ABAP Select data from SAP table TICL163 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP TICL163 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to TICL163. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the TICL163 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_TICL163 TYPE STANDARD TABLE OF TICL163,
      WA_TICL163 TYPE TICL163,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <TICL163> TYPE TICL163.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_TICL163.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM TICL163
  INTO TABLE IT_TICL163.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM TICL163
*  INTO TABLE @DATA(IT_TICL1632).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_TICL163 INDEX 1 INTO DATA(WA_TICL1632).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_TICL163 ASSIGNING <TICL163>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<TICL163>-CLIENT = 1.
<TICL163>-BENTREE = 1.
<TICL163>-GENERAT = 1.
<TICL163>-VERSION = 1.
<TICL163>-BENTYPE = 1.
ENDLOOP.

LOOP AT IT_TICL163 INTO WA_TICL163.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_TICL163-COUNTRY, sy-vline,
WA_TICL163-REGION, sy-vline,
WA_TICL163-PRIORITY, sy-vline,
WA_TICL163-UNOPCOV, sy-vline,
WA_TICL163-CMC_RULE, sy-vline,
WA_TICL163-LIMIT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_TICL163 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_TICL163 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_TICL163 INTO WA_TICL163. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_TICL163_STR,
CLIENT TYPE STRING,
BENTREE TYPE STRING,
GENERAT TYPE STRING,
VERSION TYPE STRING,
BENTYPE TYPE STRING,
COUNTRY TYPE STRING,
REGION TYPE STRING,
PRIORITY TYPE STRING,
UNOPCOV TYPE STRING,
CMC_RULE TYPE STRING,
LIMIT TYPE STRING,
LIMAMT TYPE STRING,
DEDUCTIBLE TYPE STRING,
DEDUCTAMT TYPE STRING,
DEDUCTPERC TYPE STRING,
RBENTYPE TYPE STRING,
COVTYPE TYPE STRING,
PERCENT TYPE STRING,
LIMDEDRULE TYPE STRING,
LEGALRULE TYPE STRING,
REJREASON TYPE STRING,
REIMB_DEDUC_RULE TYPE STRING,
MINREFPERCENT TYPE STRING,
WAITINGPRD TYPE STRING,
RETROPRD TYPE STRING,
FORMULA_ID TYPE STRING,
DEDPERCRULE TYPE STRING,
GRPDEDLIM TYPE STRING,END OF T_EKKO_STR. DATA: WA_TICL163_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_TICL163_STR-CLIENT sy-vline
WA_TICL163_STR-BENTREE sy-vline
WA_TICL163_STR-GENERAT sy-vline
WA_TICL163_STR-VERSION sy-vline
WA_TICL163_STR-BENTYPE sy-vline
WA_TICL163_STR-COUNTRY sy-vline
WA_TICL163_STR-REGION sy-vline
WA_TICL163_STR-PRIORITY sy-vline
WA_TICL163_STR-UNOPCOV sy-vline
WA_TICL163_STR-CMC_RULE sy-vline
WA_TICL163_STR-LIMIT sy-vline
WA_TICL163_STR-LIMAMT sy-vline
WA_TICL163_STR-DEDUCTIBLE sy-vline
WA_TICL163_STR-DEDUCTAMT sy-vline
WA_TICL163_STR-DEDUCTPERC sy-vline
WA_TICL163_STR-RBENTYPE sy-vline
WA_TICL163_STR-COVTYPE sy-vline
WA_TICL163_STR-PERCENT sy-vline
WA_TICL163_STR-LIMDEDRULE sy-vline
WA_TICL163_STR-LEGALRULE sy-vline
WA_TICL163_STR-REJREASON sy-vline
WA_TICL163_STR-REIMB_DEDUC_RULE sy-vline
WA_TICL163_STR-MINREFPERCENT sy-vline
WA_TICL163_STR-WAITINGPRD sy-vline
WA_TICL163_STR-RETROPRD sy-vline
WA_TICL163_STR-FORMULA_ID sy-vline
WA_TICL163_STR-DEDPERCRULE sy-vline
WA_TICL163_STR-GRPDEDLIM sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.