ABAP Select data from SAP table TSP01SYS into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP TSP01SYS table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to TSP01SYS. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the TSP01SYS table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_TSP01SYS TYPE STANDARD TABLE OF TSP01SYS,
      WA_TSP01SYS TYPE TSP01SYS,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <TSP01SYS> TYPE TSP01SYS.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_TSP01SYS.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM TSP01SYS
  INTO TABLE IT_TSP01SYS.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM TSP01SYS
*  INTO TABLE @DATA(IT_TSP01SYS2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_TSP01SYS INDEX 1 INTO DATA(WA_TSP01SYS2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_TSP01SYS ASSIGNING <TSP01SYS>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<TSP01SYS>-RQIDENT = 1.
<TSP01SYS>-RQCLIENT = 1.
<TSP01SYS>-RQ0NAME = 1.
<TSP01SYS>-RQ1NAME = 1.
<TSP01SYS>-RQ2NAME = 1.
ENDLOOP.

LOOP AT IT_TSP01SYS INTO WA_TSP01SYS.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_TSP01SYS-RQOWNER, sy-vline,
WA_TSP01SYS-RQCMODE, sy-vline,
WA_TSP01SYS-RQFINAL, sy-vline,
WA_TSP01SYS-RQCRETIME, sy-vline,
WA_TSP01SYS-RQDELTIME, sy-vline,
WA_TSP01SYS-RQREARULE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_TSP01SYS you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_TSP01SYS TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_TSP01SYS INTO WA_TSP01SYS. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit SPDEV, internal->external for field RQDEST CALL FUNCTION 'CONVERSION_EXIT_SPDEV_OUTPUT' EXPORTING input = WA_TSP01SYS-RQDEST IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_TSP01SYS-RQDEST.
WRITE:/ 'New Value:', ld_input.

*Conversion exit SPDEV, internal->external for field RQARCHDEST CALL FUNCTION 'CONVERSION_EXIT_SPDEV_OUTPUT' EXPORTING input = WA_TSP01SYS-RQARCHDEST IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_TSP01SYS-RQARCHDEST.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_TSP01SYS_STR,
RQIDENT TYPE STRING,
RQCLIENT TYPE STRING,
RQ0NAME TYPE STRING,
RQ1NAME TYPE STRING,
RQ2NAME TYPE STRING,
RQOWNER TYPE STRING,
RQCMODE TYPE STRING,
RQFINAL TYPE STRING,
RQCRETIME TYPE STRING,
RQDELTIME TYPE STRING,
RQREARULE TYPE STRING,
RQDELRULE TYPE STRING,
RQAPPRULE TYPE STRING,
RQMODRULE TYPE STRING,
RQ1DISPO TYPE STRING,
RQ2DISPO TYPE STRING,
RQ3DISPO TYPE STRING,
RQDEST TYPE STRING,
RQCOPIES TYPE STRING,
RQPRIO TYPE STRING,
RQPAPER TYPE STRING,
RQPJREQ TYPE STRING,
RQPJDONE TYPE STRING,
RQPJSERR TYPE STRING,
RQPJHERR TYPE STRING,
RQWRITER TYPE STRING,
RQERROR TYPE STRING,
RQO1NAME TYPE STRING,
RQO1PART TYPE STRING,
RQO1CLIE TYPE STRING,
RQTITLE TYPE STRING,
RQDELETED TYPE STRING,
RQSAPTITLE TYPE STRING,
RQUNXTITLE TYPE STRING,
RQRECEIVER TYPE STRING,
RQDIVISION TYPE STRING,
RQARCHTYPE TYPE STRING,
RQARCHDEST TYPE STRING,
RQARCHSTAT TYPE STRING,
RQAUTH TYPE STRING,
RQISPROTOK TYPE STRING,
RQTELELAN TYPE STRING,
RQTELENUM TYPE STRING,
RQTELENUME TYPE STRING,
RQMODTIME TYPE STRING,
RQDOCTYPE TYPE STRING,
RQPOSNAME TYPE STRING,
SYS TYPE STRING,END OF T_EKKO_STR. DATA: WA_TSP01SYS_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_TSP01SYS_STR-RQIDENT sy-vline
WA_TSP01SYS_STR-RQCLIENT sy-vline
WA_TSP01SYS_STR-RQ0NAME sy-vline
WA_TSP01SYS_STR-RQ1NAME sy-vline
WA_TSP01SYS_STR-RQ2NAME sy-vline
WA_TSP01SYS_STR-RQOWNER sy-vline
WA_TSP01SYS_STR-RQCMODE sy-vline
WA_TSP01SYS_STR-RQFINAL sy-vline
WA_TSP01SYS_STR-RQCRETIME sy-vline
WA_TSP01SYS_STR-RQDELTIME sy-vline
WA_TSP01SYS_STR-RQREARULE sy-vline
WA_TSP01SYS_STR-RQDELRULE sy-vline
WA_TSP01SYS_STR-RQAPPRULE sy-vline
WA_TSP01SYS_STR-RQMODRULE sy-vline
WA_TSP01SYS_STR-RQ1DISPO sy-vline
WA_TSP01SYS_STR-RQ2DISPO sy-vline
WA_TSP01SYS_STR-RQ3DISPO sy-vline
WA_TSP01SYS_STR-RQDEST sy-vline
WA_TSP01SYS_STR-RQCOPIES sy-vline
WA_TSP01SYS_STR-RQPRIO sy-vline
WA_TSP01SYS_STR-RQPAPER sy-vline
WA_TSP01SYS_STR-RQPJREQ sy-vline
WA_TSP01SYS_STR-RQPJDONE sy-vline
WA_TSP01SYS_STR-RQPJSERR sy-vline
WA_TSP01SYS_STR-RQPJHERR sy-vline
WA_TSP01SYS_STR-RQWRITER sy-vline
WA_TSP01SYS_STR-RQERROR sy-vline
WA_TSP01SYS_STR-RQO1NAME sy-vline
WA_TSP01SYS_STR-RQO1PART sy-vline
WA_TSP01SYS_STR-RQO1CLIE sy-vline
WA_TSP01SYS_STR-RQTITLE sy-vline
WA_TSP01SYS_STR-RQDELETED sy-vline
WA_TSP01SYS_STR-RQSAPTITLE sy-vline
WA_TSP01SYS_STR-RQUNXTITLE sy-vline
WA_TSP01SYS_STR-RQRECEIVER sy-vline
WA_TSP01SYS_STR-RQDIVISION sy-vline
WA_TSP01SYS_STR-RQARCHTYPE sy-vline
WA_TSP01SYS_STR-RQARCHDEST sy-vline
WA_TSP01SYS_STR-RQARCHSTAT sy-vline
WA_TSP01SYS_STR-RQAUTH sy-vline
WA_TSP01SYS_STR-RQISPROTOK sy-vline
WA_TSP01SYS_STR-RQTELELAN sy-vline
WA_TSP01SYS_STR-RQTELENUM sy-vline
WA_TSP01SYS_STR-RQTELENUME sy-vline
WA_TSP01SYS_STR-RQMODTIME sy-vline
WA_TSP01SYS_STR-RQDOCTYPE sy-vline
WA_TSP01SYS_STR-RQPOSNAME sy-vline
WA_TSP01SYS_STR-SYS sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.