ABAP Select data from SAP table U_25600 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP U_25600 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to U_25600. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the U_25600 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_U_25600 TYPE STANDARD TABLE OF U_25600,
      WA_U_25600 TYPE U_25600,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <U_25600> TYPE U_25600.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_U_25600.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM U_25600
  INTO TABLE IT_U_25600.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM U_25600
*  INTO TABLE @DATA(IT_U_256002).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_U_25600 INDEX 1 INTO DATA(WA_U_256002).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_U_25600 ASSIGNING <U_25600>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<U_25600>-MANDT = 1.
<U_25600>-QMART = 1.
<U_25600>-SPRAS = 1.
<U_25600>-QMTYP = 1.
<U_25600>-RBNR = 1.
ENDLOOP.

LOOP AT IT_U_25600 INTO WA_U_25600.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_U_25600-HERKZ, sy-vline,
WA_U_25600-BEZZT, sy-vline,
WA_U_25600-QMNUK, sy-vline,
WA_U_25600-HSCRTP, sy-vline,
WA_U_25600-OSCRTP, sy-vline,
WA_U_25600-PSCRTP, sy-vline.
ENDLOOP. *Add any further fields from structure WA_U_25600 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_U_25600 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_U_25600 INTO WA_U_25600. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ISOLA, internal->external for field SPRAS CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_U_25600-SPRAS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_U_25600-SPRAS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AUART, internal->external for field SDAUART CALL FUNCTION 'CONVERSION_EXIT_AUART_OUTPUT' EXPORTING input = WA_U_25600-SDAUART IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_U_25600-SDAUART.
WRITE:/ 'New Value:', ld_input.

*Conversion exit PARVW, internal->external for field PARVW_KUND CALL FUNCTION 'CONVERSION_EXIT_PARVW_OUTPUT' EXPORTING input = WA_U_25600-PARVW_KUND IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_U_25600-PARVW_KUND.
WRITE:/ 'New Value:', ld_input.

*Conversion exit PARVW, internal->external for field PARVW_AP CALL FUNCTION 'CONVERSION_EXIT_PARVW_OUTPUT' EXPORTING input = WA_U_25600-PARVW_AP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_U_25600-PARVW_AP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit PARVW, internal->external for field PARVW_INT CALL FUNCTION 'CONVERSION_EXIT_PARVW_OUTPUT' EXPORTING input = WA_U_25600-PARVW_INT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_U_25600-PARVW_INT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit PARVW, internal->external for field PARVW_LIEF CALL FUNCTION 'CONVERSION_EXIT_PARVW_OUTPUT' EXPORTING input = WA_U_25600-PARVW_LIEF IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_U_25600-PARVW_LIEF.
WRITE:/ 'New Value:', ld_input.

*Conversion exit PARVW, internal->external for field PARVW_VERA CALL FUNCTION 'CONVERSION_EXIT_PARVW_OUTPUT' EXPORTING input = WA_U_25600-PARVW_VERA IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_U_25600-PARVW_VERA.
WRITE:/ 'New Value:', ld_input.

