ABAP Select data from SAP table TKETRPROT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP TKETRPROT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to TKETRPROT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the TKETRPROT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_TKETRPROT TYPE STANDARD TABLE OF TKETRPROT,
      WA_TKETRPROT TYPE TKETRPROT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <TKETRPROT> TYPE TKETRPROT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_TKETRPROT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM TKETRPROT
  INTO TABLE IT_TKETRPROT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM TKETRPROT
*  INTO TABLE @DATA(IT_TKETRPROT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_TKETRPROT INDEX 1 INTO DATA(WA_TKETRPROT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_TKETRPROT ASSIGNING <TKETRPROT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<TKETRPROT>-MANDT = 1.
<TKETRPROT>-TIMESTAMP = 1.
<TKETRPROT>-RECNR = 1.
<TKETRPROT>-APPLCLASS = 1.
<TKETRPROT>-SUBCLASS = 1.
ENDLOOP.

LOOP AT IT_TKETRPROT INTO WA_TKETRPROT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_TKETRPROT-TABNAME, sy-vline,
WA_TKETRPROT-CALLER_APPL, sy-vline,
WA_TKETRPROT-CALLER_DETAIL, sy-vline,
WA_TKETRPROT-CALLER_BATCH, sy-vline,
WA_TKETRPROT-USERNAME, sy-vline,
WA_TKETRPROT-NUMREC, sy-vline.
ENDLOOP. *Add any further fields from structure WA_TKETRPROT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_TKETRPROT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_TKETRPROT INTO WA_TKETRPROT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_TKETRPROT_STR,
MANDT TYPE STRING,
TIMESTAMP TYPE STRING,
RECNR TYPE STRING,
APPLCLASS TYPE STRING,
SUBCLASS TYPE STRING,
TABNAME TYPE STRING,
CALLER_APPL TYPE STRING,
CALLER_DETAIL TYPE STRING,
CALLER_BATCH TYPE STRING,
USERNAME TYPE STRING,
NUMREC TYPE STRING,
NUMREC_DB TYPE STRING,
TIME TYPE STRING,
NUMREC_DELTA TYPE STRING,
NUMREC_DB_DELTA TYPE STRING,
TIME_DELTA TYPE STRING,
DATASRC TYPE STRING,
TRCATNR TYPE STRING,
DVERS TYPE STRING,
PROGNAME TYPE STRING,
TCODE TYPE STRING,END OF T_EKKO_STR. DATA: WA_TKETRPROT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_TKETRPROT_STR-MANDT sy-vline
WA_TKETRPROT_STR-TIMESTAMP sy-vline
WA_TKETRPROT_STR-RECNR sy-vline
WA_TKETRPROT_STR-APPLCLASS sy-vline
WA_TKETRPROT_STR-SUBCLASS sy-vline
WA_TKETRPROT_STR-TABNAME sy-vline
WA_TKETRPROT_STR-CALLER_APPL sy-vline
WA_TKETRPROT_STR-CALLER_DETAIL sy-vline
WA_TKETRPROT_STR-CALLER_BATCH sy-vline
WA_TKETRPROT_STR-USERNAME sy-vline
WA_TKETRPROT_STR-NUMREC sy-vline
WA_TKETRPROT_STR-NUMREC_DB sy-vline
WA_TKETRPROT_STR-TIME sy-vline
WA_TKETRPROT_STR-NUMREC_DELTA sy-vline
WA_TKETRPROT_STR-NUMREC_DB_DELTA sy-vline
WA_TKETRPROT_STR-TIME_DELTA sy-vline
WA_TKETRPROT_STR-DATASRC sy-vline
WA_TKETRPROT_STR-TRCATNR sy-vline
WA_TKETRPROT_STR-DVERS sy-vline
WA_TKETRPROT_STR-PROGNAME sy-vline
WA_TKETRPROT_STR-TCODE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.