ABAP Select data from SAP table UHC_FICA_S_CCATTR into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP UHC_FICA_S_CCATTR table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to UHC_FICA_S_CCATTR. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the UHC_FICA_S_CCATTR table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_UHC_FICA_S_CCATTR TYPE STANDARD TABLE OF UHC_FICA_S_CCATTR,
      WA_UHC_FICA_S_CCATTR TYPE UHC_FICA_S_CCATTR,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <UHC_FICA_S_CCATTR> TYPE UHC_FICA_S_CCATTR.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_UHC_FICA_S_CCATTR.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM UHC_FICA_S_CCATTR
  INTO TABLE IT_UHC_FICA_S_CCATTR.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM UHC_FICA_S_CCATTR
*  INTO TABLE @DATA(IT_UHC_FICA_S_CCATTR2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_UHC_FICA_S_CCATTR INDEX 1 INTO DATA(WA_UHC_FICA_S_CCATTR2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_UHC_FICA_S_CCATTR ASSIGNING <UHC_FICA_S_CCATTR>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<UHC_FICA_S_CCATTR>-FICA_GPART = 1.
<UHC_FICA_S_CCATTR>-FCL_GPART_DESCR = 1.
<UHC_FICA_S_CCATTR>-FICA_CONT_GPART = 1.
<UHC_FICA_S_CCATTR>-FCL_C_GP_DESCR = 1.
<UHC_FICA_S_CCATTR>-FICA_VKONT = 1.
ENDLOOP.

LOOP AT IT_UHC_FICA_S_CCATTR INTO WA_UHC_FICA_S_CCATTR.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_UHC_FICA_S_CCATTR-FCL_ITEM_LIST, sy-vline,
WA_UHC_FICA_S_CCATTR-FCL_OPEN_AM, sy-vline,
WA_UHC_FICA_S_CCATTR-FCL_PAID_AGENT, sy-vline,
WA_UHC_FICA_S_CCATTR-FCL_REVERSED, sy-vline,
WA_UHC_FICA_S_CCATTR-FCL_WRITEOFF, sy-vline,
WA_UHC_FICA_S_CCATTR-FCL_CLEARED, sy-vline.
ENDLOOP. *Add any further fields from structure WA_UHC_FICA_S_CCATTR you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_UHC_FICA_S_CCATTR TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_UHC_FICA_S_CCATTR INTO WA_UHC_FICA_S_CCATTR. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field FICA_GPART CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_UHC_FICA_S_CCATTR-FICA_GPART IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_UHC_FICA_S_CCATTR-FICA_GPART.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field FICA_CONT_GPART CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_UHC_FICA_S_CCATTR-FICA_CONT_GPART IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_UHC_FICA_S_CCATTR-FICA_CONT_GPART.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field FICA_VKONT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_UHC_FICA_S_CCATTR-FICA_VKONT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_UHC_FICA_S_CCATTR-FICA_VKONT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field FIN_LOG_SYSTEM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_UHC_FICA_S_CCATTR-FIN_LOG_SYSTEM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_UHC_FICA_S_CCATTR-FIN_LOG_SYSTEM.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_UHC_FICA_S_CCATTR_STR,
FICA_GPART TYPE STRING,
FCL_GPART_DESCR TYPE STRING,
FICA_CONT_GPART TYPE STRING,
FCL_C_GP_DESCR TYPE STRING,
FICA_VKONT TYPE STRING,
FCL_ITEM_LIST TYPE STRING,
FCL_OPEN_AM TYPE STRING,
FCL_PAID_AGENT TYPE STRING,
FCL_REVERSED TYPE STRING,
FCL_WRITEOFF TYPE STRING,
FCL_CLEARED TYPE STRING,
FCL_NOCHANGE TYPE STRING,
FIN_DISPUTE_CURR TYPE STRING,
FIN_RFC_CREATOR TYPE STRING,
FIN_LOG_SYSTEM TYPE STRING,
FIN_BUKRS TYPE STRING,
FIN_DUE_DATE TYPE STRING,
FIN_CONTACT_NAME TYPE STRING,
FIN_CONTACT_MAIL TYPE STRING,
FIN_CONTACT_TEL TYPE STRING,
FIN_CONTACT_FAXC TYPE STRING,
FIN_CONTACT_FAX TYPE STRING,
FICA_CONTACT_KEY TYPE STRING,
FIN_PROC_SEQNR TYPE STRING,
FIN_COORDINATOR TYPE STRING,
FCL_ACLIST TYPE STRING,END OF T_EKKO_STR. DATA: WA_UHC_FICA_S_CCATTR_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_UHC_FICA_S_CCATTR_STR-FICA_GPART sy-vline
WA_UHC_FICA_S_CCATTR_STR-FCL_GPART_DESCR sy-vline
WA_UHC_FICA_S_CCATTR_STR-FICA_CONT_GPART sy-vline
WA_UHC_FICA_S_CCATTR_STR-FCL_C_GP_DESCR sy-vline
WA_UHC_FICA_S_CCATTR_STR-FICA_VKONT sy-vline
WA_UHC_FICA_S_CCATTR_STR-FCL_ITEM_LIST sy-vline
WA_UHC_FICA_S_CCATTR_STR-FCL_OPEN_AM sy-vline
WA_UHC_FICA_S_CCATTR_STR-FCL_PAID_AGENT sy-vline
WA_UHC_FICA_S_CCATTR_STR-FCL_REVERSED sy-vline
WA_UHC_FICA_S_CCATTR_STR-FCL_WRITEOFF sy-vline
WA_UHC_FICA_S_CCATTR_STR-FCL_CLEARED sy-vline
WA_UHC_FICA_S_CCATTR_STR-FCL_NOCHANGE sy-vline
WA_UHC_FICA_S_CCATTR_STR-FIN_DISPUTE_CURR sy-vline
WA_UHC_FICA_S_CCATTR_STR-FIN_RFC_CREATOR sy-vline
WA_UHC_FICA_S_CCATTR_STR-FIN_LOG_SYSTEM sy-vline
WA_UHC_FICA_S_CCATTR_STR-FIN_BUKRS sy-vline
WA_UHC_FICA_S_CCATTR_STR-FIN_DUE_DATE sy-vline
WA_UHC_FICA_S_CCATTR_STR-FIN_CONTACT_NAME sy-vline
WA_UHC_FICA_S_CCATTR_STR-FIN_CONTACT_MAIL sy-vline
WA_UHC_FICA_S_CCATTR_STR-FIN_CONTACT_TEL sy-vline
WA_UHC_FICA_S_CCATTR_STR-FIN_CONTACT_FAXC sy-vline
WA_UHC_FICA_S_CCATTR_STR-FIN_CONTACT_FAX sy-vline
WA_UHC_FICA_S_CCATTR_STR-FICA_CONTACT_KEY sy-vline
WA_UHC_FICA_S_CCATTR_STR-FIN_PROC_SEQNR sy-vline
WA_UHC_FICA_S_CCATTR_STR-FIN_COORDINATOR sy-vline
WA_UHC_FICA_S_CCATTR_STR-FCL_ACLIST sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.