ABAP Select data from SAP table U_25677 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP U_25677 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to U_25677. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the U_25677 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_U_25677 TYPE STANDARD TABLE OF U_25677,
      WA_U_25677 TYPE U_25677,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <U_25677> TYPE U_25677.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_U_25677.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM U_25677
  INTO TABLE IT_U_25677.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM U_25677
*  INTO TABLE @DATA(IT_U_256772).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_U_25677 INDEX 1 INTO DATA(WA_U_256772).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_U_25677 ASSIGNING <U_25677>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<U_25677>-MLST_MANDT = 1.
<U_25677>-AUTYP = 1.
<U_25677>-MLST_SMLNR = 1.
<U_25677>-MLSET = 1.
<U_25677>-MLSTN = 1.
ENDLOOP.

LOOP AT IT_U_25677 INTO WA_U_25677.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_U_25677-USERH, sy-vline,
WA_U_25677-DATEH, sy-vline,
WA_U_25677-USERV, sy-vline,
WA_U_25677-DATEV, sy-vline,
WA_U_25677-LST_FERTG, sy-vline,
WA_U_25677-LATED, sy-vline.
ENDLOOP. *Add any further fields from structure WA_U_25677 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_U_25677 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_U_25677 INTO WA_U_25677. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit CUNIT, internal->external for field DELTE CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_U_25677-DELTE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_U_25677-DELTE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ISOLA, internal->external for field LANGU CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_U_25677-LANGU IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_U_25677-LANGU.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ISOLA, internal->external for field LTXSP CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_U_25677-LTXSP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_U_25677-LTXSP.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_U_25677_STR,
MLST_MANDT TYPE STRING,
AUTYP TYPE STRING,
MLST_SMLNR TYPE STRING,
MLSET TYPE STRING,
MLSTN TYPE STRING,
USERH TYPE STRING,
DATEH TYPE STRING,
USERV TYPE STRING,
DATEV TYPE STRING,
LST_FERTG TYPE STRING,
LATED TYPE STRING,
DLTAS TYPE STRING,
DELTA TYPE STRING,
DELTE TYPE STRING,
PRCNT TYPE STRING,
SDDAT TYPE STRING,
KZ_LSTWR TYPE STRING,
KZ_WFLOW TYPE STRING,
KZ_FAKTP TYPE STRING,
KZ_FRMST TYPE STRING,
RELSU TYPE STRING,
RELMS TYPE STRING,
INCPN TYPE STRING,
INCNW TYPE STRING,
INCSN TYPE STRING,
WKFLW TYPE STRING,
RELSU_SS TYPE STRING,
RELMS_SS TYPE STRING,
INCPN_SS TYPE STRING,
INCNW_SS TYPE STRING,
INCSN_SS TYPE STRING,
WKFLW_SS TYPE STRING,
RELSU_SM TYPE STRING,
