ABAP Select data from SAP table TRLS_SUBPOS_DISPLAY into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP TRLS_SUBPOS_DISPLAY table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to TRLS_SUBPOS_DISPLAY. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the TRLS_SUBPOS_DISPLAY table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_TRLS_SUBPOS_DISPLAY TYPE STANDARD TABLE OF TRLS_SUBPOS_DISPLAY,
      WA_TRLS_SUBPOS_DISPLAY TYPE TRLS_SUBPOS_DISPLAY,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <TRLS_SUBPOS_DISPLAY> TYPE TRLS_SUBPOS_DISPLAY.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_TRLS_SUBPOS_DISPLAY.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM TRLS_SUBPOS_DISPLAY
  INTO TABLE IT_TRLS_SUBPOS_DISPLAY.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM TRLS_SUBPOS_DISPLAY
*  INTO TABLE @DATA(IT_TRLS_SUBPOS_DISPLAY2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_TRLS_SUBPOS_DISPLAY INDEX 1 INTO DATA(WA_TRLS_SUBPOS_DISPLAY2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_TRLS_SUBPOS_DISPLAY ASSIGNING <TRLS_SUBPOS_DISPLAY>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<TRLS_SUBPOS_DISPLAY>-POSITION_OID = 1.
<TRLS_SUBPOS_DISPLAY>-SUBPOSITION_OID = 1.
<TRLS_SUBPOS_DISPLAY>-PA_COMPANY_ID = 1.
<TRLS_SUBPOS_DISPLAY>-ORIGIN_DATE = 1.
<TRLS_SUBPOS_DISPLAY>-HINST_OID = 1.
ENDLOOP.

LOOP AT IT_TRLS_SUBPOS_DISPLAY INTO WA_TRLS_SUBPOS_DISPLAY.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_TRLS_SUBPOS_DISPLAY-HITEM_OID, sy-vline,
WA_TRLS_SUBPOS_DISPLAY-FLG_FREESTANDING, sy-vline,
WA_TRLS_SUBPOS_DISPLAY-DESIG_UNITS, sy-vline,
WA_TRLS_SUBPOS_DISPLAY-DESIG_NOMINAL_AMT, sy-vline,
WA_TRLS_SUBPOS_DISPLAY-DESIG_NOMINAL_ORG_AMT, sy-vline,
WA_TRLS_SUBPOS_DISPLAY-NOMINAL_CURR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_TRLS_SUBPOS_DISPLAY you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_TRLS_SUBPOS_DISPLAY TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_TRLS_SUBPOS_DISPLAY INTO WA_TRLS_SUBPOS_DISPLAY. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field PA_COMPANY_ID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_TRLS_SUBPOS_DISPLAY-PA_COMPANY_ID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_TRLS_SUBPOS_DISPLAY-PA_COMPANY_ID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UNIT_OF_MEASURE CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_TRLS_SUBPOS_DISPLAY-UNIT_OF_MEASURE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_TRLS_SUBPOS_DISPLAY-UNIT_OF_MEASURE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field HITEM_NUMBER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_TRLS_SUBPOS_DISPLAY-HITEM_NUMBER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_TRLS_SUBPOS_DISPLAY-HITEM_NUMBER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field HITEM_FISCAL_YEAR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_TRLS_SUBPOS_DISPLAY-HITEM_FISCAL_YEAR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_TRLS_SUBPOS_DISPLAY-HITEM_FISCAL_YEAR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field HINST_NUMBER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_TRLS_SUBPOS_DISPLAY-HINST_NUMBER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_TRLS_SUBPOS_DISPLAY-HINST_NUMBER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field HINST_FISCAL_YEAR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_TRLS_SUBPOS_DISPLAY-HINST_FISCAL_YEAR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_TRLS_SUBPOS_DISPLAY-HINST_FISCAL_YEAR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field HREL_NUMBER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_TRLS_SUBPOS_DISPLAY-HREL_NUMBER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_TRLS_SUBPOS_DISPLAY-HREL_NUMBER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field HREL_FISCAL_YEAR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_TRLS_SUBPOS_DISPLAY-HREL_FISCAL_YEAR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_TRLS_SUBPOS_DISPLAY-HREL_FISCAL_YEAR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field HREL_PROFILE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_TRLS_SUBPOS_DISPLAY-HREL_PROFILE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_TRLS_SUBPOS_DISPLAY-HREL_PROFILE.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_TRLS_SUBPOS_DISPLAY_STR,
POSITION_OID TYPE STRING,
SUBPOSITION_OID TYPE STRING,
PA_COMPANY_ID TYPE STRING,
ORIGIN_DATE TYPE STRING,
HINST_OID TYPE STRING,
HITEM_OID TYPE STRING,
FLG_FREESTANDING TYPE STRING,
DESIG_UNITS TYPE STRING,
