RFCDEST_BIC TYPE STRING,
DOC_ID TYPE STRING,
RFCDEST TYPE STRING,
ICUBE TYPE STRING,
TCUBE TYPE STRING,
IQUERY TYPE STRING,
TQUERY TYPE STRING,
TSTPNM TYPE STRING,
TIMESTMP TYPE STRING,
NOAC TYPE STRING,
ISEQ TYPE STRING,
OWNTYPE TYPE STRING,
VAR TYPE STRING,
PLVAR TYPE STRING,
OTYPE TYPE STRING,
OBJID TYPE STRING,
STATGEN TYPE STRING,
MAP TYPE STRING,
FORMULA TYPE STRING,
CINIT TYPE STRING,
PROJECT TYPE STRING,
WBS_ELEMENT TYPE STRING,
PERIODICITY TYPE STRING,
LTXT TYPE STRING,
MTXT TYPE STRING,
STXT TYPE STRING,
CINITTXT TYPE STRING,
DATASOURCE_FLAG TYPE STRING,END OF T_EKKO_STR. DATA: WA_UMB_YS_INITIATIVE_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_UMB_YS_INITIATIVE_STR-MANDT sy-vline
WA_UMB_YS_INITIATIVE_STR-SCARD sy-vline
WA_UMB_YS_INITIATIVE_STR-INIT sy-vline
WA_UMB_YS_INITIATIVE_STR-DURFR sy-vline
WA_UMB_YS_INITIATIVE_STR-DURTO sy-vline
WA_UMB_YS_INITIATIVE_STR-PRIO sy-vline
WA_UMB_YS_INITIATIVE_STR-OWNER sy-vline
WA_UMB_YS_INITIATIVE_STR-RFCDEST_BIC sy-vline
WA_UMB_YS_INITIATIVE_STR-DOC_ID sy-vline
WA_UMB_YS_INITIATIVE_STR-RFCDEST sy-vline
WA_UMB_YS_INITIATIVE_STR-ICUBE sy-vline
WA_UMB_YS_INITIATIVE_STR-TCUBE sy-vline
WA_UMB_YS_INITIATIVE_STR-IQUERY sy-vline
WA_UMB_YS_INITIATIVE_STR-TQUERY sy-vline
WA_UMB_YS_INITIATIVE_STR-TSTPNM sy-vline
WA_UMB_YS_INITIATIVE_STR-TIMESTMP sy-vline
WA_UMB_YS_INITIATIVE_STR-NOAC sy-vline
WA_UMB_YS_INITIATIVE_STR-ISEQ sy-vline
WA_UMB_YS_INITIATIVE_STR-OWNTYPE sy-vline
WA_UMB_YS_INITIATIVE_STR-VAR sy-vline
WA_UMB_YS_INITIATIVE_STR-PLVAR sy-vline
WA_UMB_YS_INITIATIVE_STR-OTYPE sy-vline
WA_UMB_YS_INITIATIVE_STR-OBJID sy-vline
WA_UMB_YS_INITIATIVE_STR-STATGEN sy-vline
WA_UMB_YS_INITIATIVE_STR-MAP sy-vline
WA_UMB_YS_INITIATIVE_STR-FORMULA sy-vline
WA_UMB_YS_INITIATIVE_STR-CINIT sy-vline
WA_UMB_YS_INITIATIVE_STR-PROJECT sy-vline
WA_UMB_YS_INITIATIVE_STR-WBS_ELEMENT sy-vline
WA_UMB_YS_INITIATIVE_STR-PERIODICITY sy-vline
WA_UMB_YS_INITIATIVE_STR-LTXT sy-vline
WA_UMB_YS_INITIATIVE_STR-MTXT sy-vline
WA_UMB_YS_INITIATIVE_STR-STXT sy-vline
WA_UMB_YS_INITIATIVE_STR-CINITTXT sy-vline
WA_UMB_YS_INITIATIVE_STR-DATASOURCE_FLAG sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.