ABAP Select data from SAP table UISS_S_IS_PP_CCTR into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP UISS_S_IS_PP_CCTR table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to UISS_S_IS_PP_CCTR. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the UISS_S_IS_PP_CCTR table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_UISS_S_IS_PP_CCTR TYPE STANDARD TABLE OF UISS_S_IS_PP_CCTR,
      WA_UISS_S_IS_PP_CCTR TYPE UISS_S_IS_PP_CCTR,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <UISS_S_IS_PP_CCTR> TYPE UISS_S_IS_PP_CCTR.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_UISS_S_IS_PP_CCTR.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM UISS_S_IS_PP_CCTR
  INTO TABLE IT_UISS_S_IS_PP_CCTR.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM UISS_S_IS_PP_CCTR
*  INTO TABLE @DATA(IT_UISS_S_IS_PP_CCTR2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_UISS_S_IS_PP_CCTR INDEX 1 INTO DATA(WA_UISS_S_IS_PP_CCTR2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_UISS_S_IS_PP_CCTR ASSIGNING <UISS_S_IS_PP_CCTR>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<UISS_S_IS_PP_CCTR>-COAREA = 1.
<UISS_S_IS_PP_CCTR>-SYSTEM = 1.
<UISS_S_IS_PP_CCTR>-CCTR = 1.
<UISS_S_IS_PP_CCTR>-TXTSH = 1.
<UISS_S_IS_PP_CCTR>-TXTMI = 1.
ENDLOOP.

LOOP AT IT_UISS_S_IS_PP_CCTR INTO WA_UISS_S_IS_PP_CCTR.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_UISS_S_IS_PP_CCTR-LANGU, sy-vline,
WA_UISS_S_IS_PP_CCTR-FDATECCTR, sy-vline,
WA_UISS_S_IS_PP_CCTR-TDATECCTR, sy-vline,
WA_UISS_S_IS_PP_CCTR-CCTRSTDH, sy-vline,
WA_UISS_S_IS_PP_CCTR-CCTRLKAPP, sy-vline,
WA_UISS_S_IS_PP_CCTR-CCTRLKPPC, sy-vline.
ENDLOOP. *Add any further fields from structure WA_UISS_S_IS_PP_CCTR you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_UISS_S_IS_PP_CCTR TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_UISS_S_IS_PP_CCTR INTO WA_UISS_S_IS_PP_CCTR. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field SYSTEM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_UISS_S_IS_PP_CCTR-SYSTEM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_UISS_S_IS_PP_CCTR-SYSTEM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ISOLA, internal->external for field LANGU CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_UISS_S_IS_PP_CCTR-LANGU IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_UISS_S_IS_PP_CCTR-LANGU.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field CCTRLSYS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_UISS_S_IS_PP_CCTR-CCTRLSYS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_UISS_S_IS_PP_CCTR-CCTRLSYS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PCTRCCTR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_UISS_S_IS_PP_CCTR-PCTRCCTR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_UISS_S_IS_PP_CCTR-PCTRCCTR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_UISS_S_IS_PP_CCTR_STR,
COAREA TYPE STRING,
SYSTEM TYPE STRING,
CCTR TYPE STRING,
TXTSH TYPE STRING,
TXTMI TYPE STRING,
LANGU TYPE STRING,
FDATECCTR TYPE STRING,
TDATECCTR TYPE STRING,
CCTRSTDH TYPE STRING,
CCTRLKAPP TYPE STRING,
CCTRLKPPC TYPE STRING,
CCTRLKASC TYPE STRING,
CCTRLKPSC TYPE STRING,
CCTRLKARP TYPE STRING,
CCTRLKPRV TYPE STRING,
CCTRLKCUP TYPE STRING,
ACCTRCGY TYPE STRING,
ACCTRRPU TYPE STRING,
ACCTRRTX TYPE STRING,
ACCTRBAR TYPE STRING,
CCTRRESPP TYPE STRING,
CCTRLSYS TYPE STRING,
CCODECCTR TYPE STRING,
CCTRCCTRN TYPE STRING,
CCTRDEPT TYPE STRING,
CCTRQTYRQ TYPE STRING,
CURRCCTR TYPE STRING,
FUNCCCTR TYPE STRING,
PCTRCCTR TYPE STRING,
CCTRNAME TYPE STRING,END OF T_EKKO_STR. DATA: WA_UISS_S_IS_PP_CCTR_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_UISS_S_IS_PP_CCTR_STR-COAREA sy-vline
WA_UISS_S_IS_PP_CCTR_STR-SYSTEM sy-vline
WA_UISS_S_IS_PP_CCTR_STR-CCTR sy-vline
WA_UISS_S_IS_PP_CCTR_STR-TXTSH sy-vline
WA_UISS_S_IS_PP_CCTR_STR-TXTMI sy-vline
WA_UISS_S_IS_PP_CCTR_STR-LANGU sy-vline
WA_UISS_S_IS_PP_CCTR_STR-FDATECCTR sy-vline
WA_UISS_S_IS_PP_CCTR_STR-TDATECCTR sy-vline
WA_UISS_S_IS_PP_CCTR_STR-CCTRSTDH sy-vline
WA_UISS_S_IS_PP_CCTR_STR-CCTRLKAPP sy-vline
WA_UISS_S_IS_PP_CCTR_STR-CCTRLKPPC sy-vline
WA_UISS_S_IS_PP_CCTR_STR-CCTRLKASC sy-vline
WA_UISS_S_IS_PP_CCTR_STR-CCTRLKPSC sy-vline
WA_UISS_S_IS_PP_CCTR_STR-CCTRLKARP sy-vline
WA_UISS_S_IS_PP_CCTR_STR-CCTRLKPRV sy-vline
WA_UISS_S_IS_PP_CCTR_STR-CCTRLKCUP sy-vline
WA_UISS_S_IS_PP_CCTR_STR-ACCTRCGY sy-vline
WA_UISS_S_IS_PP_CCTR_STR-ACCTRRPU sy-vline
WA_UISS_S_IS_PP_CCTR_STR-ACCTRRTX sy-vline
WA_UISS_S_IS_PP_CCTR_STR-ACCTRBAR sy-vline
WA_UISS_S_IS_PP_CCTR_STR-CCTRRESPP sy-vline
WA_UISS_S_IS_PP_CCTR_STR-CCTRLSYS sy-vline
WA_UISS_S_IS_PP_CCTR_STR-CCODECCTR sy-vline
WA_UISS_S_IS_PP_CCTR_STR-CCTRCCTRN sy-vline
WA_UISS_S_IS_PP_CCTR_STR-CCTRDEPT sy-vline
WA_UISS_S_IS_PP_CCTR_STR-CCTRQTYRQ sy-vline
WA_UISS_S_IS_PP_CCTR_STR-CURRCCTR sy-vline
WA_UISS_S_IS_PP_CCTR_STR-FUNCCCTR sy-vline
WA_UISS_S_IS_PP_CCTR_STR-PCTRCCTR sy-vline
WA_UISS_S_IS_PP_CCTR_STR-CCTRNAME sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.