RELMS_SM TYPE STRING,
INCPN_SM TYPE STRING,
INCNW_SM TYPE STRING,
INCSN_SM TYPE STRING,
WKFLW_SM TYPE STRING,
RELSU_CH TYPE STRING,
RELMS_CH TYPE STRING,
INCPN_CH TYPE STRING,
INCNW_CH TYPE STRING,
INCSN_CH TYPE STRING,
WKFLW_CH TYPE STRING,
RELSU_SG TYPE STRING,
RELMS_SG TYPE STRING,
INCPN_SG TYPE STRING,
INCNW_SG TYPE STRING,
INCSN_SG TYPE STRING,
WKFLW_SG TYPE STRING,
RELSU_TR TYPE STRING,
RELMS_TR TYPE STRING,
INCPN_TR TYPE STRING,
INCNW_TR TYPE STRING,
INCSN_TR TYPE STRING,
WKFLW_TR TYPE STRING,
RELSU_US TYPE STRING,
RELMS_US TYPE STRING,
INCPN_US TYPE STRING,
INCNW_US TYPE STRING,
INCSN_US TYPE STRING,
WKFLW_US TYPE STRING,
LANGU TYPE STRING,
KTEXT TYPE STRING,
LTXSP TYPE STRING,END OF T_EKKO_STR. DATA: WA_U_25677_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_U_25677_STR-MLST_MANDT sy-vline
WA_U_25677_STR-AUTYP sy-vline
WA_U_25677_STR-MLST_SMLNR sy-vline
WA_U_25677_STR-MLSET sy-vline
WA_U_25677_STR-MLSTN sy-vline
WA_U_25677_STR-USERH sy-vline
WA_U_25677_STR-DATEH sy-vline
WA_U_25677_STR-USERV sy-vline
WA_U_25677_STR-DATEV sy-vline
WA_U_25677_STR-LST_FERTG sy-vline
WA_U_25677_STR-LATED sy-vline
WA_U_25677_STR-DLTAS sy-vline
WA_U_25677_STR-DELTA sy-vline
WA_U_25677_STR-DELTE sy-vline
WA_U_25677_STR-PRCNT sy-vline
WA_U_25677_STR-SDDAT sy-vline
WA_U_25677_STR-KZ_LSTWR sy-vline
WA_U_25677_STR-KZ_WFLOW sy-vline
WA_U_25677_STR-KZ_FAKTP sy-vline
WA_U_25677_STR-KZ_FRMST sy-vline
WA_U_25677_STR-RELSU sy-vline
WA_U_25677_STR-RELMS sy-vline
WA_U_25677_STR-INCPN sy-vline
WA_U_25677_STR-INCNW sy-vline
WA_U_25677_STR-INCSN sy-vline
WA_U_25677_STR-WKFLW sy-vline
WA_U_25677_STR-RELSU_SS sy-vline
WA_U_25677_STR-RELMS_SS sy-vline
WA_U_25677_STR-INCPN_SS sy-vline
WA_U_25677_STR-INCNW_SS sy-vline
WA_U_25677_STR-INCSN_SS sy-vline
WA_U_25677_STR-WKFLW_SS sy-vline
WA_U_25677_STR-RELSU_SM sy-vline
WA_U_25677_STR-RELMS_SM sy-vline
WA_U_25677_STR-INCPN_SM sy-vline
WA_U_25677_STR-INCNW_SM sy-vline
WA_U_25677_STR-INCSN_SM sy-vline
WA_U_25677_STR-WKFLW_SM sy-vline
WA_U_25677_STR-RELSU_CH sy-vline
WA_U_25677_STR-RELMS_CH sy-vline
WA_U_25677_STR-INCPN_CH sy-vline
WA_U_25677_STR-INCNW_CH sy-vline
WA_U_25677_STR-INCSN_CH sy-vline
WA_U_25677_STR-WKFLW_CH sy-vline
WA_U_25677_STR-RELSU_SG sy-vline
WA_U_25677_STR-RELMS_SG sy-vline
WA_U_25677_STR-INCPN_SG sy-vline
WA_U_25677_STR-INCNW_SG sy-vline
WA_U_25677_STR-INCSN_SG sy-vline
WA_U_25677_STR-WKFLW_SG sy-vline
WA_U_25677_STR-RELSU_TR sy-vline
WA_U_25677_STR-RELMS_TR sy-vline
WA_U_25677_STR-INCPN_TR sy-vline
WA_U_25677_STR-INCNW_TR sy-vline
WA_U_25677_STR-INCSN_TR sy-vline
WA_U_25677_STR-WKFLW_TR sy-vline
WA_U_25677_STR-RELSU_US sy-vline
WA_U_25677_STR-RELMS_US sy-vline
WA_U_25677_STR-INCPN_US sy-vline
WA_U_25677_STR-INCNW_US sy-vline
WA_U_25677_STR-INCSN_US sy-vline
WA_U_25677_STR-WKFLW_US sy-vline
WA_U_25677_STR-LANGU sy-vline
WA_U_25677_STR-KTEXT sy-vline
WA_U_25677_STR-LTXSP sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.