ABAP Select data from SAP table TTEC_SYS_SRC into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP TTEC_SYS_SRC table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to TTEC_SYS_SRC. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the TTEC_SYS_SRC table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_TTEC_SYS_SRC TYPE STANDARD TABLE OF TTEC_SYS_SRC,
WA_TTEC_SYS_SRC TYPE TTEC_SYS_SRC,
GD_STR TYPE STRING.
DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.
FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <TTEC_SYS_SRC> TYPE TTEC_SYS_SRC.
*Process all fields in table header/work area as string values
PERFORM process_as_string_field_values CHANGING wa_TTEC_SYS_SRC.
SELECT *
*restrict ABAP select to first 10 rows
UP TO 10 ROWS
FROM TTEC_SYS_SRC
INTO TABLE IT_TTEC_SYS_SRC.
*Select data and declare internal table using in-line method @DATA
*SELECT *
* FROM TTEC_SYS_SRC
* INTO TABLE @DATA(IT_TTEC_SYS_SRC2).
*--Further methods of using ABAP code to select data from SAP database tables
*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_TTEC_SYS_SRC INDEX 1 INTO DATA(WA_TTEC_SYS_SRC2).
*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_TTEC_SYS_SRC ASSIGNING <TTEC_SYS_SRC>.
*To update a field value using a field symbol simply change the value via the field symbol pointer<TTEC_SYS_SRC>-SYSTEMID1 = 1.
<TTEC_SYS_SRC>-SYSTEMID2 = 1.
<TTEC_SYS_SRC>-SOURCE_CLIENT = 1.
ENDLOOP.
LOOP AT IT_TTEC_SYS_SRC INTO WA_TTEC_SYS_SRC.
*Write horizonal line to screen report.
WRITE:/ sy-uline.
*Write selected data to screen/report before conversion.
WRITE:/ sy-vline, ENDLOOP.
*Add any further fields from structure WA_TTEC_SYS_SRC you want to display...
WRITE:/ sy-uline.
* Aternatively use generic code to Write field values (and NAME) to screen report
DO.
ASSIGN COMPONENT sy-index OF STRUCTURE wa_TTEC_SYS_SRC TO <field>.
IF sy-subrc <> 0. EXIT. ENDIF.
WRITE:/ 'Field Value', <field>, sy-vline.
gd_str = <field> .
lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ).
lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ).
WRITE:/ 'Field Name', lv_fieldname.
ENDDO.
*Redo loop but convert all fields from internal to out value
LOOP AT IT_TTEC_SYS_SRC INTO WA_TTEC_SYS_SRC.
*Write horizonal line to screen report.
WRITE:/ sy-uline.
*Convert all fields to display/output versions using conversion routines
PERFORM convert_all_field_values CHANGING wa_EKKO.
ENDLOOP.
*&---------------------------------------------------------------------*
*& Form convert_all_field_values
*&---------------------------------------------------------------------*
FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO.
DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM.
*&---------------------------------------------------------------------*
*& Form process_as_string_field_values
*&---------------------------------------------------------------------*
FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO.
TYPES: BEGIN OF T_TTEC_SYS_SRC_STR,
SYSTEMID1 TYPE STRING,
SYSTEMID2 TYPE STRING,
SOURCE_CLIENT TYPE STRING,END OF T_EKKO_STR.
DATA: WA_TTEC_SYS_SRC_STR type T_EKKO_STR.
DATA: ld_text TYPE string.
LOOP AT IT_EKKO INTO WA_EKKO.
MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR.
CONCATENATE: sy-vline
WA_TTEC_SYS_SRC_STR-SYSTEMID1 sy-vline
WA_TTEC_SYS_SRC_STR-SYSTEMID2 sy-vline
WA_TTEC_SYS_SRC_STR-SOURCE_CLIENT sy-vline INTO ld_text SEPARATED BY SPACE.
*Add any further fields from structure WA_EKKO_STR you want to CONCATENATE...
ENDLOOP.
ENDFORM.