ABAP Select data from SAP table THXS_DISP_HREL_FLOWS into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP THXS_DISP_HREL_FLOWS table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to THXS_DISP_HREL_FLOWS. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the THXS_DISP_HREL_FLOWS table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_THXS_DISP_HREL_FLOWS TYPE STANDARD TABLE OF THXS_DISP_HREL_FLOWS,
      WA_THXS_DISP_HREL_FLOWS TYPE THXS_DISP_HREL_FLOWS,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <THXS_DISP_HREL_FLOWS> TYPE THXS_DISP_HREL_FLOWS.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_THXS_DISP_HREL_FLOWS.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM THXS_DISP_HREL_FLOWS
  INTO TABLE IT_THXS_DISP_HREL_FLOWS.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM THXS_DISP_HREL_FLOWS
*  INTO TABLE @DATA(IT_THXS_DISP_HREL_FLOWS2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_THXS_DISP_HREL_FLOWS INDEX 1 INTO DATA(WA_THXS_DISP_HREL_FLOWS2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_THXS_DISP_HREL_FLOWS ASSIGNING <THXS_DISP_HREL_FLOWS>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<THXS_DISP_HREL_FLOWS>-OS_GUID = 1.
<THXS_DISP_HREL_FLOWS>-HREL_NUMBER = 1.
<THXS_DISP_HREL_FLOWS>-FISCAL_YEAR = 1.
<THXS_DISP_HREL_FLOWS>-BUSTRANSCAT = 1.
<THXS_DISP_HREL_FLOWS>-BUSTRANSCAT_T = 1.
ENDLOOP.

LOOP AT IT_THXS_DISP_HREL_FLOWS INTO WA_THXS_DISP_HREL_FLOWS.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_THXS_DISP_HREL_FLOWS-TRLDATE, sy-vline,
WA_THXS_DISP_HREL_FLOWS-TR_STATUS, sy-vline,
WA_THXS_DISP_HREL_FLOWS-BUSTRANSID, sy-vline,
WA_THXS_DISP_HREL_FLOWS-HITEM_NUMBER, sy-vline,
WA_THXS_DISP_HREL_FLOWS-HINST_NUMBER, sy-vline,
WA_THXS_DISP_HREL_FLOWS-FLOW_NUMBER, sy-vline.
ENDLOOP. *Add any further fields from structure WA_THXS_DISP_HREL_FLOWS you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_THXS_DISP_HREL_FLOWS TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_THXS_DISP_HREL_FLOWS INTO WA_THXS_DISP_HREL_FLOWS. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field HREL_NUMBER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_THXS_DISP_HREL_FLOWS-HREL_NUMBER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_THXS_DISP_HREL_FLOWS-HREL_NUMBER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field FISCAL_YEAR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_THXS_DISP_HREL_FLOWS-FISCAL_YEAR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_THXS_DISP_HREL_FLOWS-FISCAL_YEAR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field HITEM_NUMBER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_THXS_DISP_HREL_FLOWS-HITEM_NUMBER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_THXS_DISP_HREL_FLOWS-HITEM_NUMBER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field HINST_NUMBER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_THXS_DISP_HREL_FLOWS-HINST_NUMBER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_THXS_DISP_HREL_FLOWS-HINST_NUMBER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UNIT_OF_MEASURE CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_THXS_DISP_HREL_FLOWS-UNIT_OF_MEASURE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_THXS_DISP_HREL_FLOWS-UNIT_OF_MEASURE.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_THXS_DISP_HREL_FLOWS_STR,
OS_GUID TYPE STRING,
HREL_NUMBER TYPE STRING,
FISCAL_YEAR TYPE STRING,
BUSTRANSCAT TYPE STRING,
BUSTRANSCAT_T TYPE STRING,
TRLDATE TYPE STRING,
TR_STATUS TYPE STRING,
BUSTRANSID TYPE STRING,
HITEM_NUMBER TYPE STRING,
HINST_NUMBER TYPE STRING,
FLOW_NUMBER TYPE STRING,
UPDATE_TYPE TYPE STRING,
UNITS TYPE STRING,
QUAN_CAT TYPE STRING,
NOMINAL_AMT TYPE STRING,
NOMINAL_ORG_AMT TYPE STRING,
NOMINAL_CURR TYPE STRING,
SUB_SOURCETARGET TYPE STRING,
DCSID TYPE STRING,
DCSID_T TYPE STRING,
QUANTITY TYPE STRING,
UNIT_OF_MEASURE TYPE STRING,
UNIT_OF_MEASURE_T TYPE STRING,END OF T_EKKO_STR. DATA: WA_THXS_DISP_HREL_FLOWS_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_THXS_DISP_HREL_FLOWS_STR-OS_GUID sy-vline
WA_THXS_DISP_HREL_FLOWS_STR-HREL_NUMBER sy-vline
WA_THXS_DISP_HREL_FLOWS_STR-FISCAL_YEAR sy-vline
WA_THXS_DISP_HREL_FLOWS_STR-BUSTRANSCAT sy-vline
WA_THXS_DISP_HREL_FLOWS_STR-BUSTRANSCAT_T sy-vline
WA_THXS_DISP_HREL_FLOWS_STR-TRLDATE sy-vline
WA_THXS_DISP_HREL_FLOWS_STR-TR_STATUS sy-vline
WA_THXS_DISP_HREL_FLOWS_STR-BUSTRANSID sy-vline
WA_THXS_DISP_HREL_FLOWS_STR-HITEM_NUMBER sy-vline
WA_THXS_DISP_HREL_FLOWS_STR-HINST_NUMBER sy-vline
WA_THXS_DISP_HREL_FLOWS_STR-FLOW_NUMBER sy-vline
WA_THXS_DISP_HREL_FLOWS_STR-UPDATE_TYPE sy-vline
WA_THXS_DISP_HREL_FLOWS_STR-UNITS sy-vline
WA_THXS_DISP_HREL_FLOWS_STR-QUAN_CAT sy-vline
WA_THXS_DISP_HREL_FLOWS_STR-NOMINAL_AMT sy-vline
WA_THXS_DISP_HREL_FLOWS_STR-NOMINAL_ORG_AMT sy-vline
WA_THXS_DISP_HREL_FLOWS_STR-NOMINAL_CURR sy-vline
WA_THXS_DISP_HREL_FLOWS_STR-SUB_SOURCETARGET sy-vline
WA_THXS_DISP_HREL_FLOWS_STR-DCSID sy-vline
WA_THXS_DISP_HREL_FLOWS_STR-DCSID_T sy-vline
WA_THXS_DISP_HREL_FLOWS_STR-QUANTITY sy-vline
WA_THXS_DISP_HREL_FLOWS_STR-UNIT_OF_MEASURE sy-vline
WA_THXS_DISP_HREL_FLOWS_STR-UNIT_OF_MEASURE_T sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.