ABAP Select data from SAP table UAB_S_IPPE_RESULT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP UAB_S_IPPE_RESULT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to UAB_S_IPPE_RESULT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the UAB_S_IPPE_RESULT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_UAB_S_IPPE_RESULT TYPE STANDARD TABLE OF UAB_S_IPPE_RESULT,
      WA_UAB_S_IPPE_RESULT TYPE UAB_S_IPPE_RESULT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <UAB_S_IPPE_RESULT> TYPE UAB_S_IPPE_RESULT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_UAB_S_IPPE_RESULT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM UAB_S_IPPE_RESULT
  INTO TABLE IT_UAB_S_IPPE_RESULT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM UAB_S_IPPE_RESULT
*  INTO TABLE @DATA(IT_UAB_S_IPPE_RESULT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_UAB_S_IPPE_RESULT INDEX 1 INTO DATA(WA_UAB_S_IPPE_RESULT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_UAB_S_IPPE_RESULT ASSIGNING <UAB_S_IPPE_RESULT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<UAB_S_IPPE_RESULT>-MANDT = 1.
<UAB_S_IPPE_RESULT>-PVGUID = 1.
<UAB_S_IPPE_RESULT>-PVNAME = 1.
<UAB_S_IPPE_RESULT>-PVCNT = 1.
<UAB_S_IPPE_RESULT>-PNGUID = 1.
ENDLOOP.

LOOP AT IT_UAB_S_IPPE_RESULT INTO WA_UAB_S_IPPE_RESULT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_UAB_S_IPPE_RESULT-CMPID, sy-vline,
WA_UAB_S_IPPE_RESULT-FLG_DFT_EFF, sy-vline,
WA_UAB_S_IPPE_RESULT-FLG_NO_DATE, sy-vline,
WA_UAB_S_IPPE_RESULT-FLG_HIGHLANDER, sy-vline,
WA_UAB_S_IPPE_RESULT-FLG_MANDATORY, sy-vline,
WA_UAB_S_IPPE_RESULT-FLG_STD_PART, sy-vline.
ENDLOOP. *Add any further fields from structure WA_UAB_S_IPPE_RESULT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_UAB_S_IPPE_RESULT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_UAB_S_IPPE_RESULT INTO WA_UAB_S_IPPE_RESULT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_UAB_S_IPPE_RESULT_STR,
MANDT TYPE STRING,
PVGUID TYPE STRING,
PVNAME TYPE STRING,
PVCNT TYPE STRING,
PNGUID TYPE STRING,
CMPID TYPE STRING,
FLG_DFT_EFF TYPE STRING,
FLG_NO_DATE TYPE STRING,
FLG_HIGHLANDER TYPE STRING,
FLG_MANDATORY TYPE STRING,
FLG_STD_PART TYPE STRING,
FLG_SUP_DEL TYPE STRING,
PVCPRIO TYPE STRING,
IS_COLOR_NODE TYPE STRING,
PGUID TYPE STRING,
CCODE TYPE STRING,
QUANT TYPE STRING,
QUNIT TYPE STRING,
QUANT_FIX TYPE STRING,
PRIO TYPE STRING,
ACTID TYPE STRING,
IOIND TYPE STRING,
ERROR TYPE STRING,
MATCO TYPE STRING,
ALTGRP TYPE STRING,
PVCTYPE TYPE STRING,
CREADAT TYPE STRING,
KZKFG TYPE STRING,
STDPD TYPE STRING,
DATE_FROM TYPE STRING,
DATE_TO TYPE STRING,
AENNRDATE TYPE STRING,
QUANT_1000 TYPE STRING,END OF T_EKKO_STR. DATA: WA_UAB_S_IPPE_RESULT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_UAB_S_IPPE_RESULT_STR-MANDT sy-vline
WA_UAB_S_IPPE_RESULT_STR-PVGUID sy-vline
WA_UAB_S_IPPE_RESULT_STR-PVNAME sy-vline
WA_UAB_S_IPPE_RESULT_STR-PVCNT sy-vline
WA_UAB_S_IPPE_RESULT_STR-PNGUID sy-vline
WA_UAB_S_IPPE_RESULT_STR-CMPID sy-vline
WA_UAB_S_IPPE_RESULT_STR-FLG_DFT_EFF sy-vline
WA_UAB_S_IPPE_RESULT_STR-FLG_NO_DATE sy-vline
WA_UAB_S_IPPE_RESULT_STR-FLG_HIGHLANDER sy-vline
WA_UAB_S_IPPE_RESULT_STR-FLG_MANDATORY sy-vline
WA_UAB_S_IPPE_RESULT_STR-FLG_STD_PART sy-vline
WA_UAB_S_IPPE_RESULT_STR-FLG_SUP_DEL sy-vline
WA_UAB_S_IPPE_RESULT_STR-PVCPRIO sy-vline
WA_UAB_S_IPPE_RESULT_STR-IS_COLOR_NODE sy-vline
WA_UAB_S_IPPE_RESULT_STR-PGUID sy-vline
WA_UAB_S_IPPE_RESULT_STR-CCODE sy-vline
WA_UAB_S_IPPE_RESULT_STR-QUANT sy-vline
WA_UAB_S_IPPE_RESULT_STR-QUNIT sy-vline
WA_UAB_S_IPPE_RESULT_STR-QUANT_FIX sy-vline
WA_UAB_S_IPPE_RESULT_STR-PRIO sy-vline
WA_UAB_S_IPPE_RESULT_STR-ACTID sy-vline
WA_UAB_S_IPPE_RESULT_STR-IOIND sy-vline
WA_UAB_S_IPPE_RESULT_STR-ERROR sy-vline
WA_UAB_S_IPPE_RESULT_STR-MATCO sy-vline
WA_UAB_S_IPPE_RESULT_STR-ALTGRP sy-vline
WA_UAB_S_IPPE_RESULT_STR-PVCTYPE sy-vline
WA_UAB_S_IPPE_RESULT_STR-CREADAT sy-vline
WA_UAB_S_IPPE_RESULT_STR-KZKFG sy-vline
WA_UAB_S_IPPE_RESULT_STR-STDPD sy-vline
WA_UAB_S_IPPE_RESULT_STR-DATE_FROM sy-vline
WA_UAB_S_IPPE_RESULT_STR-DATE_TO sy-vline
WA_UAB_S_IPPE_RESULT_STR-AENNRDATE sy-vline
WA_UAB_S_IPPE_RESULT_STR-QUANT_1000 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.