ABAP Select data from SAP table UCU_SX_ACC_SCR_DATA_INT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP UCU_SX_ACC_SCR_DATA_INT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to UCU_SX_ACC_SCR_DATA_INT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the UCU_SX_ACC_SCR_DATA_INT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_UCU_SX_ACC_SCR_DATA_INT TYPE STANDARD TABLE OF UCU_SX_ACC_SCR_DATA_INT,
      WA_UCU_SX_ACC_SCR_DATA_INT TYPE UCU_SX_ACC_SCR_DATA_INT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <UCU_SX_ACC_SCR_DATA_INT> TYPE UCU_SX_ACC_SCR_DATA_INT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_UCU_SX_ACC_SCR_DATA_INT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM UCU_SX_ACC_SCR_DATA_INT
  INTO TABLE IT_UCU_SX_ACC_SCR_DATA_INT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM UCU_SX_ACC_SCR_DATA_INT
*  INTO TABLE @DATA(IT_UCU_SX_ACC_SCR_DATA_INT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_UCU_SX_ACC_SCR_DATA_INT INDEX 1 INTO DATA(WA_UCU_SX_ACC_SCR_DATA_INT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_UCU_SX_ACC_SCR_DATA_INT ASSIGNING <UCU_SX_ACC_SCR_DATA_INT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<UCU_SX_ACC_SCR_DATA_INT>-TYPE1 = 1.
<UCU_SX_ACC_SCR_DATA_INT>-ICON1 = 1.
<UCU_SX_ACC_SCR_DATA_INT>-VALUE1 = 1.
<UCU_SX_ACC_SCR_DATA_INT>-VALUE21 = 1.
<UCU_SX_ACC_SCR_DATA_INT>-FNAME_SUBST1 = 1.
ENDLOOP.

LOOP AT IT_UCU_SX_ACC_SCR_DATA_INT INTO WA_UCU_SX_ACC_SCR_DATA_INT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_UCU_SX_ACC_SCR_DATA_INT-ATTR_SUBST1, sy-vline,
WA_UCU_SX_ACC_SCR_DATA_INT-SETID1, sy-vline,
WA_UCU_SX_ACC_SCR_DATA_INT-SISELID1, sy-vline,
WA_UCU_SX_ACC_SCR_DATA_INT-T_SUBCOMP1, sy-vline,
WA_UCU_SX_ACC_SCR_DATA_INT-DEFLT1, sy-vline,
WA_UCU_SX_ACC_SCR_DATA_INT-TYPE2, sy-vline.
ENDLOOP. *Add any further fields from structure WA_UCU_SX_ACC_SCR_DATA_INT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_UCU_SX_ACC_SCR_DATA_INT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_UCU_SX_ACC_SCR_DATA_INT INTO WA_UCU_SX_ACC_SCR_DATA_INT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_UCU_SX_ACC_SCR_DATA_INT_STR,
TYPE1 TYPE STRING,
ICON1 TYPE STRING,
VALUE1 TYPE STRING,
VALUE21 TYPE STRING,
FNAME_SUBST1 TYPE STRING,
ATTR_SUBST1 TYPE STRING,
SETID1 TYPE STRING,
SISELID1 TYPE STRING,
T_SUBCOMP1 TYPE STRING,
DEFLT1 TYPE STRING,
TYPE2 TYPE STRING,
ICON2 TYPE STRING,
VALUE2 TYPE STRING,
VALUE22 TYPE STRING,
FNAME_SUBST2 TYPE STRING,
ATTR_SUBST2 TYPE STRING,
SETID2 TYPE STRING,
SISELID2 TYPE STRING,
T_SUBCOMP2 TYPE STRING,
DEFLT2 TYPE STRING,
TYPE3 TYPE STRING,
ICON3 TYPE STRING,
VALUE3 TYPE STRING,
VALUE23 TYPE STRING,
FNAME_SUBST3 TYPE STRING,
ATTR_SUBST3 TYPE STRING,
SETID3 TYPE STRING,
SISELID3 TYPE STRING,
T_SUBCOMP3 TYPE STRING,
DEFLT3 TYPE STRING,
TYPE4 TYPE STRING,
ICON4 TYPE STRING,
VALUE4 TYPE STRING,
VALUE24 TYPE STRING,
FNAME_SUBST4 TYPE STRING,
ATTR_SUBST4 TYPE STRING,
SETID4 TYPE STRING,
SISELID4 TYPE STRING,
T_SUBCOMP4 TYPE STRING,
DEFLT4 TYPE STRING,
