ABAP Select data from SAP table U_24106 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP U_24106 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to U_24106. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the U_24106 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_U_24106 TYPE STANDARD TABLE OF U_24106,
      WA_U_24106 TYPE U_24106,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <U_24106> TYPE U_24106.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_U_24106.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM U_24106
  INTO TABLE IT_U_24106.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM U_24106
*  INTO TABLE @DATA(IT_U_241062).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_U_24106 INDEX 1 INTO DATA(WA_U_241062).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_U_24106 ASSIGNING <U_24106>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<U_24106>-FIENM = 1.
<U_24106>-USGFL = 1.
<U_24106>-ROLNM = 1.
<U_24106>-TIMFL = 1.
<U_24106>-CHTAB = 1.
ENDLOOP.

LOOP AT IT_U_24106 INTO WA_U_24106.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_U_24106-CHFIE, sy-vline,
WA_U_24106-VALEX, sy-vline,
WA_U_24106-FIXVL, sy-vline,
WA_U_24106-TIMLC, sy-vline,
WA_U_24106-RETAB, sy-vline,
WA_U_24106-REFIE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_U_24106 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_U_24106 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_U_24106 INTO WA_U_24106. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit CUNIT, internal->external for field UNIT0 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_U_24106-UNIT0 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_U_24106-UNIT0.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_U_24106_STR,
FIENM TYPE STRING,
USGFL TYPE STRING,
ROLNM TYPE STRING,
TIMFL TYPE STRING,
CHTAB TYPE STRING,
CHFIE TYPE STRING,
VALEX TYPE STRING,
FIXVL TYPE STRING,
TIMLC TYPE STRING,
RETAB TYPE STRING,
REFIE TYPE STRING,
REFIL TYPE STRING,
REFLL TYPE STRING,
VIEWN TYPE STRING,
ORTAB TYPE STRING,
ORFIE TYPE STRING,
DIMPR TYPE STRING,
REPIN TYPE STRING,
PLAIN TYPE STRING,
LITIN TYPE STRING,
RCSIN TYPE STRING,
RSLIN TYPE STRING,
CHAIN TYPE STRING,
AGGDI TYPE STRING,
AGGTM TYPE STRING,
AGGFI TYPE STRING,
PRDEC TYPE STRING,
PRSNT TYPE STRING,
SBGRP TYPE STRING,
CCNUM TYPE STRING,
DCURR TYPE STRING,
RFTAB TYPE STRING,
RFFIE TYPE STRING,
CQMRK TYPE STRING,
CUKY0 TYPE STRING,
UNIT0 TYPE STRING,
CQFIE TYPE STRING,
TFLAG TYPE STRING,
DMAC TYPE STRING,
CHNAM TYPE STRING,
CHDAT TYPE STRING,
CHTIM TYPE STRING,END OF T_EKKO_STR. DATA: WA_U_24106_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_U_24106_STR-FIENM sy-vline
WA_U_24106_STR-USGFL sy-vline
WA_U_24106_STR-ROLNM sy-vline
WA_U_24106_STR-TIMFL sy-vline
WA_U_24106_STR-CHTAB sy-vline
WA_U_24106_STR-CHFIE sy-vline
WA_U_24106_STR-VALEX sy-vline
WA_U_24106_STR-FIXVL sy-vline
WA_U_24106_STR-TIMLC sy-vline
WA_U_24106_STR-RETAB sy-vline
WA_U_24106_STR-REFIE sy-vline
WA_U_24106_STR-REFIL sy-vline
WA_U_24106_STR-REFLL sy-vline
WA_U_24106_STR-VIEWN sy-vline
WA_U_24106_STR-ORTAB sy-vline
WA_U_24106_STR-ORFIE sy-vline
WA_U_24106_STR-DIMPR sy-vline
WA_U_24106_STR-REPIN sy-vline
WA_U_24106_STR-PLAIN sy-vline
WA_U_24106_STR-LITIN sy-vline
WA_U_24106_STR-RCSIN sy-vline
WA_U_24106_STR-RSLIN sy-vline
WA_U_24106_STR-CHAIN sy-vline
WA_U_24106_STR-AGGDI sy-vline
WA_U_24106_STR-AGGTM sy-vline
WA_U_24106_STR-AGGFI sy-vline
WA_U_24106_STR-PRDEC sy-vline
WA_U_24106_STR-PRSNT sy-vline
WA_U_24106_STR-SBGRP sy-vline
WA_U_24106_STR-CCNUM sy-vline
WA_U_24106_STR-DCURR sy-vline
WA_U_24106_STR-RFTAB sy-vline
WA_U_24106_STR-RFFIE sy-vline
WA_U_24106_STR-CQMRK sy-vline
WA_U_24106_STR-CUKY0 sy-vline
WA_U_24106_STR-UNIT0 sy-vline
WA_U_24106_STR-CQFIE sy-vline
WA_U_24106_STR-TFLAG sy-vline
WA_U_24106_STR-DMAC sy-vline
WA_U_24106_STR-CHNAM sy-vline
WA_U_24106_STR-CHDAT sy-vline
WA_U_24106_STR-CHTIM sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.