ABAP Select data from SAP table TPDA_TOOL_GL_STACK_DATA into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP TPDA_TOOL_GL_STACK_DATA table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to TPDA_TOOL_GL_STACK_DATA. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the TPDA_TOOL_GL_STACK_DATA table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_TPDA_TOOL_GL_STACK_DATA TYPE STANDARD TABLE OF TPDA_TOOL_GL_STACK_DATA,
      WA_TPDA_TOOL_GL_STACK_DATA TYPE TPDA_TOOL_GL_STACK_DATA,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <TPDA_TOOL_GL_STACK_DATA> TYPE TPDA_TOOL_GL_STACK_DATA.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_TPDA_TOOL_GL_STACK_DATA.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM TPDA_TOOL_GL_STACK_DATA
  INTO TABLE IT_TPDA_TOOL_GL_STACK_DATA.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM TPDA_TOOL_GL_STACK_DATA
*  INTO TABLE @DATA(IT_TPDA_TOOL_GL_STACK_DATA2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_TPDA_TOOL_GL_STACK_DATA INDEX 1 INTO DATA(WA_TPDA_TOOL_GL_STACK_DATA2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_TPDA_TOOL_GL_STACK_DATA ASSIGNING <TPDA_TOOL_GL_STACK_DATA>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<TPDA_TOOL_GL_STACK_DATA>-IT_STACK_TC = 1.
<TPDA_TOOL_GL_STACK_DATA>-WA_STACK_LINE_TC = 1.
<TPDA_TOOL_GL_STACK_DATA>-STACKPOINTER = 1.
<TPDA_TOOL_GL_STACK_DATA>-STACKLEVEL = 1.
<TPDA_TOOL_GL_STACK_DATA>-STACKINDEX = 1.
ENDLOOP.

LOOP AT IT_TPDA_TOOL_GL_STACK_DATA INTO WA_TPDA_TOOL_GL_STACK_DATA.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_TPDA_TOOL_GL_STACK_DATA-IMODELEVEL, sy-vline,
WA_TPDA_TOOL_GL_STACK_DATA-ENHANCELEVEL, sy-vline,
WA_TPDA_TOOL_GL_STACK_DATA-SYSTEMPROG, sy-vline,
WA_TPDA_TOOL_GL_STACK_DATA-FLAGDYNPCONT, sy-vline,
WA_TPDA_TOOL_GL_STACK_DATA-PROGRAM, sy-vline,
WA_TPDA_TOOL_GL_STACK_DATA-INCLUDE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_TPDA_TOOL_GL_STACK_DATA you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_TPDA_TOOL_GL_STACK_DATA TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_TPDA_TOOL_GL_STACK_DATA INTO WA_TPDA_TOOL_GL_STACK_DATA. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_TPDA_TOOL_GL_STACK_DATA_STR,
IT_STACK_TC TYPE STRING,
WA_STACK_LINE_TC TYPE STRING,
STACKPOINTER TYPE STRING,
STACKLEVEL TYPE STRING,
STACKINDEX TYPE STRING,
IMODELEVEL TYPE STRING,
ENHANCELEVEL TYPE STRING,
SYSTEMPROG TYPE STRING,
FLAGDYNPCONT TYPE STRING,
PROGRAM TYPE STRING,
INCLUDE TYPE STRING,
LINE TYPE STRING,
EVENTTYPE TYPE STRING,
EVENTNAME TYPE STRING,
LOCCLASSNAME TYPE STRING,
FLAG_EOEV TYPE STRING,
FLAG_EOEV_NOLREF TYPE STRING,
ACTION1 TYPE STRING,
STACK_KIND TYPE STRING,
MERGE TYPE STRING,
SUBINDEX TYPE STRING,
NAVI_PROG TYPE STRING,
NAVI_DYNNR TYPE STRING,
TITLE TYPE STRING,END OF T_EKKO_STR. DATA: WA_TPDA_TOOL_GL_STACK_DATA_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_TPDA_TOOL_GL_STACK_DATA_STR-IT_STACK_TC sy-vline
WA_TPDA_TOOL_GL_STACK_DATA_STR-WA_STACK_LINE_TC sy-vline
WA_TPDA_TOOL_GL_STACK_DATA_STR-STACKPOINTER sy-vline
WA_TPDA_TOOL_GL_STACK_DATA_STR-STACKLEVEL sy-vline
WA_TPDA_TOOL_GL_STACK_DATA_STR-STACKINDEX sy-vline
WA_TPDA_TOOL_GL_STACK_DATA_STR-IMODELEVEL sy-vline
WA_TPDA_TOOL_GL_STACK_DATA_STR-ENHANCELEVEL sy-vline
WA_TPDA_TOOL_GL_STACK_DATA_STR-SYSTEMPROG sy-vline
WA_TPDA_TOOL_GL_STACK_DATA_STR-FLAGDYNPCONT sy-vline
WA_TPDA_TOOL_GL_STACK_DATA_STR-PROGRAM sy-vline
WA_TPDA_TOOL_GL_STACK_DATA_STR-INCLUDE sy-vline
WA_TPDA_TOOL_GL_STACK_DATA_STR-LINE sy-vline
WA_TPDA_TOOL_GL_STACK_DATA_STR-EVENTTYPE sy-vline
WA_TPDA_TOOL_GL_STACK_DATA_STR-EVENTNAME sy-vline
WA_TPDA_TOOL_GL_STACK_DATA_STR-LOCCLASSNAME sy-vline
WA_TPDA_TOOL_GL_STACK_DATA_STR-FLAG_EOEV sy-vline
WA_TPDA_TOOL_GL_STACK_DATA_STR-FLAG_EOEV_NOLREF sy-vline
WA_TPDA_TOOL_GL_STACK_DATA_STR-ACTION1 sy-vline
WA_TPDA_TOOL_GL_STACK_DATA_STR-STACK_KIND sy-vline
WA_TPDA_TOOL_GL_STACK_DATA_STR-MERGE sy-vline
WA_TPDA_TOOL_GL_STACK_DATA_STR-SUBINDEX sy-vline
WA_TPDA_TOOL_GL_STACK_DATA_STR-NAVI_PROG sy-vline
WA_TPDA_TOOL_GL_STACK_DATA_STR-NAVI_DYNNR sy-vline
WA_TPDA_TOOL_GL_STACK_DATA_STR-TITLE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.