ABAP Select data from SAP table TFK8265R into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP TFK8265R table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to TFK8265R. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the TFK8265R table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_TFK8265R TYPE STANDARD TABLE OF TFK8265R,
      WA_TFK8265R TYPE TFK8265R,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <TFK8265R> TYPE TFK8265R.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_TFK8265R.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM TFK8265R
  INTO TABLE IT_TFK8265R.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM TFK8265R
*  INTO TABLE @DATA(IT_TFK8265R2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_TFK8265R INDEX 1 INTO DATA(WA_TFK8265R2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_TFK8265R ASSIGNING <TFK8265R>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<TFK8265R>-MANDT = 1.
<TFK8265R>-CO_AMOUNT_CALC_KEY = 1.
<TFK8265R>-WAERS = 1.
<TFK8265R>-DATE_FROM = 1.
<TFK8265R>-BASAMT_SIGN = 1.
ENDLOOP.

LOOP AT IT_TFK8265R INTO WA_TFK8265R.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_TFK8265R-BASAMT_FROM, sy-vline,
WA_TFK8265R-AMT_MIN, sy-vline,
WA_TFK8265R-AMT_MAX, sy-vline,
WA_TFK8265R-OFFSETRU, sy-vline,
WA_TFK8265R-BASDEDUC, sy-vline,
WA_TFK8265R-BASRNDUN, sy-vline.
ENDLOOP. *Add any further fields from structure WA_TFK8265R you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_TFK8265R TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_TFK8265R INTO WA_TFK8265R. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_TFK8265R_STR,
MANDT TYPE STRING,
CO_AMOUNT_CALC_KEY TYPE STRING,
WAERS TYPE STRING,
DATE_FROM TYPE STRING,
BASAMT_SIGN TYPE STRING,
BASAMT_FROM TYPE STRING,
AMT_MIN TYPE STRING,
AMT_MAX TYPE STRING,
OFFSETRU TYPE STRING,
BASDEDUC TYPE STRING,
BASRNDUN TYPE STRING,
BASRNDRU TYPE STRING,
PERC TYPE STRING,
RNDUN TYPE STRING,
RNDRU TYPE STRING,
PERRU TYPE STRING,END OF T_EKKO_STR. DATA: WA_TFK8265R_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_TFK8265R_STR-MANDT sy-vline
WA_TFK8265R_STR-CO_AMOUNT_CALC_KEY sy-vline
WA_TFK8265R_STR-WAERS sy-vline
WA_TFK8265R_STR-DATE_FROM sy-vline
WA_TFK8265R_STR-BASAMT_SIGN sy-vline
WA_TFK8265R_STR-BASAMT_FROM sy-vline
WA_TFK8265R_STR-AMT_MIN sy-vline
WA_TFK8265R_STR-AMT_MAX sy-vline
WA_TFK8265R_STR-OFFSETRU sy-vline
WA_TFK8265R_STR-BASDEDUC sy-vline
WA_TFK8265R_STR-BASRNDUN sy-vline
WA_TFK8265R_STR-BASRNDRU sy-vline
WA_TFK8265R_STR-PERC sy-vline
WA_TFK8265R_STR-RNDUN sy-vline
WA_TFK8265R_STR-RNDRU sy-vline
WA_TFK8265R_STR-PERRU sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.