ABAP Select data from SAP table TQ07A_TL into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP TQ07A_TL table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to TQ07A_TL. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the TQ07A_TL table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_TQ07A_TL TYPE STANDARD TABLE OF TQ07A_TL,
      WA_TQ07A_TL TYPE TQ07A_TL,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <TQ07A_TL> TYPE TQ07A_TL.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_TQ07A_TL.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM TQ07A_TL
  INTO TABLE IT_TQ07A_TL.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM TQ07A_TL
*  INTO TABLE @DATA(IT_TQ07A_TL2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_TQ07A_TL INDEX 1 INTO DATA(WA_TQ07A_TL2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_TQ07A_TL ASSIGNING <TQ07A_TL>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<TQ07A_TL>-TEILLOS = 1.
<TQ07A_TL>-MANDT = 1.
<TQ07A_TL>-FOLGEAKTI = 1.
<TQ07A_TL>-ZAEHLER = 1.
<TQ07A_TL>-FKTBST = 1.
ENDLOOP.

LOOP AT IT_TQ07A_TL INTO WA_TQ07A_TL.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_TQ07A_TL-NACH_VERBU, sy-vline,
WA_TQ07A_TL-SYNC_VERBU, sy-vline,
WA_TQ07A_TL-SCHLUESSEL, sy-vline,
ENDLOOP. *Add any further fields from structure WA_TQ07A_TL you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_TQ07A_TL TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_TQ07A_TL INTO WA_TQ07A_TL. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_TQ07A_TL_STR,
TEILLOS TYPE STRING,
MANDT TYPE STRING,
FOLGEAKTI TYPE STRING,
ZAEHLER TYPE STRING,
FKTBST TYPE STRING,
NACH_VERBU TYPE STRING,
SYNC_VERBU TYPE STRING,
SCHLUESSEL TYPE STRING,END OF T_EKKO_STR. DATA: WA_TQ07A_TL_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_TQ07A_TL_STR-TEILLOS sy-vline
WA_TQ07A_TL_STR-MANDT sy-vline
WA_TQ07A_TL_STR-FOLGEAKTI sy-vline
WA_TQ07A_TL_STR-ZAEHLER sy-vline
WA_TQ07A_TL_STR-FKTBST sy-vline
WA_TQ07A_TL_STR-NACH_VERBU sy-vline
WA_TQ07A_TL_STR-SYNC_VERBU sy-vline
WA_TQ07A_TL_STR-SCHLUESSEL sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.