DESIG_NOMINAL_AMT TYPE STRING,
DESIG_NOMINAL_ORG_AMT TYPE STRING,
NOMINAL_CURR TYPE STRING,
POSITION_CURR TYPE STRING,
VALUATION_CURR TYPE STRING,
INTERN_TO_BE_CLASSIFIED_PC TYPE STRING,
INTERN_TO_BE_CLASSIFIED_VC TYPE STRING,
HADJ_PC TYPE STRING,
HADJ_IDXCL_PC TYPE STRING,
HADJ_VC TYPE STRING,
HAMORT_PC TYPE STRING,
HAMORT_IDXCL_PC TYPE STRING,
HAMORT_VC TYPE STRING,
EFF_PC TYPE STRING,
EFF_VC TYPE STRING,
EFF_IDXCL_PC TYPE STRING,
INEFF_PC TYPE STRING,
INEFF_VC TYPE STRING,
INEFF_IDXCL_PC TYPE STRING,
EFFD_PC TYPE STRING,
EFFD_VC TYPE STRING,
EFFD_IDXCL_PC TYPE STRING,
INEFFD_PC TYPE STRING,
INEFFD_VC TYPE STRING,
INEFFD_IDXCL_PC TYPE STRING,
FX_RISK TYPE STRING,
IR_RISK TYPE STRING,
PRICE_RISK TYPE STRING,
PURCH_PC TYPE STRING,
PURCH_IDXCL_PC TYPE STRING,
PURCH_VC TYPE STRING,
VAL_TI_PC TYPE STRING,
VAL_TI_IDXCL_PC TYPE STRING,
VAL_TI_VC TYPE STRING,
VAL_FX_VC TYPE STRING,
VAL_TI_NPL_PC TYPE STRING,
VAL_TI_NPL_IDXCL_PC TYPE STRING,
VAL_TI_NPL_VC TYPE STRING,
VAL_FX_NPL_VC TYPE STRING,
CHARGE_PC TYPE STRING,
CHARGE_IDXCL_PC TYPE STRING,
CHARGE_VC TYPE STRING,
VAL_CH_TI_PC TYPE STRING,
VAL_CH_TI_IDXCL_PC TYPE STRING,
VAL_CH_TI_UP_PC TYPE STRING,
VAL_CH_TI_DOWN_PC TYPE STRING,
VAL_CH_TI_VC TYPE STRING,
VAL_CH_TI_UP_VC TYPE STRING,
VAL_CH_TI_DOWN_VC TYPE STRING,
VAL_CH_FX_VC TYPE STRING,
VAL_CH_FX_UP_VC TYPE STRING,
VAL_CH_FX_DOWN_VC TYPE STRING,
AMORT_PC TYPE STRING,
AMORT_IDXCL_PC TYPE STRING,
AMORT_VC TYPE STRING,
AMORT_NEG_SPR_PC TYPE STRING,
AMORT_NEG_SPR_IDXCL_PC TYPE STRING,
AMORT_NEG_SPR_VC TYPE STRING,
VAL_FX_AMAQU_VAL_VC TYPE STRING,
VAL_CH_TI_NPL_PC TYPE STRING,
VAL_CH_TI_NPL_IDXCL_PC TYPE STRING,
VAL_CH_TI_NPL_VC TYPE STRING,
VAL_CH_FX_NPL_VC TYPE STRING,
CONS_GAINS_TI_PC TYPE STRING,
CONS_GAINS_TI_VC TYPE STRING,
CONS_LOSSES_TI_PC TYPE STRING,
CONS_LOSSES_TI_VC TYPE STRING,
CONS_GAINS_FX_VC TYPE STRING,
CONS_LOSSES_FX_VC TYPE STRING,
VAD_GAIN_PC TYPE STRING,
VAD_GAIN_VC TYPE STRING,
VAD_LOSS_PC TYPE STRING,
VAD_LOSS_VC TYPE STRING,
ORIG_VAD_PC TYPE STRING,
ORIG_VAD_VC TYPE STRING,
IMPMNT_PC TYPE STRING,
IMPMNT_IDXCL_PC TYPE STRING,
IMPMNT_VC TYPE STRING,
IMPMNT_FX_VC TYPE STRING,
AQU_VAL_PC TYPE STRING,
AQU_VAL_IDXCL_PC TYPE STRING,
AQU_VAL_VC TYPE STRING,
AMAQU_VAL_PC TYPE STRING,
AMAQU_VAL_IDXCL_PC TYPE STRING,
AMAQU_VAL_VC TYPE STRING,
BOOK_VAL_PC TYPE STRING,
BOOK_VAL_IDXCL_PC TYPE STRING,
BOOK_VAL_VC TYPE STRING,
BOOK_VAL_EX_PC TYPE STRING,
BOOK_VAL_EX_IDXCL_PC TYPE STRING,
BOOK_VAL_EX_VC TYPE STRING,
EFF_COST_HR_PC TYPE STRING,
EFF_COST_HR_VC TYPE STRING,
EFF_COST_HR_IDXCL_PC TYPE STRING,
INEFF_COST_HR_PC TYPE STRING,
INEFF_COST_HR_VC TYPE STRING,
INEFF_COST_HR_IDXCL_PC TYPE STRING,
INEFF_HR_PC TYPE STRING,
INEFF_HR_VC TYPE STRING,
INEFF_HR_IDXCL_PC TYPE STRING,
EFF_COST_HR_TPL_PC TYPE STRING,
EFF_COST_HR_TPL_VC TYPE STRING,
EFF_COST_HR_TPL_IDXCL_PC TYPE STRING,
EFF_HR_TPL_PC TYPE STRING,
EFF_HR_TPL_VC TYPE STRING,
EFF_HR_TPL_IDXCL_PC TYPE STRING,
PL_EFF_DES_PC TYPE STRING,
PL_EFF_DES_VC TYPE STRING,
PL_EFF_DES_IDXCL_PC TYPE STRING,
PL_EFF_NON_DES_PC TYPE STRING,
PL_EFF_NON_DES_VC TYPE STRING,
PL_EFF_NON_DES_IDXCL_PC TYPE STRING,
AMRT_NON_DES_PC TYPE STRING,
AMRT_NON_DES_VC TYPE STRING,
AMRT_NON_DES_IDXCL_PC TYPE STRING,
VAL_IDX_PC TYPE STRING,
VAL_IDX_VC TYPE STRING,
DCSID TYPE STRING,
QUANTITY TYPE STRING,
UNIT_OF_MEASURE TYPE STRING,
HITEM_NUMBER TYPE STRING,
HITEM_FISCAL_YEAR TYPE STRING,
HINST_NUMBER TYPE STRING,
HINST_FISCAL_YEAR TYPE STRING,
HITEM_DESCR TYPE STRING,
HINST_DESCR TYPE STRING,
HREL_NUMBER TYPE STRING,
HREL_FISCAL_YEAR TYPE STRING,
HREL_PROFILE TYPE STRING,
HREL_DESCR TYPE STRING,
HREL_CATEGORY TYPE STRING,
HREL_DISP_STATUS TYPE STRING,
HREL_DISP_STATUS_T TYPE STRING,
DCSID_T TYPE STRING,
UNIT_OF_MEASURE_T TYPE STRING,END OF T_EKKO_STR. DATA: WA_TRLS_SUBPOS_DISPLAY_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-POSITION_OID sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-SUBPOSITION_OID sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-PA_COMPANY_ID sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-ORIGIN_DATE sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-HINST_OID sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-HITEM_OID sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-FLG_FREESTANDING sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-DESIG_UNITS sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-DESIG_NOMINAL_AMT sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-DESIG_NOMINAL_ORG_AMT sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-NOMINAL_CURR sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-POSITION_CURR sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-VALUATION_CURR sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-INTERN_TO_BE_CLASSIFIED_PC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-INTERN_TO_BE_CLASSIFIED_VC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-HADJ_PC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-HADJ_IDXCL_PC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-HADJ_VC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-HAMORT_PC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-HAMORT_IDXCL_PC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-HAMORT_VC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-EFF_PC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-EFF_VC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-EFF_IDXCL_PC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-INEFF_PC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-INEFF_VC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-INEFF_IDXCL_PC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-EFFD_PC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-EFFD_VC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-EFFD_IDXCL_PC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-INEFFD_PC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-INEFFD_VC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-INEFFD_IDXCL_PC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-FX_RISK sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-IR_RISK sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-PRICE_RISK sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-PURCH_PC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-PURCH_IDXCL_PC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-PURCH_VC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-VAL_TI_PC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-VAL_TI_IDXCL_PC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-VAL_TI_VC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-VAL_FX_VC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-VAL_TI_NPL_PC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-VAL_TI_NPL_IDXCL_PC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-VAL_TI_NPL_VC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-VAL_FX_NPL_VC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-CHARGE_PC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-CHARGE_IDXCL_PC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-CHARGE_VC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-VAL_CH_TI_PC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-VAL_CH_TI_IDXCL_PC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-VAL_CH_TI_UP_PC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-VAL_CH_TI_DOWN_PC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-VAL_CH_TI_VC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-VAL_CH_TI_UP_VC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-VAL_CH_TI_DOWN_VC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-VAL_CH_FX_VC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-VAL_CH_FX_UP_VC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-VAL_CH_FX_DOWN_VC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-AMORT_PC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-AMORT_IDXCL_PC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-AMORT_VC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-AMORT_NEG_SPR_PC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-AMORT_NEG_SPR_IDXCL_PC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-AMORT_NEG_SPR_VC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-VAL_FX_AMAQU_VAL_VC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-VAL_CH_TI_NPL_PC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-VAL_CH_TI_NPL_IDXCL_PC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-VAL_CH_TI_NPL_VC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-VAL_CH_FX_NPL_VC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-CONS_GAINS_TI_PC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-CONS_GAINS_TI_VC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-CONS_LOSSES_TI_PC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-CONS_LOSSES_TI_VC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-CONS_GAINS_FX_VC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-CONS_LOSSES_FX_VC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