ABAP Select data from SAP table U_26110 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP U_26110 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to U_26110. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the U_26110 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_U_26110 TYPE STANDARD TABLE OF U_26110,
      WA_U_26110 TYPE U_26110,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <U_26110> TYPE U_26110.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_U_26110.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM U_26110
  INTO TABLE IT_U_26110.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM U_26110
*  INTO TABLE @DATA(IT_U_261102).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_U_26110 INDEX 1 INTO DATA(WA_U_261102).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_U_26110 ASSIGNING <U_26110>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<U_26110>-MANDT = 1.
<U_26110>-UBLNR = 1.
<U_26110>-UBJAHR = 1.
<U_26110>-BUDAT = 1.
<U_26110>-ERDAT = 1.
ENDLOOP.

LOOP AT IT_U_26110 INTO WA_U_26110.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_U_26110-ERNAM, sy-vline,
WA_U_26110-AEDAT, sy-vline,
WA_U_26110-AENAM, sy-vline,
WA_U_26110-UBSTA, sy-vline,
WA_U_26110-BELNR, sy-vline,
ENDLOOP. *Add any further fields from structure WA_U_26110 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_U_26110 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_U_26110 INTO WA_U_26110. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field UBLNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_U_26110-UBLNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_U_26110-UBLNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field UBJAHR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_U_26110-UBJAHR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_U_26110-UBJAHR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field BELNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_U_26110-BELNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_U_26110-BELNR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_U_26110_STR,
MANDT TYPE STRING,
UBLNR TYPE STRING,
UBJAHR TYPE STRING,
BUDAT TYPE STRING,
ERDAT TYPE STRING,
ERNAM TYPE STRING,
AEDAT TYPE STRING,
AENAM TYPE STRING,
UBSTA TYPE STRING,
BELNR TYPE STRING,END OF T_EKKO_STR. DATA: WA_U_26110_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_U_26110_STR-MANDT sy-vline
WA_U_26110_STR-UBLNR sy-vline
WA_U_26110_STR-UBJAHR sy-vline
WA_U_26110_STR-BUDAT sy-vline
WA_U_26110_STR-ERDAT sy-vline
WA_U_26110_STR-ERNAM sy-vline
WA_U_26110_STR-AEDAT sy-vline
WA_U_26110_STR-AENAM sy-vline
WA_U_26110_STR-UBSTA sy-vline
WA_U_26110_STR-BELNR sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.