ABAP Select data from SAP table U_37100C into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP U_37100C table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to U_37100C. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the U_37100C table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_U_37100C TYPE STANDARD TABLE OF U_37100C,
      WA_U_37100C TYPE U_37100C,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <U_37100C> TYPE U_37100C.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_U_37100C.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM U_37100C
  INTO TABLE IT_U_37100C.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM U_37100C
*  INTO TABLE @DATA(IT_U_37100C2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_U_37100C INDEX 1 INTO DATA(WA_U_37100C2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_U_37100C ASSIGNING <U_37100C>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<U_37100C>-MANDT = 1.
<U_37100C>-PLVAR = 1.
<U_37100C>-OTYPE = 1.
<U_37100C>-OBJID = 1.
<U_37100C>-REPAIR = 1.
ENDLOOP.

LOOP AT IT_U_37100C INTO WA_U_37100C.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_U_37100C-SHORT, sy-vline,
WA_U_37100C-STEXT, sy-vline,
WA_U_37100C-GDATE, sy-vline,
WA_U_37100C-MC_SHORT, sy-vline,
WA_U_37100C-MC_STEXT, sy-vline,
WA_U_37100C-MC_SEARK, sy-vline.
ENDLOOP. *Add any further fields from structure WA_U_37100C you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_U_37100C TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_U_37100C INTO WA_U_37100C. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ISOLA, internal->external for field LANGU CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_U_37100C-LANGU IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_U_37100C-LANGU.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_U_37100C_STR,
MANDT TYPE STRING,
PLVAR TYPE STRING,
OTYPE TYPE STRING,
OBJID TYPE STRING,
REPAIR TYPE STRING,
SHORT TYPE STRING,
STEXT TYPE STRING,
GDATE TYPE STRING,
MC_SHORT TYPE STRING,
MC_STEXT TYPE STRING,
MC_SEARK TYPE STRING,
LANGU TYPE STRING,
TABNR TYPE STRING,
TABSEQNR TYPE STRING,
TLINE TYPE STRING,
TFORMAT TYPE STRING,
ISTAT TYPE STRING,
BEGDA TYPE STRING,
ENDDA TYPE STRING,
VARYF TYPE STRING,
SEQNR TYPE STRING,
INFTY TYPE STRING,
OTJID TYPE STRING,
AEDTM TYPE STRING,
UNAME TYPE STRING,
REASN TYPE STRING,
HISTO TYPE STRING,
ITXNR TYPE STRING,
RTEXT TYPE STRING,
INKBR TYPE STRING,
KONGX TYPE STRING,
NO_INT_INST TYPE STRING,
NO_INT_PART TYPE STRING,
DAYS_OFF_INST TYPE STRING,
DAYS_OFF_PART TYPE STRING,
MINPRESENCE TYPE STRING,
NYEARS TYPE STRING,
NMONTHS TYPE STRING,
N_TYPE TYPE STRING,
TEILN_TYP TYPE STRING,
BCHECK TYPE STRING,
VCHECK TYPE STRING,
KCHECK TYPE STRING,
QCHECK TYPE STRING,
QASSIGN TYPE STRING,
DELRKURS TYPE STRING,
INSRKTYP TYPE STRING,
XDATA TYPE STRING,END OF T_EKKO_STR. DATA: WA_U_37100C_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_U_37100C_STR-MANDT sy-vline
WA_U_37100C_STR-PLVAR sy-vline
WA_U_37100C_STR-OTYPE sy-vline
WA_U_37100C_STR-OBJID sy-vline
WA_U_37100C_STR-REPAIR sy-vline
WA_U_37100C_STR-SHORT sy-vline
WA_U_37100C_STR-STEXT sy-vline
WA_U_37100C_STR-GDATE sy-vline
WA_U_37100C_STR-MC_SHORT sy-vline
WA_U_37100C_STR-MC_STEXT sy-vline
WA_U_37100C_STR-MC_SEARK sy-vline
WA_U_37100C_STR-LANGU sy-vline
WA_U_37100C_STR-TABNR sy-vline
WA_U_37100C_STR-TABSEQNR sy-vline
WA_U_37100C_STR-TLINE sy-vline
WA_U_37100C_STR-TFORMAT sy-vline
WA_U_37100C_STR-ISTAT sy-vline
WA_U_37100C_STR-BEGDA sy-vline
WA_U_37100C_STR-ENDDA sy-vline
WA_U_37100C_STR-VARYF sy-vline
WA_U_37100C_STR-SEQNR sy-vline
WA_U_37100C_STR-INFTY sy-vline
WA_U_37100C_STR-OTJID sy-vline
WA_U_37100C_STR-AEDTM sy-vline
WA_U_37100C_STR-UNAME sy-vline
WA_U_37100C_STR-REASN sy-vline
WA_U_37100C_STR-HISTO sy-vline
WA_U_37100C_STR-ITXNR sy-vline
WA_U_37100C_STR-RTEXT sy-vline
WA_U_37100C_STR-INKBR sy-vline
WA_U_37100C_STR-KONGX sy-vline
WA_U_37100C_STR-NO_INT_INST sy-vline
WA_U_37100C_STR-NO_INT_PART sy-vline
WA_U_37100C_STR-DAYS_OFF_INST sy-vline
WA_U_37100C_STR-DAYS_OFF_PART sy-vline
WA_U_37100C_STR-MINPRESENCE sy-vline
WA_U_37100C_STR-NYEARS sy-vline
WA_U_37100C_STR-NMONTHS sy-vline
WA_U_37100C_STR-N_TYPE sy-vline
WA_U_37100C_STR-TEILN_TYP sy-vline
WA_U_37100C_STR-BCHECK sy-vline
WA_U_37100C_STR-VCHECK sy-vline
WA_U_37100C_STR-KCHECK sy-vline
WA_U_37100C_STR-QCHECK sy-vline
WA_U_37100C_STR-QASSIGN sy-vline
WA_U_37100C_STR-DELRKURS sy-vline
WA_U_37100C_STR-INSRKTYP sy-vline
WA_U_37100C_STR-XDATA sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.