ABAP Select data from SAP table TNC301GC into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP TNC301GC table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to TNC301GC. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the TNC301GC table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_TNC301GC TYPE STANDARD TABLE OF TNC301GC,
      WA_TNC301GC TYPE TNC301GC,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <TNC301GC> TYPE TNC301GC.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_TNC301GC.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM TNC301GC
  INTO TABLE IT_TNC301GC.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM TNC301GC
*  INTO TABLE @DATA(IT_TNC301GC2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_TNC301GC INDEX 1 INTO DATA(WA_TNC301GC2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_TNC301GC ASSIGNING <TNC301GC>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<TNC301GC>-EDIPROC = 1.
<TNC301GC>-ARBGB = 1.
<TNC301GC>-MSGNR = 1.
<TNC301GC>-FUNAM = 1.
<TNC301GC>-ACTIVE = 1.
ENDLOOP.

LOOP AT IT_TNC301GC INTO WA_TNC301GC.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_TNC301GC-INACTIVE, sy-vline,
WA_TNC301GC-MSGTYP, sy-vline,
WA_TNC301GC-RSTATUS, sy-vline,
ENDLOOP. *Add any further fields from structure WA_TNC301GC you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_TNC301GC TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_TNC301GC INTO WA_TNC301GC. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_TNC301GC_STR,
EDIPROC TYPE STRING,
ARBGB TYPE STRING,
MSGNR TYPE STRING,
FUNAM TYPE STRING,
ACTIVE TYPE STRING,
INACTIVE TYPE STRING,
MSGTYP TYPE STRING,
RSTATUS TYPE STRING,END OF T_EKKO_STR. DATA: WA_TNC301GC_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_TNC301GC_STR-EDIPROC sy-vline
WA_TNC301GC_STR-ARBGB sy-vline
WA_TNC301GC_STR-MSGNR sy-vline
WA_TNC301GC_STR-FUNAM sy-vline
WA_TNC301GC_STR-ACTIVE sy-vline
WA_TNC301GC_STR-INACTIVE sy-vline
WA_TNC301GC_STR-MSGTYP sy-vline
WA_TNC301GC_STR-RSTATUS sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.