-VAD_GAIN_PC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-VAD_GAIN_VC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-VAD_LOSS_PC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-VAD_LOSS_VC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-ORIG_VAD_PC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-ORIG_VAD_VC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-IMPMNT_PC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-IMPMNT_IDXCL_PC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-IMPMNT_VC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-IMPMNT_FX_VC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-AQU_VAL_PC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-AQU_VAL_IDXCL_PC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-AQU_VAL_VC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-AMAQU_VAL_PC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-AMAQU_VAL_IDXCL_PC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-AMAQU_VAL_VC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-BOOK_VAL_PC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-BOOK_VAL_IDXCL_PC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-BOOK_VAL_VC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-BOOK_VAL_EX_PC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-BOOK_VAL_EX_IDXCL_PC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-BOOK_VAL_EX_VC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-EFF_COST_HR_PC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-EFF_COST_HR_VC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-EFF_COST_HR_IDXCL_PC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-INEFF_COST_HR_PC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-INEFF_COST_HR_VC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-INEFF_COST_HR_IDXCL_PC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-INEFF_HR_PC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-INEFF_HR_VC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-INEFF_HR_IDXCL_PC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-EFF_COST_HR_TPL_PC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-EFF_COST_HR_TPL_VC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-EFF_COST_HR_TPL_IDXCL_PC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-EFF_HR_TPL_PC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-EFF_HR_TPL_VC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-EFF_HR_TPL_IDXCL_PC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-PL_EFF_DES_PC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-PL_EFF_DES_VC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-PL_EFF_DES_IDXCL_PC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-PL_EFF_NON_DES_PC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-PL_EFF_NON_DES_VC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-PL_EFF_NON_DES_IDXCL_PC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-AMRT_NON_DES_PC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-AMRT_NON_DES_VC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-AMRT_NON_DES_IDXCL_PC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-VAL_IDX_PC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-VAL_IDX_VC sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-DCSID sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-QUANTITY sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-UNIT_OF_MEASURE sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-HITEM_NUMBER sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-HITEM_FISCAL_YEAR sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-HINST_NUMBER sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-HINST_FISCAL_YEAR sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-HITEM_DESCR sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-HINST_DESCR sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-HREL_NUMBER sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-HREL_FISCAL_YEAR sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-HREL_PROFILE sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-HREL_DESCR sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-HREL_CATEGORY sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-HREL_DISP_STATUS sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-HREL_DISP_STATUS_T sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-DCSID_T sy-vline
WA_TRLS_SUBPOS_DISPLAY_STR-UNIT_OF_MEASURE_T sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.