*Conversion exit PARVW, internal->external for field PARVW_AUTO CALL FUNCTION 'CONVERSION_EXIT_PARVW_OUTPUT' EXPORTING input = WA_U_25600-PARVW_AUTO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_U_25600-PARVW_AUTO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit PARVW, internal->external for field PARVW_QMSM CALL FUNCTION 'CONVERSION_EXIT_PARVW_OUTPUT' EXPORTING input = WA_U_25600-PARVW_QMSM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_U_25600-PARVW_QMSM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field STAFO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_U_25600-STAFO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_U_25600-STAFO.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_U_25600_STR,
MANDT TYPE STRING,
QMART TYPE STRING,
SPRAS TYPE STRING,
QMTYP TYPE STRING,
RBNR TYPE STRING,
HERKZ TYPE STRING,
BEZZT TYPE STRING,
QMNUK TYPE STRING,
HSCRTP TYPE STRING,
OSCRTP TYPE STRING,
PSCRTP TYPE STRING,
PARGR TYPE STRING,
STSMA TYPE STRING,
SMSTSMA TYPE STRING,
ARTPR TYPE STRING,
SDAUART TYPE STRING,
COAUART TYPE STRING,
PARVW_KUND TYPE STRING,
PARVW_AP TYPE STRING,
PARVW_INT TYPE STRING,
PARVW_LIEF TYPE STRING,
PARVW_VERA TYPE STRING,
PARVW_AUTO TYPE STRING,
PARVW_QMSM TYPE STRING,
KLAKT TYPE STRING,
INFO_WIND TYPE STRING,
SERWI TYPE STRING,
ESCAL TYPE STRING,
FEKAT TYPE STRING,
URKAT TYPE STRING,
MAKAT TYPE STRING,
MFKAT TYPE STRING,
OTKAT TYPE STRING,
SAKAT TYPE STRING,
STAFO TYPE STRING,
QMWAERS TYPE STRING,
QMWERT TYPE STRING,
FBS_CREATE TYPE STRING,
FBS_DYNNR TYPE STRING,
TDFORMAT TYPE STRING,
KZEILE TYPE STRING,
USERSCR1 TYPE STRING,
USERSCR2 TYPE STRING,
QMLTXT01 TYPE STRING,
QMLTXT02 TYPE STRING,
EARLY_NUM TYPE STRING,
AUTOM_CONT TYPE STRING,
QMARTX TYPE STRING,
AUART TYPE STRING,
AUART2 TYPE STRING,END OF T_EKKO_STR. DATA: WA_U_25600_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_U_25600_STR-MANDT sy-vline
WA_U_25600_STR-QMART sy-vline
WA_U_25600_STR-SPRAS sy-vline
WA_U_25600_STR-QMTYP sy-vline
WA_U_25600_STR-RBNR sy-vline
WA_U_25600_STR-HERKZ sy-vline
WA_U_25600_STR-BEZZT sy-vline
WA_U_25600_STR-QMNUK sy-vline
WA_U_25600_STR-HSCRTP sy-vline
WA_U_25600_STR-OSCRTP sy-vline
WA_U_25600_STR-PSCRTP sy-vline
WA_U_25600_STR-PARGR sy-vline
WA_U_25600_STR-STSMA sy-vline
WA_U_25600_STR-SMSTSMA sy-vline
WA_U_25600_STR-ARTPR sy-vline
WA_U_25600_STR-SDAUART sy-vline
WA_U_25600_STR-COAUART sy-vline
WA_U_25600_STR-PARVW_KUND sy-vline
WA_U_25600_STR-PARVW_AP sy-vline
WA_U_25600_STR-PARVW_INT sy-vline
WA_U_25600_STR-PARVW_LIEF sy-vline
WA_U_25600_STR-PARVW_VERA sy-vline
WA_U_25600_STR-PARVW_AUTO sy-vline
WA_U_25600_STR-PARVW_QMSM sy-vline
WA_U_25600_STR-KLAKT sy-vline
WA_U_25600_STR-INFO_WIND sy-vline
WA_U_25600_STR-SERWI sy-vline
WA_U_25600_STR-ESCAL sy-vline
WA_U_25600_STR-FEKAT sy-vline
WA_U_25600_STR-URKAT sy-vline
WA_U_25600_STR-MAKAT sy-vline
WA_U_25600_STR-MFKAT sy-vline
WA_U_25600_STR-OTKAT sy-vline
WA_U_25600_STR-SAKAT sy-vline
WA_U_25600_STR-STAFO sy-vline
WA_U_25600_STR-QMWAERS sy-vline
WA_U_25600_STR-QMWERT sy-vline
WA_U_25600_STR-FBS_CREATE sy-vline
WA_U_25600_STR-FBS_DYNNR sy-vline
WA_U_25600_STR-TDFORMAT sy-vline
WA_U_25600_STR-KZEILE sy-vline
WA_U_25600_STR-USERSCR1 sy-vline
WA_U_25600_STR-USERSCR2 sy-vline
WA_U_25600_STR-QMLTXT01 sy-vline
WA_U_25600_STR-QMLTXT02 sy-vline
WA_U_25600_STR-EARLY_NUM sy-vline
WA_U_25600_STR-AUTOM_CONT sy-vline
WA_U_25600_STR-QMARTX sy-vline
WA_U_25600_STR-AUART sy-vline
WA_U_25600_STR-AUART2 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.