TYPE5 TYPE STRING,
ICON5 TYPE STRING,
VALUE5 TYPE STRING,
VALUE25 TYPE STRING,
FNAME_SUBST5 TYPE STRING,
ATTR_SUBST5 TYPE STRING,
SETID5 TYPE STRING,
SISELID5 TYPE STRING,
T_SUBCOMP5 TYPE STRING,
DEFLT5 TYPE STRING,
FIELDNAME TYPE STRING,
HANDLE TYPE STRING,
SEQNR TYPE STRING,END OF T_EKKO_STR. DATA: WA_UCU_SX_ACC_SCR_DATA_INT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_UCU_SX_ACC_SCR_DATA_INT_STR-TYPE1 sy-vline
WA_UCU_SX_ACC_SCR_DATA_INT_STR-ICON1 sy-vline
WA_UCU_SX_ACC_SCR_DATA_INT_STR-VALUE1 sy-vline
WA_UCU_SX_ACC_SCR_DATA_INT_STR-VALUE21 sy-vline
WA_UCU_SX_ACC_SCR_DATA_INT_STR-FNAME_SUBST1 sy-vline
WA_UCU_SX_ACC_SCR_DATA_INT_STR-ATTR_SUBST1 sy-vline
WA_UCU_SX_ACC_SCR_DATA_INT_STR-SETID1 sy-vline
WA_UCU_SX_ACC_SCR_DATA_INT_STR-SISELID1 sy-vline
WA_UCU_SX_ACC_SCR_DATA_INT_STR-T_SUBCOMP1 sy-vline
WA_UCU_SX_ACC_SCR_DATA_INT_STR-DEFLT1 sy-vline
WA_UCU_SX_ACC_SCR_DATA_INT_STR-TYPE2 sy-vline
WA_UCU_SX_ACC_SCR_DATA_INT_STR-ICON2 sy-vline
WA_UCU_SX_ACC_SCR_DATA_INT_STR-VALUE2 sy-vline
WA_UCU_SX_ACC_SCR_DATA_INT_STR-VALUE22 sy-vline
WA_UCU_SX_ACC_SCR_DATA_INT_STR-FNAME_SUBST2 sy-vline
WA_UCU_SX_ACC_SCR_DATA_INT_STR-ATTR_SUBST2 sy-vline
WA_UCU_SX_ACC_SCR_DATA_INT_STR-SETID2 sy-vline
WA_UCU_SX_ACC_SCR_DATA_INT_STR-SISELID2 sy-vline
WA_UCU_SX_ACC_SCR_DATA_INT_STR-T_SUBCOMP2 sy-vline
WA_UCU_SX_ACC_SCR_DATA_INT_STR-DEFLT2 sy-vline
WA_UCU_SX_ACC_SCR_DATA_INT_STR-TYPE3 sy-vline
WA_UCU_SX_ACC_SCR_DATA_INT_STR-ICON3 sy-vline
WA_UCU_SX_ACC_SCR_DATA_INT_STR-VALUE3 sy-vline
WA_UCU_SX_ACC_SCR_DATA_INT_STR-VALUE23 sy-vline
WA_UCU_SX_ACC_SCR_DATA_INT_STR-FNAME_SUBST3 sy-vline
WA_UCU_SX_ACC_SCR_DATA_INT_STR-ATTR_SUBST3 sy-vline
WA_UCU_SX_ACC_SCR_DATA_INT_STR-SETID3 sy-vline
WA_UCU_SX_ACC_SCR_DATA_INT_STR-SISELID3 sy-vline
WA_UCU_SX_ACC_SCR_DATA_INT_STR-T_SUBCOMP3 sy-vline
WA_UCU_SX_ACC_SCR_DATA_INT_STR-DEFLT3 sy-vline
WA_UCU_SX_ACC_SCR_DATA_INT_STR-TYPE4 sy-vline
WA_UCU_SX_ACC_SCR_DATA_INT_STR-ICON4 sy-vline
WA_UCU_SX_ACC_SCR_DATA_INT_STR-VALUE4 sy-vline
WA_UCU_SX_ACC_SCR_DATA_INT_STR-VALUE24 sy-vline
WA_UCU_SX_ACC_SCR_DATA_INT_STR-FNAME_SUBST4 sy-vline
WA_UCU_SX_ACC_SCR_DATA_INT_STR-ATTR_SUBST4 sy-vline
WA_UCU_SX_ACC_SCR_DATA_INT_STR-SETID4 sy-vline
WA_UCU_SX_ACC_SCR_DATA_INT_STR-SISELID4 sy-vline
WA_UCU_SX_ACC_SCR_DATA_INT_STR-T_SUBCOMP4 sy-vline
WA_UCU_SX_ACC_SCR_DATA_INT_STR-DEFLT4 sy-vline
WA_UCU_SX_ACC_SCR_DATA_INT_STR-TYPE5 sy-vline
WA_UCU_SX_ACC_SCR_DATA_INT_STR-ICON5 sy-vline
WA_UCU_SX_ACC_SCR_DATA_INT_STR-VALUE5 sy-vline
WA_UCU_SX_ACC_SCR_DATA_INT_STR-VALUE25 sy-vline
WA_UCU_SX_ACC_SCR_DATA_INT_STR-FNAME_SUBST5 sy-vline
WA_UCU_SX_ACC_SCR_DATA_INT_STR-ATTR_SUBST5 sy-vline
WA_UCU_SX_ACC_SCR_DATA_INT_STR-SETID5 sy-vline
WA_UCU_SX_ACC_SCR_DATA_INT_STR-SISELID5 sy-vline
WA_UCU_SX_ACC_SCR_DATA_INT_STR-T_SUBCOMP5 sy-vline
WA_UCU_SX_ACC_SCR_DATA_INT_STR-DEFLT5 sy-vline
WA_UCU_SX_ACC_SCR_DATA_INT_STR-FIELDNAME sy-vline
WA_UCU_SX_ACC_SCR_DATA_INT_STR-HANDLE sy-vline
WA_UCU_SX_ACC_SCR_DATA_INT_STR-SEQNR sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.