ABAP Select data from SAP table UAI_S_INTERMEDIATE_CALCULATION into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP UAI_S_INTERMEDIATE_CALCULATION table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to UAI_S_INTERMEDIATE_CALCULATION. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the UAI_S_INTERMEDIATE_CALCULATION table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_UAI_S_INTERMEDIATE_CALCULATION TYPE STANDARD TABLE OF UAI_S_INTERMEDIATE_CALCULATION,
      WA_UAI_S_INTERMEDIATE_CALCULATION TYPE UAI_S_INTERMEDIATE_CALCULATION,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <UAI_S_INTERMEDIATE_CALCULATION> TYPE UAI_S_INTERMEDIATE_CALCULATION.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_UAI_S_INTERMEDIATE_CALCULATION.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM UAI_S_INTERMEDIATE_CALCULATION
  INTO TABLE IT_UAI_S_INTERMEDIATE_CALCULATION.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM UAI_S_INTERMEDIATE_CALCULATION
*  INTO TABLE @DATA(IT_UAI_S_INTERMEDIATE_CALCULATION2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_UAI_S_INTERMEDIATE_CALCULATION INDEX 1 INTO DATA(WA_UAI_S_INTERMEDIATE_CALCULATION2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_UAI_S_INTERMEDIATE_CALCULATION ASSIGNING <UAI_S_INTERMEDIATE_CALCULATION>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<UAI_S_INTERMEDIATE_CALCULATION>-FOBJ_TYPE_NAME = 1.
<UAI_S_INTERMEDIATE_CALCULATION>-FOBJ_OBJECT_ID = 1.
<UAI_S_INTERMEDIATE_CALCULATION>-FOBJ_TYPE_NAME_P = 1.
<UAI_S_INTERMEDIATE_CALCULATION>-FOBJ_OBJECT_ID_P = 1.
<UAI_S_INTERMEDIATE_CALCULATION>-FIN_TECHDOCNO = 1.
ENDLOOP.

LOOP AT IT_UAI_S_INTERMEDIATE_CALCULATION INTO WA_UAI_S_INTERMEDIATE_CALCULATION.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_UAI_S_INTERMEDIATE_CALCULATION-FIN_ITEMNO, sy-vline,
WA_UAI_S_INTERMEDIATE_CALCULATION-FIN_POSTDAT, sy-vline,
WA_UAI_S_INTERMEDIATE_CALCULATION-DATUM, sy-vline,
WA_UAI_S_INTERMEDIATE_CALCULATION-UZEIT, sy-vline,
WA_UAI_S_INTERMEDIATE_CALCULATION-FIN_AMTTRA, sy-vline,
WA_UAI_S_INTERMEDIATE_CALCULATION-FIN_AMTCOMP, sy-vline.
ENDLOOP. *Add any further fields from structure WA_UAI_S_INTERMEDIATE_CALCULATION you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_UAI_S_INTERMEDIATE_CALCULATION TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_UAI_S_INTERMEDIATE_CALCULATION INTO WA_UAI_S_INTERMEDIATE_CALCULATION. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field FIN_ITEMNO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_UAI_S_INTERMEDIATE_CALCULATION-FIN_ITEMNO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_UAI_S_INTERMEDIATE_CALCULATION-FIN_ITEMNO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field FIN_UOMVAL CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_UAI_S_INTERMEDIATE_CALCULATION-FIN_UOMVAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_UAI_S_INTERMEDIATE_CALCULATION-FIN_UOMVAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field FIN_UOMORD CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_UAI_S_INTERMEDIATE_CALCULATION-FIN_UOMORD IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_UAI_S_INTERMEDIATE_CALCULATION-FIN_UOMORD.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_UAI_S_INTERMEDIATE_CALCULATION_STR,
FOBJ_TYPE_NAME TYPE STRING,
FOBJ_OBJECT_ID TYPE STRING,
