ABAP Select data from SAP table UBC_TB_INVP into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP UBC_TB_INVP table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to UBC_TB_INVP. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the UBC_TB_INVP table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_UBC_TB_INVP TYPE STANDARD TABLE OF UBC_TB_INVP,
      WA_UBC_TB_INVP TYPE UBC_TB_INVP,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <UBC_TB_INVP> TYPE UBC_TB_INVP.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_UBC_TB_INVP.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM UBC_TB_INVP
  INTO TABLE IT_UBC_TB_INVP.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM UBC_TB_INVP
*  INTO TABLE @DATA(IT_UBC_TB_INVP2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_UBC_TB_INVP INDEX 1 INTO DATA(WA_UBC_TB_INVP2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_UBC_TB_INVP ASSIGNING <UBC_TB_INVP>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<UBC_TB_INVP>-MANDT = 1.
<UBC_TB_INVP>-ORG = 1.
<UBC_TB_INVP>-DOCNUM = 1.
<UBC_TB_INVP>-POSNR = 1.
<UBC_TB_INVP>-POSEX = 1.
ENDLOOP.

LOOP AT IT_UBC_TB_INVP INTO WA_UBC_TB_INVP.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_UBC_TB_INVP-SGTXT, sy-vline,
WA_UBC_TB_INVP-WRBTR, sy-vline,
WA_UBC_TB_INVP-RPA, sy-vline,
WA_UBC_TB_INVP-MWSTPRZ, sy-vline,
WA_UBC_TB_INVP-MWSTBTR, sy-vline,
WA_UBC_TB_INVP-MWSTTXT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_UBC_TB_INVP you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_UBC_TB_INVP TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_UBC_TB_INVP INTO WA_UBC_TB_INVP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit AU132, internal->external for field WRBTR CALL FUNCTION 'CONVERSION_EXIT_AU132_OUTPUT' EXPORTING input = WA_UBC_TB_INVP-WRBTR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_UBC_TB_INVP-WRBTR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AU132, internal->external for field MWSTBTR CALL FUNCTION 'CONVERSION_EXIT_AU132_OUTPUT' EXPORTING input = WA_UBC_TB_INVP-MWSTBTR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_UBC_TB_INVP-MWSTBTR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_UBC_TB_INVP_STR,
MANDT TYPE STRING,
ORG TYPE STRING,
DOCNUM TYPE STRING,
POSNR TYPE STRING,
POSEX TYPE STRING,
SGTXT TYPE STRING,
WRBTR TYPE STRING,
RPA TYPE STRING,
MWSTPRZ TYPE STRING,
MWSTBTR TYPE STRING,
MWSTTXT TYPE STRING,END OF T_EKKO_STR. DATA: WA_UBC_TB_INVP_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_UBC_TB_INVP_STR-MANDT sy-vline
WA_UBC_TB_INVP_STR-ORG sy-vline
WA_UBC_TB_INVP_STR-DOCNUM sy-vline
WA_UBC_TB_INVP_STR-POSNR sy-vline
WA_UBC_TB_INVP_STR-POSEX sy-vline
WA_UBC_TB_INVP_STR-SGTXT sy-vline
WA_UBC_TB_INVP_STR-WRBTR sy-vline
WA_UBC_TB_INVP_STR-RPA sy-vline
WA_UBC_TB_INVP_STR-MWSTPRZ sy-vline
WA_UBC_TB_INVP_STR-MWSTBTR sy-vline
WA_UBC_TB_INVP_STR-MWSTTXT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.