ABAP Select data from SAP table U_16827 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP U_16827 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to U_16827. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the U_16827 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_U_16827 TYPE STANDARD TABLE OF U_16827,
      WA_U_16827 TYPE U_16827,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <U_16827> TYPE U_16827.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_U_16827.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM U_16827
  INTO TABLE IT_U_16827.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM U_16827
*  INTO TABLE @DATA(IT_U_168272).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_U_16827 INDEX 1 INTO DATA(WA_U_168272).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_U_16827 ASSIGNING <U_16827>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<U_16827>-MANDT = 1.
<U_16827>-MATNR = 1.
<U_16827>-SPRAS = 1.
<U_16827>-MTART = 1.
<U_16827>-MBRSH = 1.
ENDLOOP.

LOOP AT IT_U_16827 INTO WA_U_16827.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_U_16827-MATKL, sy-vline,
WA_U_16827-MEINS, sy-vline,
WA_U_16827-LVORM, sy-vline,
WA_U_16827-LAEDA, sy-vline,
WA_U_16827-AENAM, sy-vline,
WA_U_16827-ERSDA, sy-vline.
ENDLOOP. *Add any further fields from structure WA_U_16827 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_U_16827 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_U_16827 INTO WA_U_16827. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_U_16827-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_U_16827-MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ISOLA, internal->external for field SPRAS CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_U_16827-SPRAS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_U_16827-SPRAS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MEINS CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_U_16827-MEINS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_U_16827-MEINS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MEABM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_U_16827-MEABM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_U_16827-MEABM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field GEWEI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_U_16827-GEWEI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_U_16827-GEWEI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field VOLEH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_U_16827-VOLEH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_U_16827-VOLEH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit EAN11, internal->external for field EAN11 CALL FUNCTION 'CONVERSION_EXIT_EAN11_OUTPUT' EXPORTING input = WA_U_16827-EAN11 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_U_16827-EAN11.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field WVRKM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_U_16827-WVRKM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_U_16827-WVRKM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field WAUSM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_U_16827-WAUSM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_U_16827-WAUSM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field WEXPM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_U_16827-WEXPM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_U_16827-WEXPM.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_U_16827_STR,
MANDT TYPE STRING,
MATNR TYPE STRING,
