ABAP Select data from SAP table TFK8170 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP TFK8170 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to TFK8170. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the TFK8170 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_TFK8170 TYPE STANDARD TABLE OF TFK8170,
      WA_TFK8170 TYPE TFK8170,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <TFK8170> TYPE TFK8170.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_TFK8170.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM TFK8170
  INTO TABLE IT_TFK8170.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM TFK8170
*  INTO TABLE @DATA(IT_TFK81702).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_TFK8170 INDEX 1 INTO DATA(WA_TFK81702).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_TFK8170 ASSIGNING <TFK8170>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<TFK8170>-MANDT = 1.
<TFK8170>-RATING_GROUP = 1.
<TFK8170>-KEYPP_CRIT1 = 1.
<TFK8170>-KEYPP_CRIT2 = 1.
<TFK8170>-KEYPP_CRIT3 = 1.
ENDLOOP.

LOOP AT IT_TFK8170 INTO WA_TFK8170.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_TFK8170-KEYPP_NUM_BP, sy-vline,
WA_TFK8170-CITCNT_SELPACK, sy-vline,
WA_TFK8170-CITCNT_RATEPACK, sy-vline,
WA_TFK8170-CITCNT_AGGRITEM, sy-vline,
WA_TFK8170-CITCNT_AGGRUPD, sy-vline,
WA_TFK8170-CITCNT_AGGRMIN, sy-vline.
ENDLOOP. *Add any further fields from structure WA_TFK8170 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_TFK8170 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_TFK8170 INTO WA_TFK8170. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_TFK8170_STR,
MANDT TYPE STRING,
RATING_GROUP TYPE STRING,
KEYPP_CRIT1 TYPE STRING,
KEYPP_CRIT2 TYPE STRING,
KEYPP_CRIT3 TYPE STRING,
KEYPP_NUM_BP TYPE STRING,
CITCNT_SELPACK TYPE STRING,
CITCNT_RATEPACK TYPE STRING,
CITCNT_AGGRITEM TYPE STRING,
CITCNT_AGGRUPD TYPE STRING,
CITCNT_AGGRMIN TYPE STRING,
GRVAR TYPE STRING,
XAGGREGATE_BITS TYPE STRING,
BILL_PROCESS TYPE STRING,END OF T_EKKO_STR. DATA: WA_TFK8170_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_TFK8170_STR-MANDT sy-vline
WA_TFK8170_STR-RATING_GROUP sy-vline
WA_TFK8170_STR-KEYPP_CRIT1 sy-vline
WA_TFK8170_STR-KEYPP_CRIT2 sy-vline
WA_TFK8170_STR-KEYPP_CRIT3 sy-vline
WA_TFK8170_STR-KEYPP_NUM_BP sy-vline
WA_TFK8170_STR-CITCNT_SELPACK sy-vline
WA_TFK8170_STR-CITCNT_RATEPACK sy-vline
WA_TFK8170_STR-CITCNT_AGGRITEM sy-vline
WA_TFK8170_STR-CITCNT_AGGRUPD sy-vline
WA_TFK8170_STR-CITCNT_AGGRMIN sy-vline
WA_TFK8170_STR-GRVAR sy-vline
WA_TFK8170_STR-XAGGREGATE_BITS sy-vline
WA_TFK8170_STR-BILL_PROCESS sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.