ABAP Select data from SAP table TNCDF1 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP TNCDF1 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to TNCDF1. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the TNCDF1 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_TNCDF1 TYPE STANDARD TABLE OF TNCDF1,
      WA_TNCDF1 TYPE TNCDF1,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <TNCDF1> TYPE TNCDF1.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_TNCDF1.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM TNCDF1
  INTO TABLE IT_TNCDF1.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM TNCDF1
*  INTO TABLE @DATA(IT_TNCDF12).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_TNCDF1 INDEX 1 INTO DATA(WA_TNCDF12).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_TNCDF1 ASSIGNING <TNCDF1>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<TNCDF1>-MANDT = 1.
<TNCDF1>-EINRI = 1.
<TNCDF1>-CDFID = 1.
<TNCDF1>-NINOUTSIGN = 1.
<TNCDF1>-CDFACTIV = 1.
ENDLOOP.

LOOP AT IT_TNCDF1 INTO WA_TNCDF1.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_TNCDF1-FUNAM, sy-vline,
WA_TNCDF1-RFCDEST, sy-vline,
WA_TNCDF1-SYNCHRON, sy-vline,
WA_TNCDF1-DIRLINKID, sy-vline,
WA_TNCDF1-DRG_CAT, sy-vline,
WA_TNCDF1-MDC_CAT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_TNCDF1 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_TNCDF1 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_TNCDF1 INTO WA_TNCDF1. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field EINRI CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_TNCDF1-EINRI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_TNCDF1-EINRI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field DRG_CAT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_TNCDF1-DRG_CAT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_TNCDF1-DRG_CAT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_TNCDF1_STR,
MANDT TYPE STRING,
EINRI TYPE STRING,
CDFID TYPE STRING,
NINOUTSIGN TYPE STRING,
CDFACTIV TYPE STRING,
FUNAM TYPE STRING,
RFCDEST TYPE STRING,
SYNCHRON TYPE STRING,
DIRLINKID TYPE STRING,
DRG_CAT TYPE STRING,
MDC_CAT TYPE STRING,
CMDTAG TYPE STRING,
PAYTAG TYPE STRING,
SYSTAG TYPE STRING,
OTHERTAG TYPE STRING,
ERDAT TYPE STRING,
ERTIM TYPE STRING,
ERUSR TYPE STRING,
UPDAT TYPE STRING,
UPTIM TYPE STRING,
UPUSR TYPE STRING,
FUNAM2 TYPE STRING,
RFCDEST2 TYPE STRING,
EXTVERS TYPE STRING,
OPTSING TYPE STRING,
OPTMASS TYPE STRING,
OPTBKGR TYPE STRING,END OF T_EKKO_STR. DATA: WA_TNCDF1_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_TNCDF1_STR-MANDT sy-vline
WA_TNCDF1_STR-EINRI sy-vline
WA_TNCDF1_STR-CDFID sy-vline
WA_TNCDF1_STR-NINOUTSIGN sy-vline
WA_TNCDF1_STR-CDFACTIV sy-vline
WA_TNCDF1_STR-FUNAM sy-vline
WA_TNCDF1_STR-RFCDEST sy-vline
WA_TNCDF1_STR-SYNCHRON sy-vline
WA_TNCDF1_STR-DIRLINKID sy-vline
WA_TNCDF1_STR-DRG_CAT sy-vline
WA_TNCDF1_STR-MDC_CAT sy-vline
WA_TNCDF1_STR-CMDTAG sy-vline
WA_TNCDF1_STR-PAYTAG sy-vline
WA_TNCDF1_STR-SYSTAG sy-vline
WA_TNCDF1_STR-OTHERTAG sy-vline
WA_TNCDF1_STR-ERDAT sy-vline
WA_TNCDF1_STR-ERTIM sy-vline
WA_TNCDF1_STR-ERUSR sy-vline
WA_TNCDF1_STR-UPDAT sy-vline
WA_TNCDF1_STR-UPTIM sy-vline
WA_TNCDF1_STR-UPUSR sy-vline
WA_TNCDF1_STR-FUNAM2 sy-vline
WA_TNCDF1_STR-RFCDEST2 sy-vline
WA_TNCDF1_STR-EXTVERS sy-vline
WA_TNCDF1_STR-OPTSING sy-vline
WA_TNCDF1_STR-OPTMASS sy-vline
WA_TNCDF1_STR-OPTBKGR sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.