ABAP Select data from SAP table TMW_ASTATS_TSCON into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP TMW_ASTATS_TSCON table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to TMW_ASTATS_TSCON. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the TMW_ASTATS_TSCON table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_TMW_ASTATS_TSCON TYPE STANDARD TABLE OF TMW_ASTATS_TSCON, WA_TMW_ASTATS_TSCON TYPE TMW_ASTATS_TSCON, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <TMW_ASTATS_TSCON> TYPE TMW_ASTATS_TSCON. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_TMW_ASTATS_TSCON. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM TMW_ASTATS_TSCON INTO TABLE IT_TMW_ASTATS_TSCON. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM TMW_ASTATS_TSCON * INTO TABLE @DATA(IT_TMW_ASTATS_TSCON2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_TMW_ASTATS_TSCON INDEX 1 INTO DATA(WA_TMW_ASTATS_TSCON2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_TMW_ASTATS_TSCON ASSIGNING <TMW_ASTATS_TSCON>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<TMW_ASTATS_TSCON>-CUSTMNR = 1.
<TMW_ASTATS_TSCON>-OBJTYPE = 1.
<TMW_ASTATS_TSCON>-OBJNAME = 1.
<TMW_ASTATS_TSCON>-TEXTKEY = 1.
<TMW_ASTATS_TSCON>-STATS_S = 1.
ENDLOOP. LOOP AT IT_TMW_ASTATS_TSCON INTO WA_TMW_ASTATS_TSCON. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_TMW_ASTATS_TSCON-MATCH_100, sy-vline,
WA_TMW_ASTATS_TSCON-MATCH_50TO74, sy-vline,
WA_TMW_ASTATS_TSCON-MATCH_75TO84, sy-vline,
WA_TMW_ASTATS_TSCON-MATCH_85TO94, sy-vline,
WA_TMW_ASTATS_TSCON-MATCH_95TO99, sy-vline,
WA_TMW_ASTATS_TSCON-NOMATCH, sy-vline.
ENDLOOP. *Add any further fields from structure WA_TMW_ASTATS_TSCON you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_TMW_ASTATS_TSCON TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_TMW_ASTATS_TSCON INTO WA_TMW_ASTATS_TSCON. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_TMW_ASTATS_TSCON_STR,
CUSTMNR TYPE STRING,
OBJTYPE TYPE STRING,
OBJNAME TYPE STRING,
TEXTKEY TYPE STRING,
STATS_S TYPE STRING,
MATCH_100 TYPE STRING,
MATCH_50TO74 TYPE STRING,
MATCH_75TO84 TYPE STRING,
MATCH_85TO94 TYPE STRING,
MATCH_95TO99 TYPE STRING,
NOMATCH TYPE STRING,
REPEATED TYPE STRING,
TOTAL TYPE STRING,
XTRANSLATED TYPE STRING,
CONTEXT_MATCH TYPE STRING,
CROSS_REPEATED TYPE STRING,
LOCKED TYPE STRING,
NOMATCH_MT TYPE STRING,
NOMATCH_NO_MT TYPE STRING,
STATS_W TYPE STRING,
MATCH_100 TYPE STRING,
MATCH_50TO74 TYPE STRING,
MATCH_75TO84 TYPE STRING,
MATCH_85TO94 TYPE STRING,
MATCH_95TO99 TYPE STRING,
NOMATCH TYPE STRING,
REPEATED TYPE STRING,
TOTAL TYPE STRING,
XTRANSLATED TYPE STRING,
CONTEXT_MATCH TYPE STRING,
CROSS_REPEATED TYPE STRING,
LOCKED TYPE STRING,
NOMATCH_MT TYPE STRING,
NOMATCH_NO_MT TYPE STRING,
MT_USED TYPE STRING,END OF T_EKKO_STR. DATA: WA_TMW_ASTATS_TSCON_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_TMW_ASTATS_TSCON_STR-CUSTMNR sy-vline
WA_TMW_ASTATS_TSCON_STR-OBJTYPE sy-vline
WA_TMW_ASTATS_TSCON_STR-OBJNAME sy-vline
WA_TMW_ASTATS_TSCON_STR-TEXTKEY sy-vline
WA_TMW_ASTATS_TSCON_STR-STATS_S sy-vline
WA_TMW_ASTATS_TSCON_STR-MATCH_100 sy-vline
WA_TMW_ASTATS_TSCON_STR-MATCH_50TO74 sy-vline
WA_TMW_ASTATS_TSCON_STR-MATCH_75TO84 sy-vline
WA_TMW_ASTATS_TSCON_STR-MATCH_85TO94 sy-vline
WA_TMW_ASTATS_TSCON_STR-MATCH_95TO99 sy-vline
WA_TMW_ASTATS_TSCON_STR-NOMATCH sy-vline
WA_TMW_ASTATS_TSCON_STR-REPEATED sy-vline
WA_TMW_ASTATS_TSCON_STR-TOTAL sy-vline
WA_TMW_ASTATS_TSCON_STR-XTRANSLATED sy-vline
WA_TMW_ASTATS_TSCON_STR-CONTEXT_MATCH sy-vline
WA_TMW_ASTATS_TSCON_STR-CROSS_REPEATED sy-vline
WA_TMW_ASTATS_TSCON_STR-LOCKED sy-vline
WA_TMW_ASTATS_TSCON_STR-NOMATCH_MT sy-vline
WA_TMW_ASTATS_TSCON_STR-NOMATCH_NO_MT sy-vline
WA_TMW_ASTATS_TSCON_STR-STATS_W sy-vline
WA_TMW_ASTATS_TSCON_STR-MATCH_100 sy-vline
WA_TMW_ASTATS_TSCON_STR-MATCH_50TO74 sy-vline
WA_TMW_ASTATS_TSCON_STR-MATCH_75TO84 sy-vline
WA_TMW_ASTATS_TSCON_STR-MATCH_85TO94 sy-vline
WA_TMW_ASTATS_TSCON_STR-MATCH_95TO99 sy-vline
WA_TMW_ASTATS_TSCON_STR-NOMATCH sy-vline
WA_TMW_ASTATS_TSCON_STR-REPEATED sy-vline
WA_TMW_ASTATS_TSCON_STR-TOTAL sy-vline
WA_TMW_ASTATS_TSCON_STR-XTRANSLATED sy-vline
WA_TMW_ASTATS_TSCON_STR-CONTEXT_MATCH sy-vline
WA_TMW_ASTATS_TSCON_STR-CROSS_REPEATED sy-vline
WA_TMW_ASTATS_TSCON_STR-LOCKED sy-vline
WA_TMW_ASTATS_TSCON_STR-NOMATCH_MT sy-vline
WA_TMW_ASTATS_TSCON_STR-NOMATCH_NO_MT sy-vline
WA_TMW_ASTATS_TSCON_STR-MT_USED sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.