FOBJ_TYPE_NAME_P TYPE STRING,
FOBJ_OBJECT_ID_P TYPE STRING,
FIN_TECHDOCNO TYPE STRING,
FIN_ITEMNO TYPE STRING,
FIN_POSTDAT TYPE STRING,
DATUM TYPE STRING,
UZEIT TYPE STRING,
FIN_AMTTRA TYPE STRING,
FIN_AMTCOMP TYPE STRING,
FIN_AMTACCSYS TYPE STRING,
FIN_AMTHARD TYPE STRING,
FIN_AMTINDEX TYPE STRING,
FIN_AMTCOMPGLOB TYPE STRING,
FAI_T_OPERATORS TYPE STRING,
FIN_QTYVAL TYPE STRING,
FAI_QTYVAL_TOT TYPE STRING,
FIN_UOMVAL TYPE STRING,
FIN_QTYORD TYPE STRING,
FAI_QTYORD_TOT TYPE STRING,
FIN_UOMORD TYPE STRING,
FAI_T_QUANTITY_OPERATORS TYPE STRING,
FAI_AMTTRA_RESULT TYPE STRING,
FIN_CURRTRA TYPE STRING,
FAI_AMTCOMP_RESULT TYPE STRING,
FIN_CURRCOMP TYPE STRING,
FAI_AMTACCSYS_RESULT TYPE STRING,
FIN_CURRACCSYS TYPE STRING,
FAI_AMTHARD_RESULT TYPE STRING,
FIN_CURRHARD TYPE STRING,
FAI_AMTINDEX_RESULT TYPE STRING,
FIN_CURRINDEX TYPE STRING,
FAI_AMTCOMPGLOB_RESULT TYPE STRING,
FIN_CURRCOMPGLOB TYPE STRING,
FAI_QTYVAL_RESULT TYPE STRING,END OF T_EKKO_STR. DATA: WA_UAI_S_INTERMEDIATE_CALCULATION_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_UAI_S_INTERMEDIATE_CALCULATION_STR-FOBJ_TYPE_NAME sy-vline
WA_UAI_S_INTERMEDIATE_CALCULATION_STR-FOBJ_OBJECT_ID sy-vline
WA_UAI_S_INTERMEDIATE_CALCULATION_STR-FOBJ_TYPE_NAME_P sy-vline
WA_UAI_S_INTERMEDIATE_CALCULATION_STR-FOBJ_OBJECT_ID_P sy-vline
WA_UAI_S_INTERMEDIATE_CALCULATION_STR-FIN_TECHDOCNO sy-vline
WA_UAI_S_INTERMEDIATE_CALCULATION_STR-FIN_ITEMNO sy-vline
WA_UAI_S_INTERMEDIATE_CALCULATION_STR-FIN_POSTDAT sy-vline
WA_UAI_S_INTERMEDIATE_CALCULATION_STR-DATUM sy-vline
WA_UAI_S_INTERMEDIATE_CALCULATION_STR-UZEIT sy-vline
WA_UAI_S_INTERMEDIATE_CALCULATION_STR-FIN_AMTTRA sy-vline
WA_UAI_S_INTERMEDIATE_CALCULATION_STR-FIN_AMTCOMP sy-vline
WA_UAI_S_INTERMEDIATE_CALCULATION_STR-FIN_AMTACCSYS sy-vline
WA_UAI_S_INTERMEDIATE_CALCULATION_STR-FIN_AMTHARD sy-vline
WA_UAI_S_INTERMEDIATE_CALCULATION_STR-FIN_AMTINDEX sy-vline
WA_UAI_S_INTERMEDIATE_CALCULATION_STR-FIN_AMTCOMPGLOB sy-vline
WA_UAI_S_INTERMEDIATE_CALCULATION_STR-FAI_T_OPERATORS sy-vline
WA_UAI_S_INTERMEDIATE_CALCULATION_STR-FIN_QTYVAL sy-vline
WA_UAI_S_INTERMEDIATE_CALCULATION_STR-FAI_QTYVAL_TOT sy-vline
WA_UAI_S_INTERMEDIATE_CALCULATION_STR-FIN_UOMVAL sy-vline
WA_UAI_S_INTERMEDIATE_CALCULATION_STR-FIN_QTYORD sy-vline
WA_UAI_S_INTERMEDIATE_CALCULATION_STR-FAI_QTYORD_TOT sy-vline
WA_UAI_S_INTERMEDIATE_CALCULATION_STR-FIN_UOMORD sy-vline
WA_UAI_S_INTERMEDIATE_CALCULATION_STR-FAI_T_QUANTITY_OPERATORS sy-vline
WA_UAI_S_INTERMEDIATE_CALCULATION_STR-FAI_AMTTRA_RESULT sy-vline
WA_UAI_S_INTERMEDIATE_CALCULATION_STR-FIN_CURRTRA sy-vline
WA_UAI_S_INTERMEDIATE_CALCULATION_STR-FAI_AMTCOMP_RESULT sy-vline
WA_UAI_S_INTERMEDIATE_CALCULATION_STR-FIN_CURRCOMP sy-vline
WA_UAI_S_INTERMEDIATE_CALCULATION_STR-FAI_AMTACCSYS_RESULT sy-vline
WA_UAI_S_INTERMEDIATE_CALCULATION_STR-FIN_CURRACCSYS sy-vline
WA_UAI_S_INTERMEDIATE_CALCULATION_STR-FAI_AMTHARD_RESULT sy-vline
WA_UAI_S_INTERMEDIATE_CALCULATION_STR-FIN_CURRHARD sy-vline
WA_UAI_S_INTERMEDIATE_CALCULATION_STR-FAI_AMTINDEX_RESULT sy-vline
WA_UAI_S_INTERMEDIATE_CALCULATION_STR-FIN_CURRINDEX sy-vline
WA_UAI_S_INTERMEDIATE_CALCULATION_STR-FAI_AMTCOMPGLOB_RESULT sy-vline
WA_UAI_S_INTERMEDIATE_CALCULATION_STR-FIN_CURRCOMPGLOB sy-vline
WA_UAI_S_INTERMEDIATE_CALCULATION_STR-FAI_QTYVAL_RESULT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.