ABAP Select data from SAP table UAV0PRICE004H into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP UAV0PRICE004H table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to UAV0PRICE004H. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the UAV0PRICE004H table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_UAV0PRICE004H TYPE STANDARD TABLE OF UAV0PRICE004H,
      WA_UAV0PRICE004H TYPE UAV0PRICE004H,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <UAV0PRICE004H> TYPE UAV0PRICE004H.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_UAV0PRICE004H.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM UAV0PRICE004H
  INTO TABLE IT_UAV0PRICE004H.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM UAV0PRICE004H
*  INTO TABLE @DATA(IT_UAV0PRICE004H2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_UAV0PRICE004H INDEX 1 INTO DATA(WA_UAV0PRICE004H2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_UAV0PRICE004H ASSIGNING <UAV0PRICE004H>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<UAV0PRICE004H>-CLIENT = 1.
<UAV0PRICE004H>-FOBJ_OBJECT_ID = 1.
<UAV0PRICE004H>-ACC_SYSTEM = 1.
<UAV0PRICE004H>-FIN_PRCVARIANT = 1.
<UAV0PRICE004H>-FIN_PRICELABEL = 1.
ENDLOOP.

LOOP AT IT_UAV0PRICE004H INTO WA_UAV0PRICE004H.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_UAV0PRICE004H-FIN_FROMDAT, sy-vline,
WA_UAV0PRICE004H-FIN_CURRTYPE, sy-vline,
WA_UAV0PRICE004H-TIMESTAMPL, sy-vline,
WA_UAV0PRICE004H-FIN_PRICE, sy-vline,
WA_UAV0PRICE004H-FIN_PRCFIX, sy-vline,
WA_UAV0PRICE004H-FIN_CURRENCY, sy-vline.
ENDLOOP. *Add any further fields from structure WA_UAV0PRICE004H you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_UAV0PRICE004H TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_UAV0PRICE004H INTO WA_UAV0PRICE004H. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field FIN_CURRTYPE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_UAV0PRICE004H-FIN_CURRTYPE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_UAV0PRICE004H-FIN_CURRTYPE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field FIN_UOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_UAV0PRICE004H-FIN_UOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_UAV0PRICE004H-FIN_UOM.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_UAV0PRICE004H_STR,
CLIENT TYPE STRING,
FOBJ_OBJECT_ID TYPE STRING,
ACC_SYSTEM TYPE STRING,
FIN_PRCVARIANT TYPE STRING,
FIN_PRICELABEL TYPE STRING,
FIN_FROMDAT TYPE STRING,
FIN_CURRTYPE TYPE STRING,
TIMESTAMPL TYPE STRING,
FIN_PRICE TYPE STRING,
FIN_PRCFIX TYPE STRING,
FIN_CURRENCY TYPE STRING,
FIN_PRCBASE TYPE STRING,
FIN_UOM TYPE STRING,
FINB_SND_ID TYPE STRING,
FINB_SNDKEY TYPE STRING,
FIN_TODAT TYPE STRING,
UNAME TYPE STRING,
TCODE TYPE STRING,
FIN_PRCDELETIND TYPE STRING,
FIN_PRCINVCHGIND TYPE STRING,
FOBJ_TYPE_NAME TYPE STRING,
CPROG TYPE STRING,END OF T_EKKO_STR. DATA: WA_UAV0PRICE004H_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_UAV0PRICE004H_STR-CLIENT sy-vline
WA_UAV0PRICE004H_STR-FOBJ_OBJECT_ID sy-vline
WA_UAV0PRICE004H_STR-ACC_SYSTEM sy-vline
WA_UAV0PRICE004H_STR-FIN_PRCVARIANT sy-vline
WA_UAV0PRICE004H_STR-FIN_PRICELABEL sy-vline
WA_UAV0PRICE004H_STR-FIN_FROMDAT sy-vline
WA_UAV0PRICE004H_STR-FIN_CURRTYPE sy-vline
WA_UAV0PRICE004H_STR-TIMESTAMPL sy-vline
WA_UAV0PRICE004H_STR-FIN_PRICE sy-vline
WA_UAV0PRICE004H_STR-FIN_PRCFIX sy-vline
WA_UAV0PRICE004H_STR-FIN_CURRENCY sy-vline
WA_UAV0PRICE004H_STR-FIN_PRCBASE sy-vline
WA_UAV0PRICE004H_STR-FIN_UOM sy-vline
WA_UAV0PRICE004H_STR-FINB_SND_ID sy-vline
WA_UAV0PRICE004H_STR-FINB_SNDKEY sy-vline
WA_UAV0PRICE004H_STR-FIN_TODAT sy-vline
WA_UAV0PRICE004H_STR-UNAME sy-vline
WA_UAV0PRICE004H_STR-TCODE sy-vline
WA_UAV0PRICE004H_STR-FIN_PRCDELETIND sy-vline
WA_UAV0PRICE004H_STR-FIN_PRCINVCHGIND sy-vline
WA_UAV0PRICE004H_STR-FOBJ_TYPE_NAME sy-vline
WA_UAV0PRICE004H_STR-CPROG sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.