ABAP Select data from SAP table UCD_SX_TX_DC_DOCNR_RETURN into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP UCD_SX_TX_DC_DOCNR_RETURN table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to UCD_SX_TX_DC_DOCNR_RETURN. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the UCD_SX_TX_DC_DOCNR_RETURN table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_UCD_SX_TX_DC_DOCNR_RETURN TYPE STANDARD TABLE OF UCD_SX_TX_DC_DOCNR_RETURN, WA_UCD_SX_TX_DC_DOCNR_RETURN TYPE UCD_SX_TX_DC_DOCNR_RETURN, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <UCD_SX_TX_DC_DOCNR_RETURN> TYPE UCD_SX_TX_DC_DOCNR_RETURN. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_UCD_SX_TX_DC_DOCNR_RETURN. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM UCD_SX_TX_DC_DOCNR_RETURN INTO TABLE IT_UCD_SX_TX_DC_DOCNR_RETURN. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM UCD_SX_TX_DC_DOCNR_RETURN * INTO TABLE @DATA(IT_UCD_SX_TX_DC_DOCNR_RETURN2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_UCD_SX_TX_DC_DOCNR_RETURN INDEX 1 INTO DATA(WA_UCD_SX_TX_DC_DOCNR_RETURN2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_UCD_SX_TX_DC_DOCNR_RETURN ASSIGNING <UCD_SX_TX_DC_DOCNR_RETURN>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<UCD_SX_TX_DC_DOCNR_RETURN>-INCLUDES_DOCKEY = 1.
<UCD_SX_TX_DC_DOCNR_RETURN>-INCLUDE__1 = 1.
<UCD_SX_TX_DC_DOCNR_RETURN>-DUMMY = 1.
<UCD_SX_TX_DC_DOCNR_RETURN>-INCLUDE__2 = 1.
<UCD_SX_TX_DC_DOCNR_RETURN>-DUMMY = 1.
ENDLOOP. LOOP AT IT_UCD_SX_TX_DC_DOCNR_RETURN INTO WA_UCD_SX_TX_DC_DOCNR_RETURN. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_UCD_SX_TX_DC_DOCNR_RETURN-INCLUDE__3, sy-vline,
WA_UCD_SX_TX_DC_DOCNR_RETURN-DUMMY, sy-vline,
WA_UCD_SX_TX_DC_DOCNR_RETURN-DOCNR_TEMP, sy-vline,
WA_UCD_SX_TX_DC_DOCNR_RETURN-INCLUDE1, sy-vline,
WA_UCD_SX_TX_DC_DOCNR_RETURN-DUMMY, sy-vline,
ENDLOOP. *Add any further fields from structure WA_UCD_SX_TX_DC_DOCNR_RETURN you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_UCD_SX_TX_DC_DOCNR_RETURN TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_UCD_SX_TX_DC_DOCNR_RETURN INTO WA_UCD_SX_TX_DC_DOCNR_RETURN. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field DOCNR_TEMP CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_UCD_SX_TX_DC_DOCNR_RETURN-DOCNR_TEMP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_UCD_SX_TX_DC_DOCNR_RETURN-DOCNR_TEMP.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_UCD_SX_TX_DC_DOCNR_RETURN_STR,
INCLUDES_DOCKEY TYPE STRING,
INCLUDE__1 TYPE STRING,
DUMMY TYPE STRING,
INCLUDE__2 TYPE STRING,
DUMMY TYPE STRING,
INCLUDE__3 TYPE STRING,
DUMMY TYPE STRING,
DOCNR_TEMP TYPE STRING,
INCLUDE1 TYPE STRING,
DUMMY TYPE STRING,END OF T_EKKO_STR. DATA: WA_UCD_SX_TX_DC_DOCNR_RETURN_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_UCD_SX_TX_DC_DOCNR_RETURN_STR-INCLUDES_DOCKEY sy-vline
WA_UCD_SX_TX_DC_DOCNR_RETURN_STR-INCLUDE__1 sy-vline
WA_UCD_SX_TX_DC_DOCNR_RETURN_STR-DUMMY sy-vline
WA_UCD_SX_TX_DC_DOCNR_RETURN_STR-INCLUDE__2 sy-vline
WA_UCD_SX_TX_DC_DOCNR_RETURN_STR-DUMMY sy-vline
WA_UCD_SX_TX_DC_DOCNR_RETURN_STR-INCLUDE__3 sy-vline
WA_UCD_SX_TX_DC_DOCNR_RETURN_STR-DUMMY sy-vline
WA_UCD_SX_TX_DC_DOCNR_RETURN_STR-DOCNR_TEMP sy-vline
WA_UCD_SX_TX_DC_DOCNR_RETURN_STR-INCLUDE1 sy-vline
WA_UCD_SX_TX_DC_DOCNR_RETURN_STR-DUMMY sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.