SPRAS TYPE STRING,
MTART TYPE STRING,
MBRSH TYPE STRING,
MATKL TYPE STRING,
MEINS TYPE STRING,
LVORM TYPE STRING,
LAEDA TYPE STRING,
AENAM TYPE STRING,
ERSDA TYPE STRING,
ERNAM TYPE STRING,
VPSTA TYPE STRING,
PSTAT TYPE STRING,
MAKTX TYPE STRING,
BREIT TYPE STRING,
HOEHE TYPE STRING,
LAENG TYPE STRING,
MEABM TYPE STRING,
BRGEW TYPE STRING,
GEWEI TYPE STRING,
VOLUM TYPE STRING,
VOLEH TYPE STRING,
NTGEW TYPE STRING,
BISMT TYPE STRING,
GROES TYPE STRING,
LABOR TYPE STRING,
SPART TYPE STRING,
EAN11 TYPE STRING,
NUMTP TYPE STRING,
PRDHA TYPE STRING,
BEGRU TYPE STRING,
EXTWG TYPE STRING,
MSTAE TYPE STRING,
MSTDE TYPE STRING,
KOSCH TYPE STRING,
MAKTG TYPE STRING,
BBTYP TYPE STRING,
SERVV TYPE STRING,
WMAAB TYPE STRING,
WEKGR TYPE STRING,
WVRKM TYPE STRING,
WAUSM TYPE STRING,
WHERL TYPE STRING,
WHERR TYPE STRING,
WLADG TYPE STRING,
SSTUF TYPE STRING,
PFLKS TYPE STRING,
LSTFL TYPE STRING,
LSTVZ TYPE STRING,
LSTAK TYPE STRING,
LDVFL TYPE STRING,
LDBFL TYPE STRING,
LDVZL TYPE STRING,
LDBZL TYPE STRING,
VDVFL TYPE STRING,
VDBFL TYPE STRING,
VDVZL TYPE STRING,
VDBZL TYPE STRING,
WBKLA TYPE STRING,
WSTAW TYPE STRING,
WPSTA TYPE STRING,
WBWSP TYPE STRING,
WEXPM TYPE STRING,
KWDHT TYPE STRING,
PRERF TYPE STRING,
RBZUL TYPE STRING,
SCAGR TYPE STRING,
BWVOR TYPE STRING,
BWSCL TYPE STRING,
PLGTP TYPE STRING,END OF T_EKKO_STR. DATA: WA_U_16827_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_U_16827_STR-MANDT sy-vline
WA_U_16827_STR-MATNR sy-vline
WA_U_16827_STR-SPRAS sy-vline
WA_U_16827_STR-MTART sy-vline
WA_U_16827_STR-MBRSH sy-vline
WA_U_16827_STR-MATKL sy-vline
WA_U_16827_STR-MEINS sy-vline
WA_U_16827_STR-LVORM sy-vline
WA_U_16827_STR-LAEDA sy-vline
WA_U_16827_STR-AENAM sy-vline
WA_U_16827_STR-ERSDA sy-vline
WA_U_16827_STR-ERNAM sy-vline
WA_U_16827_STR-VPSTA sy-vline
WA_U_16827_STR-PSTAT sy-vline
WA_U_16827_STR-MAKTX sy-vline
WA_U_16827_STR-BREIT sy-vline
WA_U_16827_STR-HOEHE sy-vline
WA_U_16827_STR-LAENG sy-vline
WA_U_16827_STR-MEABM sy-vline
WA_U_16827_STR-BRGEW sy-vline
WA_U_16827_STR-GEWEI sy-vline
WA_U_16827_STR-VOLUM sy-vline
WA_U_16827_STR-VOLEH sy-vline
WA_U_16827_STR-NTGEW sy-vline
WA_U_16827_STR-BISMT sy-vline
WA_U_16827_STR-GROES sy-vline
WA_U_16827_STR-LABOR sy-vline
WA_U_16827_STR-SPART sy-vline
WA_U_16827_STR-EAN11 sy-vline
WA_U_16827_STR-NUMTP sy-vline
WA_U_16827_STR-PRDHA sy-vline
WA_U_16827_STR-BEGRU sy-vline
WA_U_16827_STR-EXTWG sy-vline
WA_U_16827_STR-MSTAE sy-vline
WA_U_16827_STR-MSTDE sy-vline
WA_U_16827_STR-KOSCH sy-vline
WA_U_16827_STR-MAKTG sy-vline
WA_U_16827_STR-BBTYP sy-vline
WA_U_16827_STR-SERVV sy-vline
WA_U_16827_STR-WMAAB sy-vline
WA_U_16827_STR-WEKGR sy-vline
WA_U_16827_STR-WVRKM sy-vline
WA_U_16827_STR-WAUSM sy-vline
WA_U_16827_STR-WHERL sy-vline
WA_U_16827_STR-WHERR sy-vline
WA_U_16827_STR-WLADG sy-vline
WA_U_16827_STR-SSTUF sy-vline
WA_U_16827_STR-PFLKS sy-vline
WA_U_16827_STR-LSTFL sy-vline
WA_U_16827_STR-LSTVZ sy-vline
WA_U_16827_STR-LSTAK sy-vline
WA_U_16827_STR-LDVFL sy-vline
WA_U_16827_STR-LDBFL sy-vline
WA_U_16827_STR-LDVZL sy-vline
WA_U_16827_STR-LDBZL sy-vline
WA_U_16827_STR-VDVFL sy-vline
WA_U_16827_STR-VDBFL sy-vline
WA_U_16827_STR-VDVZL sy-vline
WA_U_16827_STR-VDBZL sy-vline
WA_U_16827_STR-WBKLA sy-vline
WA_U_16827_STR-WSTAW sy-vline
WA_U_16827_STR-WPSTA sy-vline
WA_U_16827_STR-WBWSP sy-vline
WA_U_16827_STR-WEXPM sy-vline
WA_U_16827_STR-KWDHT sy-vline
WA_U_16827_STR-PRERF sy-vline
WA_U_16827_STR-RBZUL sy-vline
WA_U_16827_STR-SCAGR sy-vline
WA_U_16827_STR-BWVOR sy-vline
WA_U_16827_STR-BWSCL sy-vline
WA_U_16827_STR-PLGTP sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.