ABAP Select data from SAP table U_24135 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP U_24135 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to U_24135. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the U_24135 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_U_24135 TYPE STANDARD TABLE OF U_24135,
      WA_U_24135 TYPE U_24135,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <U_24135> TYPE U_24135.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_U_24135.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM U_24135
  INTO TABLE IT_U_24135.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM U_24135
*  INTO TABLE @DATA(IT_U_241352).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_U_24135 INDEX 1 INTO DATA(WA_U_241352).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_U_24135 ASSIGNING <U_24135>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<U_24135>-MANDT = 1.
<U_24135>-APPLCLASS = 1.
<U_24135>-SUBCLASS = 1.
<U_24135>-TABNAME = 1.
<U_24135>-REPID = 1.
ENDLOOP.

LOOP AT IT_U_24135 INTO WA_U_24135.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_U_24135-TFLAG, sy-vline,
WA_U_24135-SMODE, sy-vline,
WA_U_24135-SOURC, sy-vline,
WA_U_24135-UNAME, sy-vline,
WA_U_24135-GDATE, sy-vline,
WA_U_24135-MODCN, sy-vline.
ENDLOOP. *Add any further fields from structure WA_U_24135 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_U_24135 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_U_24135 INTO WA_U_24135. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_U_24135_STR,
MANDT TYPE STRING,
APPLCLASS TYPE STRING,
SUBCLASS TYPE STRING,
TABNAME TYPE STRING,
REPID TYPE STRING,
TFLAG TYPE STRING,
SMODE TYPE STRING,
SOURC TYPE STRING,
UNAME TYPE STRING,
GDATE TYPE STRING,
MODCN TYPE STRING,
MODNA TYPE STRING,
MODDA TYPE STRING,
MODTI TYPE STRING,
CNSUB TYPE STRING,
LASUB TYPE STRING,
SECU TYPE STRING,
INDX TYPE STRING,
INDXDA TYPE STRING,
INDXTI TYPE STRING,
DVERS TYPE STRING,
EPOS TYPE STRING,
SUBCLASSF TYPE STRING,
FORM TYPE STRING,
RNAME TYPE STRING,
VARKE TYPE STRING,
VARFE TYPE STRING,
VARTE TYPE STRING,
PAGEW TYPE STRING,END OF T_EKKO_STR. DATA: WA_U_24135_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_U_24135_STR-MANDT sy-vline
WA_U_24135_STR-APPLCLASS sy-vline
WA_U_24135_STR-SUBCLASS sy-vline
WA_U_24135_STR-TABNAME sy-vline
WA_U_24135_STR-REPID sy-vline
WA_U_24135_STR-TFLAG sy-vline
WA_U_24135_STR-SMODE sy-vline
WA_U_24135_STR-SOURC sy-vline
WA_U_24135_STR-UNAME sy-vline
WA_U_24135_STR-GDATE sy-vline
WA_U_24135_STR-MODCN sy-vline
WA_U_24135_STR-MODNA sy-vline
WA_U_24135_STR-MODDA sy-vline
WA_U_24135_STR-MODTI sy-vline
WA_U_24135_STR-CNSUB sy-vline
WA_U_24135_STR-LASUB sy-vline
WA_U_24135_STR-SECU sy-vline
WA_U_24135_STR-INDX sy-vline
WA_U_24135_STR-INDXDA sy-vline
WA_U_24135_STR-INDXTI sy-vline
WA_U_24135_STR-DVERS sy-vline
WA_U_24135_STR-EPOS sy-vline
WA_U_24135_STR-SUBCLASSF sy-vline
WA_U_24135_STR-FORM sy-vline
WA_U_24135_STR-RNAME sy-vline
WA_U_24135_STR-VARKE sy-vline
WA_U_24135_STR-VARFE sy-vline
WA_U_24135_STR-VARTE sy-vline
WA_U_24135_STR-PAGEW sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.