ABAP Select data from SAP table THXES_HITEM_N_HINST_DATA into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP THXES_HITEM_N_HINST_DATA table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to THXES_HITEM_N_HINST_DATA. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the THXES_HITEM_N_HINST_DATA table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_THXES_HITEM_N_HINST_DATA TYPE STANDARD TABLE OF THXES_HITEM_N_HINST_DATA,
      WA_THXES_HITEM_N_HINST_DATA TYPE THXES_HITEM_N_HINST_DATA,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <THXES_HITEM_N_HINST_DATA> TYPE THXES_HITEM_N_HINST_DATA.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_THXES_HITEM_N_HINST_DATA.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM THXES_HITEM_N_HINST_DATA
  INTO TABLE IT_THXES_HITEM_N_HINST_DATA.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM THXES_HITEM_N_HINST_DATA
*  INTO TABLE @DATA(IT_THXES_HITEM_N_HINST_DATA2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_THXES_HITEM_N_HINST_DATA INDEX 1 INTO DATA(WA_THXES_HITEM_N_HINST_DATA2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_THXES_HITEM_N_HINST_DATA ASSIGNING <THXES_HITEM_N_HINST_DATA>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<THXES_HITEM_N_HINST_DATA>-O_SUBPOSITION = 1.
<THXES_HITEM_N_HINST_DATA>-O_POSITION = 1.
<THXES_HITEM_N_HINST_DATA>-POSITION_DB_GUID = 1.
<THXES_HITEM_N_HINST_DATA>-EVAL_TYPE = 1.
<THXES_HITEM_N_HINST_DATA>-CURR_VAL_CAL_CAT = 1.
ENDLOOP.

LOOP AT IT_THXES_HITEM_N_HINST_DATA INTO WA_THXES_HITEM_N_HINST_DATA.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_THXES_HITEM_N_HINST_DATA-O_HINST, sy-vline,
WA_THXES_HITEM_N_HINST_DATA-HINST_OID, sy-vline,
WA_THXES_HITEM_N_HINST_DATA-HINST_NUMBER, sy-vline,
WA_THXES_HITEM_N_HINST_DATA-HINST_FISCAL_YEAR, sy-vline,
WA_THXES_HITEM_N_HINST_DATA-O_HITEM, sy-vline,
WA_THXES_HITEM_N_HINST_DATA-HITEM_OID, sy-vline.
ENDLOOP. *Add any further fields from structure WA_THXES_HITEM_N_HINST_DATA you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_THXES_HITEM_N_HINST_DATA TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_THXES_HITEM_N_HINST_DATA INTO WA_THXES_HITEM_N_HINST_DATA. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field HINST_NUMBER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_THXES_HITEM_N_HINST_DATA-HINST_NUMBER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_THXES_HITEM_N_HINST_DATA-HINST_NUMBER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field HINST_FISCAL_YEAR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_THXES_HITEM_N_HINST_DATA-HINST_FISCAL_YEAR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_THXES_HITEM_N_HINST_DATA-HINST_FISCAL_YEAR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field HITEM_NUMBER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_THXES_HITEM_N_HINST_DATA-HITEM_NUMBER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_THXES_HITEM_N_HINST_DATA-HITEM_NUMBER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field HITEM_FISCAL_YEAR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_THXES_HITEM_N_HINST_DATA-HITEM_FISCAL_YEAR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_THXES_HITEM_N_HINST_DATA-HITEM_FISCAL_YEAR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UNIT_OF_MEASURE CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_THXES_HITEM_N_HINST_DATA-UNIT_OF_MEASURE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_THXES_HITEM_N_HINST_DATA-UNIT_OF_MEASURE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UNIT_OF_MEASURE CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_THXES_HITEM_N_HINST_DATA-UNIT_OF_MEASURE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_THXES_HITEM_N_HINST_DATA-UNIT_OF_MEASURE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PARTNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_THXES_HITEM_N_HINST_DATA-PARTNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_THXES_HITEM_N_HINST_DATA-PARTNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field GRUPP CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_THXES_HITEM_N_HINST_DATA-GRUPP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_THXES_HITEM_N_HINST_DATA-GRUPP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RSIMBSTD CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_THXES_HITEM_N_HINST_DATA-RSIMBSTD IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_THXES_HITEM_N_HINST_DATA-RSIMBSTD.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RSIMLFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_THXES_HITEM_N_HINST_DATA-RSIMLFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_THXES_HITEM_N_HINST_DATA-RSIMLFNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PARTNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_THXES_HITEM_N_HINST_DATA-PARTNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_THXES_HITEM_N_HINST_DATA-PARTNR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_THXES_HITEM_N_HINST_DATA_STR,
O_SUBPOSITION TYPE STRING,
O_POSITION TYPE STRING,
POSITION_DB_GUID TYPE STRING,
EVAL_TYPE TYPE STRING,
CURR_VAL_CAL_CAT TYPE STRING,
O_HINST TYPE STRING,
HINST_OID TYPE STRING,
HINST_NUMBER TYPE STRING,
HINST_FISCAL_YEAR TYPE STRING,
O_HITEM TYPE STRING,
HITEM_OID TYPE STRING,
HITEM_NUMBER TYPE STRING,
HD_VERSION_NO TYPE STRING,
HITEM_FISCAL_YEAR TYPE STRING,
POS_QTY_AT_TEST_TIME TYPE STRING,
POS_COMP TYPE STRING,
UNITS TYPE STRING,
NOMINAL_AMT TYPE STRING,
NOMINAL_ORG_AMT TYPE STRING,
NOMINAL_CURR TYPE STRING,
POSITION_AMT TYPE STRING,
POSITION_CURR TYPE STRING,
VALUATION_AMT TYPE STRING,
VALUATION_CURR TYPE STRING,
POSAMT_IDX_CLEAN TYPE STRING,
QUANTITY TYPE STRING,
UNIT_OF_MEASURE TYPE STRING,
DES_QTY_AT_TEST_TIME TYPE STRING,
POS_COMP TYPE STRING,
UNITS TYPE STRING,
NOMINAL_AMT TYPE STRING,
NOMINAL_ORG_AMT TYPE STRING,
NOMINAL_CURR TYPE STRING,
POSITION_AMT TYPE STRING,
POSITION_CURR TYPE STRING,
VALUATION_AMT TYPE STRING,
VALUATION_CURR TYPE STRING,
POSAMT_IDX_CLEAN TYPE STRING,
QUANTITY TYPE STRING,
UNIT_OF_MEASURE TYPE STRING,
SFGDT TYPE STRING,
KOPF TYPE STRING,
OBJNR TYPE STRING,
BUKRS TYPE STRING,
RPORTB TYPE STRING,
RDEALER TYPE STRING,
PARTNR TYPE STRING,
WAEHRUNG TYPE STRING,
ARR TYPE STRING,
SLPG TYPE STRING,
GRUPP TYPE STRING,
EBENE TYPE STRING,
DISPW TYPE STRING,
ABREG TYPE STRING,
ABEST TYPE STRING,
SICHTID TYPE STRING,
BPID TYPE STRING,
RSIMBSTD TYPE STRING,
RSIMLFNR TYPE STRING,
RANTYP TYPE STRING,
SANLF TYPE STRING,
SGSART TYPE STRING,
GNUMMER TYPE STRING,
SFHAART TYPE STRING,
SFGZUSTT TYPE STRING,
RLDEPO TYPE STRING,
FGDT TYPE STRING,
FGET_T TYPE STRING,
KLPART TYPE STRING,
BUKRS TYPE STRING,
PARTNR TYPE STRING,
SLPG TYPE STRING,
RPORTB TYPE STRING,
RDEALER TYPE STRING,
WAERS TYPE STRING,
CONTROL01 TYPE STRING,
INTORG TYPE STRING,
RCOUNTRY TYPE STRING,
COUNTRY TYPE STRING,
SECTOR TYPE STRING,
RATING TYPE STRING,
CRATING TYPE STRING,
NID TYPE STRING,
CAID TYPE STRING,
FAZNR TYPE STRING,
RRFIND TYPE STRING,
CEQCLASS TYPE STRING,
LEQCLASS TYPE STRING,
LRB TYPE STRING,
SRE TYPE STRING,
SARAKT TYPE STRING,
