ABAP Select data from SAP table UISS_S_IS_PP_INTORDER into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP UISS_S_IS_PP_INTORDER table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to UISS_S_IS_PP_INTORDER. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the UISS_S_IS_PP_INTORDER table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_UISS_S_IS_PP_INTORDER TYPE STANDARD TABLE OF UISS_S_IS_PP_INTORDER,
      WA_UISS_S_IS_PP_INTORDER TYPE UISS_S_IS_PP_INTORDER,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <UISS_S_IS_PP_INTORDER> TYPE UISS_S_IS_PP_INTORDER.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_UISS_S_IS_PP_INTORDER.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM UISS_S_IS_PP_INTORDER
  INTO TABLE IT_UISS_S_IS_PP_INTORDER.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM UISS_S_IS_PP_INTORDER
*  INTO TABLE @DATA(IT_UISS_S_IS_PP_INTORDER2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_UISS_S_IS_PP_INTORDER INDEX 1 INTO DATA(WA_UISS_S_IS_PP_INTORDER2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_UISS_S_IS_PP_INTORDER ASSIGNING <UISS_S_IS_PP_INTORDER>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<UISS_S_IS_PP_INTORDER>-COAREA = 1.
<UISS_S_IS_PP_INTORDER>-ORDERTYPE = 1.
<UISS_S_IS_PP_INTORDER>-SYSTEM = 1.
<UISS_S_IS_PP_INTORDER>-INTORDER = 1.
<UISS_S_IS_PP_INTORDER>-AIOBUSAR = 1.
ENDLOOP.

LOOP AT IT_UISS_S_IS_PP_INTORDER INTO WA_UISS_S_IS_PP_INTORDER.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_UISS_S_IS_PP_INTORDER-AIOCHUSR, sy-vline,
WA_UISS_S_IS_PP_INTORDER-AIOITPCT, sy-vline,
WA_UISS_S_IS_PP_INTORDER-AIOKALSM, sy-vline,
WA_UISS_S_IS_PP_INTORDER-AIOOHKEY, sy-vline,
WA_UISS_S_IS_PP_INTORDER-AIOPLANT, sy-vline,
WA_UISS_S_IS_PP_INTORDER-AIORAKEY, sy-vline.
ENDLOOP. *Add any further fields from structure WA_UISS_S_IS_PP_INTORDER you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_UISS_S_IS_PP_INTORDER TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_UISS_S_IS_PP_INTORDER INTO WA_UISS_S_IS_PP_INTORDER. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field SYSTEM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_UISS_S_IS_PP_INTORDER-SYSTEM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_UISS_S_IS_PP_INTORDER-SYSTEM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field INTORDER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_UISS_S_IS_PP_INTORDER-INTORDER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_UISS_S_IS_PP_INTORDER-INTORDER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field EXTORDNUM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_UISS_S_IS_PP_INTORDER-EXTORDNUM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_UISS_S_IS_PP_INTORDER-EXTORDNUM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PCTRORDER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_UISS_S_IS_PP_INTORDER-PCTRORDER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_UISS_S_IS_PP_INTORDER-PCTRORDER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field REQCCTR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_UISS_S_IS_PP_INTORDER-REQCCTR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_UISS_S_IS_PP_INTORDER-REQCCTR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RESPCCTR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_UISS_S_IS_PP_INTORDER-RESPCCTR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_UISS_S_IS_PP_INTORDER-RESPCCTR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SETCELEM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_UISS_S_IS_PP_INTORDER-SETCELEM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_UISS_S_IS_PP_INTORDER-SETCELEM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SETLORDER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_UISS_S_IS_PP_INTORDER-SETLORDER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_UISS_S_IS_PP_INTORDER-SETLORDER.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_UISS_S_IS_PP_INTORDER_STR,
