ABAP Select data from SAP table UKM_S_BP_DYNPRO_FIELDS into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP UKM_S_BP_DYNPRO_FIELDS table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to UKM_S_BP_DYNPRO_FIELDS. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the UKM_S_BP_DYNPRO_FIELDS table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_UKM_S_BP_DYNPRO_FIELDS TYPE STANDARD TABLE OF UKM_S_BP_DYNPRO_FIELDS,
      WA_UKM_S_BP_DYNPRO_FIELDS TYPE UKM_S_BP_DYNPRO_FIELDS,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <UKM_S_BP_DYNPRO_FIELDS> TYPE UKM_S_BP_DYNPRO_FIELDS.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_UKM_S_BP_DYNPRO_FIELDS.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM UKM_S_BP_DYNPRO_FIELDS
  INTO TABLE IT_UKM_S_BP_DYNPRO_FIELDS.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM UKM_S_BP_DYNPRO_FIELDS
*  INTO TABLE @DATA(IT_UKM_S_BP_DYNPRO_FIELDS2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_UKM_S_BP_DYNPRO_FIELDS INDEX 1 INTO DATA(WA_UKM_S_BP_DYNPRO_FIELDS2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_UKM_S_BP_DYNPRO_FIELDS ASSIGNING <UKM_S_BP_DYNPRO_FIELDS>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<UKM_S_BP_DYNPRO_FIELDS>-X_DETAIL = 1.
<UKM_S_BP_DYNPRO_FIELDS>-DUNN_DOC = 1.
<UKM_S_BP_DYNPRO_FIELDS>-PAYMNT_DOC = 1.
<UKM_S_BP_DYNPRO_FIELDS>-OVDUE_DOC = 1.
<UKM_S_BP_DYNPRO_FIELDS>-SEGMENT = 1.
ENDLOOP.

LOOP AT IT_UKM_S_BP_DYNPRO_FIELDS INTO WA_UKM_S_BP_DYNPRO_FIELDS.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_UKM_S_BP_DYNPRO_FIELDS-X_DELETE, sy-vline,
WA_UKM_S_BP_DYNPRO_FIELDS-X_IMPORT_BP1012, sy-vline,
WA_UKM_S_BP_DYNPRO_FIELDS-X_RISK_EDIT, sy-vline,
WA_UKM_S_BP_DYNPRO_FIELDS-PUSH_COLLAPSE, sy-vline,
WA_UKM_S_BP_DYNPRO_FIELDS-PUSH_EXPAND, sy-vline,
WA_UKM_S_BP_DYNPRO_FIELDS-RISK_CLASS_CALC, sy-vline.
ENDLOOP. *Add any further fields from structure WA_UKM_S_BP_DYNPRO_FIELDS you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_UKM_S_BP_DYNPRO_FIELDS TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_UKM_S_BP_DYNPRO_FIELDS INTO WA_UKM_S_BP_DYNPRO_FIELDS. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_UKM_S_BP_DYNPRO_FIELDS_STR,
X_DETAIL TYPE STRING,
DUNN_DOC TYPE STRING,
PAYMNT_DOC TYPE STRING,
OVDUE_DOC TYPE STRING,
SEGMENT TYPE STRING,
X_DELETE TYPE STRING,
X_IMPORT_BP1012 TYPE STRING,
X_RISK_EDIT TYPE STRING,
PUSH_COLLAPSE TYPE STRING,
PUSH_EXPAND TYPE STRING,
RISK_CLASS_CALC TYPE STRING,
LIMIT_RULE TYPE STRING,
FORMULA_TXT TYPE STRING,
GRADE_DATE TYPE STRING,
X_LIMIT_NOT_SET TYPE STRING,
X_LIMIT_IS_SET TYPE STRING,
X_APPROVE_LIMIT TYPE STRING,
X_REJECT_LIMIT TYPE STRING,
IDX_FIGURE TYPE STRING,
CREDIT_CHECK_SIMU TYPE STRING,
DCD_CMA_EXIST TYPE STRING,
DCD_CMA_CASE_GUID TYPE STRING,END OF T_EKKO_STR. DATA: WA_UKM_S_BP_DYNPRO_FIELDS_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_UKM_S_BP_DYNPRO_FIELDS_STR-X_DETAIL sy-vline
WA_UKM_S_BP_DYNPRO_FIELDS_STR-DUNN_DOC sy-vline
WA_UKM_S_BP_DYNPRO_FIELDS_STR-PAYMNT_DOC sy-vline
WA_UKM_S_BP_DYNPRO_FIELDS_STR-OVDUE_DOC sy-vline
WA_UKM_S_BP_DYNPRO_FIELDS_STR-SEGMENT sy-vline
WA_UKM_S_BP_DYNPRO_FIELDS_STR-X_DELETE sy-vline
WA_UKM_S_BP_DYNPRO_FIELDS_STR-X_IMPORT_BP1012 sy-vline
WA_UKM_S_BP_DYNPRO_FIELDS_STR-X_RISK_EDIT sy-vline
WA_UKM_S_BP_DYNPRO_FIELDS_STR-PUSH_COLLAPSE sy-vline
WA_UKM_S_BP_DYNPRO_FIELDS_STR-PUSH_EXPAND sy-vline
WA_UKM_S_BP_DYNPRO_FIELDS_STR-RISK_CLASS_CALC sy-vline
WA_UKM_S_BP_DYNPRO_FIELDS_STR-LIMIT_RULE sy-vline
WA_UKM_S_BP_DYNPRO_FIELDS_STR-FORMULA_TXT sy-vline
WA_UKM_S_BP_DYNPRO_FIELDS_STR-GRADE_DATE sy-vline
WA_UKM_S_BP_DYNPRO_FIELDS_STR-X_LIMIT_NOT_SET sy-vline
WA_UKM_S_BP_DYNPRO_FIELDS_STR-X_LIMIT_IS_SET sy-vline
WA_UKM_S_BP_DYNPRO_FIELDS_STR-X_APPROVE_LIMIT sy-vline
WA_UKM_S_BP_DYNPRO_FIELDS_STR-X_REJECT_LIMIT sy-vline
WA_UKM_S_BP_DYNPRO_FIELDS_STR-IDX_FIGURE sy-vline
WA_UKM_S_BP_DYNPRO_FIELDS_STR-CREDIT_CHECK_SIMU sy-vline
WA_UKM_S_BP_DYNPRO_FIELDS_STR-DCD_CMA_EXIST sy-vline
WA_UKM_S_BP_DYNPRO_FIELDS_STR-DCD_CMA_CASE_GUID sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.