SLRAKT TYPE STRING,
BKNZMANI TYPE STRING,
DFIKT TYPE STRING,
SKALID TYPE STRING,
DMWAE TYPE STRING,
DRBD TYPE STRING,
DBLFZ TYPE STRING,
DELFZ TYPE STRING,
DBMWAE TYPE STRING,
DFIKTVGL TYPE STRING,
OBJTYP TYPE STRING,
KREIS TYPE STRING,
EXTNR TYPE STRING,END OF T_EKKO_STR. DATA: WA_THXES_HITEM_N_HINST_DATA_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-O_SUBPOSITION sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-O_POSITION sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-POSITION_DB_GUID sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-EVAL_TYPE sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-CURR_VAL_CAL_CAT sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-O_HINST sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-HINST_OID sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-HINST_NUMBER sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-HINST_FISCAL_YEAR sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-O_HITEM sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-HITEM_OID sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-HITEM_NUMBER sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-HD_VERSION_NO sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-HITEM_FISCAL_YEAR sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-POS_QTY_AT_TEST_TIME sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-POS_COMP sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-UNITS sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-NOMINAL_AMT sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-NOMINAL_ORG_AMT sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-NOMINAL_CURR sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-POSITION_AMT sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-POSITION_CURR sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-VALUATION_AMT sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-VALUATION_CURR sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-POSAMT_IDX_CLEAN sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-QUANTITY sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-UNIT_OF_MEASURE sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-DES_QTY_AT_TEST_TIME sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-POS_COMP sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-UNITS sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-NOMINAL_AMT sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-NOMINAL_ORG_AMT sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-NOMINAL_CURR sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-POSITION_AMT sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-POSITION_CURR sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-VALUATION_AMT sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-VALUATION_CURR sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-POSAMT_IDX_CLEAN sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-QUANTITY sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-UNIT_OF_MEASURE sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-SFGDT sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-KOPF sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-OBJNR sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-BUKRS sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-RPORTB sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-RDEALER sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-PARTNR sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-WAEHRUNG sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-ARR sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-SLPG sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-GRUPP sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-EBENE sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-DISPW sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-ABREG sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-ABEST sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-SICHTID sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-BPID sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-RSIMBSTD sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-RSIMLFNR sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-RANTYP sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-SANLF sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-SGSART sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-GNUMMER sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-SFHAART sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-SFGZUSTT sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-RLDEPO sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-FGDT sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-FGET_T sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-KLPART sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-BUKRS sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-PARTNR sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-SLPG sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-RPORTB sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-RDEALER sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-WAERS sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-CONTROL01 sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-INTORG sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-RCOUNTRY sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-COUNTRY sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-SECTOR sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-RATING sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-CRATING sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-NID sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-CAID sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-FAZNR sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-RRFIND sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-CEQCLASS sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-LEQCLASS sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-LRB sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-SRE sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-SARAKT sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-SLRAKT sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-BKNZMANI sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-DFIKT sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-SKALID sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-DMWAE sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-DRBD sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-DBLFZ sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-DELFZ sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-DBMWAE sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-DFIKTVGL sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-OBJTYP sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-KREIS sy-vline
WA_THXES_HITEM_N_HINST_DATA_STR-EXTNR sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.