ABAP Select data from SAP table UISS_CELEM_DATA into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP UISS_CELEM_DATA table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to UISS_CELEM_DATA. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the UISS_CELEM_DATA table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_UISS_CELEM_DATA TYPE STANDARD TABLE OF UISS_CELEM_DATA,
      WA_UISS_CELEM_DATA TYPE UISS_CELEM_DATA,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <UISS_CELEM_DATA> TYPE UISS_CELEM_DATA.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_UISS_CELEM_DATA.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM UISS_CELEM_DATA
  INTO TABLE IT_UISS_CELEM_DATA.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM UISS_CELEM_DATA
*  INTO TABLE @DATA(IT_UISS_CELEM_DATA2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_UISS_CELEM_DATA INDEX 1 INTO DATA(WA_UISS_CELEM_DATA2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_UISS_CELEM_DATA ASSIGNING <UISS_CELEM_DATA>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<UISS_CELEM_DATA>-SYSTEM = 1.
<UISS_CELEM_DATA>-CELEM = 1.
<UISS_CELEM_DATA>-COAREA = 1.
<UISS_CELEM_DATA>-ACELECAT = 1.
<UISS_CELEM_DATA>-CELEMINDQ = 1.
ENDLOOP.

LOOP AT IT_UISS_CELEM_DATA INTO WA_UISS_CELEM_DATA.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_UISS_CELEM_DATA-CCTRCELEM, sy-vline,
WA_UISS_CELEM_DATA-TDATECELE, sy-vline,
WA_UISS_CELEM_DATA-FDATECELE, sy-vline,
WA_UISS_CELEM_DATA-CELEM_CLASS, sy-vline,
WA_UISS_CELEM_DATA-ACELEORD, sy-vline,
WA_UISS_CELEM_DATA-FUNCCELEM, sy-vline.
ENDLOOP. *Add any further fields from structure WA_UISS_CELEM_DATA you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_UISS_CELEM_DATA TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_UISS_CELEM_DATA INTO WA_UISS_CELEM_DATA. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field SYSTEM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_UISS_CELEM_DATA-SYSTEM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_UISS_CELEM_DATA-SYSTEM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field CELEM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_UISS_CELEM_DATA-CELEM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_UISS_CELEM_DATA-CELEM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ACELECAT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_UISS_CELEM_DATA-ACELECAT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_UISS_CELEM_DATA-ACELECAT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field CCTRCELEM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_UISS_CELEM_DATA-CCTRCELEM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_UISS_CELEM_DATA-CCTRCELEM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ACELEORD CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_UISS_CELEM_DATA-ACELEORD IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_UISS_CELEM_DATA-ACELEORD.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UOMCELEM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_UISS_CELEM_DATA-UOMCELEM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_UISS_CELEM_DATA-UOMCELEM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RECIND CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_UISS_CELEM_DATA-RECIND IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_UISS_CELEM_DATA-RECIND.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ISOLA, internal->external for field LANGU CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_UISS_CELEM_DATA-LANGU IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_UISS_CELEM_DATA-LANGU.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_UISS_CELEM_DATA_STR,
SYSTEM TYPE STRING,
CELEM TYPE STRING,
COAREA TYPE STRING,
ACELECAT TYPE STRING,
CELEMINDQ TYPE STRING,
CCTRCELEM TYPE STRING,
TDATECELE TYPE STRING,
FDATECELE TYPE STRING,
CELEM_CLASS TYPE STRING,
ACELEORD TYPE STRING,
FUNCCELEM TYPE STRING,
UOMCELEM TYPE STRING,
TXTSH TYPE STRING,
TXTMI TYPE STRING,
RECIND TYPE STRING,
LANGU TYPE STRING,
CELEMNAME TYPE STRING,END OF T_EKKO_STR. DATA: WA_UISS_CELEM_DATA_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_UISS_CELEM_DATA_STR-SYSTEM sy-vline
WA_UISS_CELEM_DATA_STR-CELEM sy-vline
WA_UISS_CELEM_DATA_STR-COAREA sy-vline
WA_UISS_CELEM_DATA_STR-ACELECAT sy-vline
WA_UISS_CELEM_DATA_STR-CELEMINDQ sy-vline
WA_UISS_CELEM_DATA_STR-CCTRCELEM sy-vline
WA_UISS_CELEM_DATA_STR-TDATECELE sy-vline
WA_UISS_CELEM_DATA_STR-FDATECELE sy-vline
WA_UISS_CELEM_DATA_STR-CELEM_CLASS sy-vline
WA_UISS_CELEM_DATA_STR-ACELEORD sy-vline
WA_UISS_CELEM_DATA_STR-FUNCCELEM sy-vline
WA_UISS_CELEM_DATA_STR-UOMCELEM sy-vline
WA_UISS_CELEM_DATA_STR-TXTSH sy-vline
WA_UISS_CELEM_DATA_STR-TXTMI sy-vline
WA_UISS_CELEM_DATA_STR-RECIND sy-vline
WA_UISS_CELEM_DATA_STR-LANGU sy-vline
WA_UISS_CELEM_DATA_STR-CELEMNAME sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.