ABAP Select data from SAP table U_24112 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP U_24112 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to U_24112. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the U_24112 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_U_24112 TYPE STANDARD TABLE OF U_24112,
      WA_U_24112 TYPE U_24112,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <U_24112> TYPE U_24112.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_U_24112.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM U_24112
  INTO TABLE IT_U_24112.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM U_24112
*  INTO TABLE @DATA(IT_U_241122).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_U_24112 INDEX 1 INTO DATA(WA_U_241122).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_U_24112 ASSIGNING <U_24112>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<U_24112>-LANGU = 1.
<U_24112>-APPLC = 1.
<U_24112>-KEYRA = 1.
<U_24112>-TXT_M = 1.
<U_24112>-TXT_S = 1.
ENDLOOP.

LOOP AT IT_U_24112 INTO WA_U_24112.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_U_24112-ROLNM, sy-vline,
WA_U_24112-SBGRP, sy-vline,
WA_U_24112-AGGDI, sy-vline,
WA_U_24112-AGGTM, sy-vline,
WA_U_24112-AGGFI, sy-vline,
WA_U_24112-OPORD, sy-vline.
ENDLOOP. *Add any further fields from structure WA_U_24112 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_U_24112 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_U_24112 INTO WA_U_24112. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ISOLA, internal->external for field LANGU CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_U_24112-LANGU IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_U_24112-LANGU.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_U_24112_STR,
LANGU TYPE STRING,
APPLC TYPE STRING,
KEYRA TYPE STRING,
TXT_M TYPE STRING,
TXT_S TYPE STRING,
ROLNM TYPE STRING,
SBGRP TYPE STRING,
AGGDI TYPE STRING,
AGGTM TYPE STRING,
AGGFI TYPE STRING,
OPORD TYPE STRING,
PRDEC TYPE STRING,
PRSNT TYPE STRING,
CCNUM TYPE STRING,
DCURR TYPE STRING,
CHNAM TYPE STRING,
CHDAT TYPE STRING,
CHTIM TYPE STRING,
TFLAG TYPE STRING,
RCSIN TYPE STRING,
RSLIN TYPE STRING,END OF T_EKKO_STR. DATA: WA_U_24112_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_U_24112_STR-LANGU sy-vline
WA_U_24112_STR-APPLC sy-vline
WA_U_24112_STR-KEYRA sy-vline
WA_U_24112_STR-TXT_M sy-vline
WA_U_24112_STR-TXT_S sy-vline
WA_U_24112_STR-ROLNM sy-vline
WA_U_24112_STR-SBGRP sy-vline
WA_U_24112_STR-AGGDI sy-vline
WA_U_24112_STR-AGGTM sy-vline
WA_U_24112_STR-AGGFI sy-vline
WA_U_24112_STR-OPORD sy-vline
WA_U_24112_STR-PRDEC sy-vline
WA_U_24112_STR-PRSNT sy-vline
WA_U_24112_STR-CCNUM sy-vline
WA_U_24112_STR-DCURR sy-vline
WA_U_24112_STR-CHNAM sy-vline
WA_U_24112_STR-CHDAT sy-vline
WA_U_24112_STR-CHTIM sy-vline
WA_U_24112_STR-TFLAG sy-vline
WA_U_24112_STR-RCSIN sy-vline
WA_U_24112_STR-RSLIN sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.