COAREA TYPE STRING,
ORDERTYPE TYPE STRING,
SYSTEM TYPE STRING,
INTORDER TYPE STRING,
AIOBUSAR TYPE STRING,
AIOCHUSR TYPE STRING,
AIOITPCT TYPE STRING,
AIOKALSM TYPE STRING,
AIOOHKEY TYPE STRING,
AIOPLANT TYPE STRING,
AIORAKEY TYPE STRING,
AIOSALOD TYPE STRING,
AIOTAXJR TYPE STRING,
APPDATE TYPE STRING,
APPLICANT TYPE STRING,
APPPHONE TYPE STRING,
COMPORDER TYPE STRING,
DEPMENT TYPE STRING,
ESTCOST TYPE STRING,
EXTORDNUM TYPE STRING,
FAINTORER TYPE STRING,
FDATEIO TYPE STRING,
OBJCLASS TYPE STRING,
OBJECTNUM TYPE STRING,
ORDERNAME TYPE STRING,
PCTRORDER TYPE STRING,
PLNCLOSE TYPE STRING,
PLNCOMPL TYPE STRING,
PLNRELEAS TYPE STRING,
REQCCTR TYPE STRING,
RESPCCTR TYPE STRING,
SETCELEM TYPE STRING,
SETLORDER TYPE STRING,
SORDITEM TYPE STRING,
TDATEINTO TYPE STRING,
TXTSH TYPE STRING,
USER TYPE STRING,
USERPHONE TYPE STRING,
WORKBEGDA TYPE STRING,
WORKENDDA TYPE STRING,
WORKPERMI TYPE STRING,END OF T_EKKO_STR. DATA: WA_UISS_S_IS_PP_INTORDER_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_UISS_S_IS_PP_INTORDER_STR-COAREA sy-vline
WA_UISS_S_IS_PP_INTORDER_STR-ORDERTYPE sy-vline
WA_UISS_S_IS_PP_INTORDER_STR-SYSTEM sy-vline
WA_UISS_S_IS_PP_INTORDER_STR-INTORDER sy-vline
WA_UISS_S_IS_PP_INTORDER_STR-AIOBUSAR sy-vline
WA_UISS_S_IS_PP_INTORDER_STR-AIOCHUSR sy-vline
WA_UISS_S_IS_PP_INTORDER_STR-AIOITPCT sy-vline
WA_UISS_S_IS_PP_INTORDER_STR-AIOKALSM sy-vline
WA_UISS_S_IS_PP_INTORDER_STR-AIOOHKEY sy-vline
WA_UISS_S_IS_PP_INTORDER_STR-AIOPLANT sy-vline
WA_UISS_S_IS_PP_INTORDER_STR-AIORAKEY sy-vline
WA_UISS_S_IS_PP_INTORDER_STR-AIOSALOD sy-vline
WA_UISS_S_IS_PP_INTORDER_STR-AIOTAXJR sy-vline
WA_UISS_S_IS_PP_INTORDER_STR-APPDATE sy-vline
WA_UISS_S_IS_PP_INTORDER_STR-APPLICANT sy-vline
WA_UISS_S_IS_PP_INTORDER_STR-APPPHONE sy-vline
WA_UISS_S_IS_PP_INTORDER_STR-COMPORDER sy-vline
WA_UISS_S_IS_PP_INTORDER_STR-DEPMENT sy-vline
WA_UISS_S_IS_PP_INTORDER_STR-ESTCOST sy-vline
WA_UISS_S_IS_PP_INTORDER_STR-EXTORDNUM sy-vline
WA_UISS_S_IS_PP_INTORDER_STR-FAINTORER sy-vline
WA_UISS_S_IS_PP_INTORDER_STR-FDATEIO sy-vline
WA_UISS_S_IS_PP_INTORDER_STR-OBJCLASS sy-vline
WA_UISS_S_IS_PP_INTORDER_STR-OBJECTNUM sy-vline
WA_UISS_S_IS_PP_INTORDER_STR-ORDERNAME sy-vline
WA_UISS_S_IS_PP_INTORDER_STR-PCTRORDER sy-vline
WA_UISS_S_IS_PP_INTORDER_STR-PLNCLOSE sy-vline
WA_UISS_S_IS_PP_INTORDER_STR-PLNCOMPL sy-vline
WA_UISS_S_IS_PP_INTORDER_STR-PLNRELEAS sy-vline
WA_UISS_S_IS_PP_INTORDER_STR-REQCCTR sy-vline
WA_UISS_S_IS_PP_INTORDER_STR-RESPCCTR sy-vline
WA_UISS_S_IS_PP_INTORDER_STR-SETCELEM sy-vline
WA_UISS_S_IS_PP_INTORDER_STR-SETLORDER sy-vline
WA_UISS_S_IS_PP_INTORDER_STR-SORDITEM sy-vline
WA_UISS_S_IS_PP_INTORDER_STR-TDATEINTO sy-vline
WA_UISS_S_IS_PP_INTORDER_STR-TXTSH sy-vline
WA_UISS_S_IS_PP_INTORDER_STR-USER sy-vline
WA_UISS_S_IS_PP_INTORDER_STR-USERPHONE sy-vline
WA_UISS_S_IS_PP_INTORDER_STR-WORKBEGDA sy-vline
WA_UISS_S_IS_PP_INTORDER_STR-WORKENDDA sy-vline
WA_UISS_S_IS_PP_INTORDER_STR-WORKPERMI sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.