ABAP Select data from SAP table U_24110 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP U_24110 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to U_24110. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the U_24110 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_U_24110 TYPE STANDARD TABLE OF U_24110,
      WA_U_24110 TYPE U_24110,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <U_24110> TYPE U_24110.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_U_24110.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM U_24110
  INTO TABLE IT_U_24110.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM U_24110
*  INTO TABLE @DATA(IT_U_241102).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_U_24110 INDEX 1 INTO DATA(WA_U_241102).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_U_24110 ASSIGNING <U_24110>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<U_24110>-MANDT = 1.
<U_24110>-HIEID = 1.
<U_24110>-LFDID = 1.
<U_24110>-CLTYP = 1.
<U_24110>-POIUP = 1.
ENDLOOP.

LOOP AT IT_U_24110 INTO WA_U_24110.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_U_24110-POIDO, sy-vline,
WA_U_24110-POINE, sy-vline,
WA_U_24110-POIPR, sy-vline,
ENDLOOP. *Add any further fields from structure WA_U_24110 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_U_24110 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_U_24110 INTO WA_U_24110. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_U_24110_STR,
MANDT TYPE STRING,
HIEID TYPE STRING,
LFDID TYPE STRING,
CLTYP TYPE STRING,
POIUP TYPE STRING,
POIDO TYPE STRING,
POINE TYPE STRING,
POIPR TYPE STRING,END OF T_EKKO_STR. DATA: WA_U_24110_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_U_24110_STR-MANDT sy-vline
WA_U_24110_STR-HIEID sy-vline
WA_U_24110_STR-LFDID sy-vline
WA_U_24110_STR-CLTYP sy-vline
WA_U_24110_STR-POIUP sy-vline
WA_U_24110_STR-POIDO sy-vline
WA_U_24110_STR-POINE sy-vline
WA_U_24110_STR-POIPR sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.