ABAP Select data from SAP table U_37130C into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP U_37130C table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to U_37130C. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the U_37130C table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_U_37130C TYPE STANDARD TABLE OF U_37130C,
      WA_U_37130C TYPE U_37130C,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <U_37130C> TYPE U_37130C.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_U_37130C.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM U_37130C
  INTO TABLE IT_U_37130C.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM U_37130C
*  INTO TABLE @DATA(IT_U_37130C2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_U_37130C INDEX 1 INTO DATA(WA_U_37130C2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_U_37130C ASSIGNING <U_37130C>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<U_37130C>-MANDT = 1.
<U_37130C>-PLVAR = 1.
<U_37130C>-OTYPE = 1.
<U_37130C>-OBJID = 1.
<U_37130C>-SUBTY = 1.
ENDLOOP.

LOOP AT IT_U_37130C INTO WA_U_37130C.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_U_37130C-ISTAT, sy-vline,
WA_U_37130C-BEGDA, sy-vline,
WA_U_37130C-ENDDA, sy-vline,
WA_U_37130C-VARYF, sy-vline,
WA_U_37130C-SEQNR, sy-vline,
WA_U_37130C-INFTY, sy-vline.
ENDLOOP. *Add any further fields from structure WA_U_37130C you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_U_37130C TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_U_37130C INTO WA_U_37130C. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit CUNIT, internal->external for field MAXBZGME CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_U_37130C-MAXBZGME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_U_37130C-MAXBZGME.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MINBZGME CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_U_37130C-MINBZGME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_U_37130C-MINBZGME.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field OPTBZGME CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_U_37130C-OPTBZGME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_U_37130C-OPTBZGME.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field DEALBZGME CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_U_37130C-DEALBZGME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_U_37130C-DEALBZGME.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_U_37130C_STR,
MANDT TYPE STRING,
PLVAR TYPE STRING,
OTYPE TYPE STRING,
OBJID TYPE STRING,
SUBTY TYPE STRING,
ISTAT TYPE STRING,
BEGDA TYPE STRING,
ENDDA TYPE STRING,
VARYF TYPE STRING,
SEQNR TYPE STRING,
INFTY TYPE STRING,
OTJID TYPE STRING,
AEDTM TYPE STRING,
UNAME TYPE STRING,
REASN TYPE STRING,
HISTO TYPE STRING,
ITXNR TYPE STRING,
LDURMAX TYPE STRING,
MAXBZGME TYPE STRING,
LDURMIN TYPE STRING,
MINBZGME TYPE STRING,
LDUROPT TYPE STRING,
OPTBZGME TYPE STRING,
DEALMAX TYPE STRING,
DEALBZGME TYPE STRING,
DEALEND TYPE STRING,
EBORULES TYPE STRING,
EBOSUCCS TYPE STRING,
LORULES TYPE STRING,
LOSUCCS TYPE STRING,END OF T_EKKO_STR. DATA: WA_U_37130C_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_U_37130C_STR-MANDT sy-vline
WA_U_37130C_STR-PLVAR sy-vline
WA_U_37130C_STR-OTYPE sy-vline
WA_U_37130C_STR-OBJID sy-vline
WA_U_37130C_STR-SUBTY sy-vline
WA_U_37130C_STR-ISTAT sy-vline
WA_U_37130C_STR-BEGDA sy-vline
WA_U_37130C_STR-ENDDA sy-vline
WA_U_37130C_STR-VARYF sy-vline
WA_U_37130C_STR-SEQNR sy-vline
WA_U_37130C_STR-INFTY sy-vline
WA_U_37130C_STR-OTJID sy-vline
WA_U_37130C_STR-AEDTM sy-vline
WA_U_37130C_STR-UNAME sy-vline
WA_U_37130C_STR-REASN sy-vline
WA_U_37130C_STR-HISTO sy-vline
WA_U_37130C_STR-ITXNR sy-vline
WA_U_37130C_STR-LDURMAX sy-vline
WA_U_37130C_STR-MAXBZGME sy-vline
WA_U_37130C_STR-LDURMIN sy-vline
WA_U_37130C_STR-MINBZGME sy-vline
WA_U_37130C_STR-LDUROPT sy-vline
WA_U_37130C_STR-OPTBZGME sy-vline
WA_U_37130C_STR-DEALMAX sy-vline
WA_U_37130C_STR-DEALBZGME sy-vline
WA_U_37130C_STR-DEALEND sy-vline
WA_U_37130C_STR-EBORULES sy-vline
WA_U_37130C_STR-EBOSUCCS sy-vline
WA_U_37130C_STR-LORULES sy-vline
WA_U_37130C_STR-LOSUCCS sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.