ABAP Select data from SAP table UEKEK into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP UEKEK table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to UEKEK. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the UEKEK table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_UEKEK TYPE STANDARD TABLE OF UEKEK,
      WA_UEKEK TYPE UEKEK,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <UEKEK> TYPE UEKEK.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_UEKEK.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM UEKEK
  INTO TABLE IT_UEKEK.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM UEKEK
*  INTO TABLE @DATA(IT_UEKEK2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_UEKEK INDEX 1 INTO DATA(WA_UEKEK2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_UEKEK ASSIGNING <UEKEK>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<UEKEK>-MANDT = 1.
<UEKEK>-EBELN = 1.
<UEKEK>-EBELP = 1.
<UEKEK>-ABART = 1.
<UEKEK>-ABRUF = 1.
ENDLOOP.

LOOP AT IT_UEKEK INTO WA_UEKEK.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_UEKEK-ABEFZ, sy-vline,
WA_UEKEK-ABRDT, sy-vline,
WA_UEKEK-LFDKD, sy-vline,
WA_UEKEK-LFNKD, sy-vline,
WA_UEKEK-LWEDT, sy-vline,
WA_UEKEK-LWEMG, sy-vline.
ENDLOOP. *Add any further fields from structure WA_UEKEK you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_UEKEK TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_UEKEK INTO WA_UEKEK. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field EBELN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_UEKEK-EBELN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_UEKEK-EBELN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field LOADCARR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_UEKEK-LOADCARR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_UEKEK-LOADCARR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field BASEUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_UEKEK-BASEUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_UEKEK-BASEUNIT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_UEKEK_STR,
MANDT TYPE STRING,
EBELN TYPE STRING,
EBELP TYPE STRING,
ABART TYPE STRING,
ABRUF TYPE STRING,
ABEFZ TYPE STRING,
ABRDT TYPE STRING,
LFDKD TYPE STRING,
LFNKD TYPE STRING,
LWEDT TYPE STRING,
LWEMG TYPE STRING,
ABLLI TYPE STRING,
ERDAT TYPE STRING,
ABSFZ TYPE STRING,
ABFDE TYPE STRING,
ABMDE TYPE STRING,
ERUHR TYPE STRING,
ABRZT TYPE STRING,
ABHZT TYPE STRING,
RUSKZ TYPE STRING,
STAAB TYPE STRING,
WEBRL TYPE STRING,
LOADINGPOINT TYPE STRING,
VENCF TYPE STRING,
CPUDT TYPE STRING,
CPUTM TYPE STRING,
STPIN TYPE STRING,
BRSVZ TYPE STRING,
ERSGR TYPE STRING,
LGBZO TYPE STRING,
INIDT TYPE STRING,
INITM TYPE STRING,
WEFZMIT TYPE STRING,
DISPO TYPE STRING,
LOADCARR TYPE STRING,
T_TRGQTY TYPE STRING,
BASEUNIT TYPE STRING,
LCTXT TYPE STRING,
AKSTOPGR TYPE STRING,
KZ TYPE STRING,
EKKOWAERS TYPE STRING,END OF T_EKKO_STR. DATA: WA_UEKEK_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_UEKEK_STR-MANDT sy-vline
WA_UEKEK_STR-EBELN sy-vline
WA_UEKEK_STR-EBELP sy-vline
WA_UEKEK_STR-ABART sy-vline
WA_UEKEK_STR-ABRUF sy-vline
WA_UEKEK_STR-ABEFZ sy-vline
WA_UEKEK_STR-ABRDT sy-vline
WA_UEKEK_STR-LFDKD sy-vline
WA_UEKEK_STR-LFNKD sy-vline
WA_UEKEK_STR-LWEDT sy-vline
WA_UEKEK_STR-LWEMG sy-vline
WA_UEKEK_STR-ABLLI sy-vline
WA_UEKEK_STR-ERDAT sy-vline
WA_UEKEK_STR-ABSFZ sy-vline
WA_UEKEK_STR-ABFDE sy-vline
WA_UEKEK_STR-ABMDE sy-vline
WA_UEKEK_STR-ERUHR sy-vline
WA_UEKEK_STR-ABRZT sy-vline
WA_UEKEK_STR-ABHZT sy-vline
WA_UEKEK_STR-RUSKZ sy-vline
WA_UEKEK_STR-STAAB sy-vline
WA_UEKEK_STR-WEBRL sy-vline
WA_UEKEK_STR-LOADINGPOINT sy-vline
WA_UEKEK_STR-VENCF sy-vline
WA_UEKEK_STR-CPUDT sy-vline
WA_UEKEK_STR-CPUTM sy-vline
WA_UEKEK_STR-STPIN sy-vline
WA_UEKEK_STR-BRSVZ sy-vline
WA_UEKEK_STR-ERSGR sy-vline
WA_UEKEK_STR-LGBZO sy-vline
WA_UEKEK_STR-INIDT sy-vline
WA_UEKEK_STR-INITM sy-vline
WA_UEKEK_STR-WEFZMIT sy-vline
WA_UEKEK_STR-DISPO sy-vline
WA_UEKEK_STR-LOADCARR sy-vline
WA_UEKEK_STR-T_TRGQTY sy-vline
WA_UEKEK_STR-BASEUNIT sy-vline
WA_UEKEK_STR-LCTXT sy-vline
WA_UEKEK_STR-AKSTOPGR sy-vline
WA_UEKEK_STR-KZ sy-vline
WA_UEKEK_STR-EKKOWAERS sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.