ABAP Select data from SAP table TF696 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP TF696 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to TF696. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the TF696 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_TF696 TYPE STANDARD TABLE OF TF696,
      WA_TF696 TYPE TF696,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <TF696> TYPE TF696.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_TF696.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM TF696
  INTO TABLE IT_TF696.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM TF696
*  INTO TABLE @DATA(IT_TF6962).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_TF696 INDEX 1 INTO DATA(WA_TF6962).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_TF696 ASSIGNING <TF696>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<TF696>-MANDT = 1.
<TF696>-FIXVS = 1.
<TF696>-ITCLG = 1.
<TF696>-DTEQI = 1.
<TF696>-ROLE_ID_EHA_INV = 1.
ENDLOOP.

LOOP AT IT_TF696 INTO WA_TF696.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_TF696-ROLE_VAL_ID_EHA_INV, sy-vline,
WA_TF696-ITEM, sy-vline,
WA_TF696-SITYP, sy-vline,
WA_TF696-SITEMD, sy-vline,
WA_TF696-SITEMC, sy-vline,
WA_TF696-ROLE_ID_EHA_OFFS_DEB, sy-vline.
ENDLOOP. *Add any further fields from structure WA_TF696 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_TF696 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_TF696 INTO WA_TF696. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field FIXVS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_TF696-FIXVS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_TF696-FIXVS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit BFIMC, internal->external for field ITEM CALL FUNCTION 'CONVERSION_EXIT_BFIMC_OUTPUT' EXPORTING input = WA_TF696-ITEM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_TF696-ITEM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit BFIMC, internal->external for field CITEMD CALL FUNCTION 'CONVERSION_EXIT_BFIMC_OUTPUT' EXPORTING input = WA_TF696-CITEMD IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_TF696-CITEMD.
WRITE:/ 'New Value:', ld_input.

*Conversion exit BFIMC, internal->external for field CITEMC CALL FUNCTION 'CONVERSION_EXIT_BFIMC_OUTPUT' EXPORTING input = WA_TF696-CITEMC IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_TF696-CITEMC.
WRITE:/ 'New Value:', ld_input.

*Conversion exit BFIMC, internal->external for field STITEM CALL FUNCTION 'CONVERSION_EXIT_BFIMC_OUTPUT' EXPORTING input = WA_TF696-STITEM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_TF696-STITEM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit BFIMC, internal->external for field DITEMD CALL FUNCTION 'CONVERSION_EXIT_BFIMC_OUTPUT' EXPORTING input = WA_TF696-DITEMD IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_TF696-DITEMD.
WRITE:/ 'New Value:', ld_input.

*Conversion exit BFIMC, internal->external for field DITEMC CALL FUNCTION 'CONVERSION_EXIT_BFIMC_OUTPUT' EXPORTING input = WA_TF696-DITEMC IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_TF696-DITEMC.
WRITE:/ 'New Value:', ld_input.

*Conversion exit BFIMC, internal->external for field NITEM CALL FUNCTION 'CONVERSION_EXIT_BFIMC_OUTPUT' EXPORTING input = WA_TF696-NITEM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_TF696-NITEM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit BFIMC, internal->external for field NCITEM CALL FUNCTION 'CONVERSION_EXIT_BFIMC_OUTPUT' EXPORTING input = WA_TF696-NCITEM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_TF696-NCITEM.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_TF696_STR,
MANDT TYPE STRING,
FIXVS TYPE STRING,
ITCLG TYPE STRING,
DTEQI TYPE STRING,
ROLE_ID_EHA_INV TYPE STRING,
ROLE_VAL_ID_EHA_INV TYPE STRING,
ITEM TYPE STRING,
SITYP TYPE STRING,
SITEMD TYPE STRING,
SITEMC TYPE STRING,
ROLE_ID_EHA_OFFS_DEB TYPE STRING,
ROLE_VAL_ID_EHA_OFFS_DEB TYPE STRING,
CITEMD TYPE STRING,
CSITYPD TYPE STRING,
CSITEMD TYPE STRING,
ROLE_ID_EHA_OFFS_CRED TYPE STRING,
ROLE_VAL_ID_EHA_OFFS_CRED TYPE STRING,
CITEMC TYPE STRING,
CSITYPC TYPE STRING,
CSITEMC TYPE STRING,
STITEM TYPE STRING,
ROLE_ID_EHA_DIV_DEB TYPE STRING,
ROLE_VAL_ID_EHA_DIV_DEB TYPE STRING,
DITEMD TYPE STRING,
DSITYPD TYPE STRING,
DSITEMD TYPE STRING,
ROLE_ID_EHA_DIV_CRED TYPE STRING,
ROLE_VAL_ID_EHA_DIV_CRED TYPE STRING,
DITEMC TYPE STRING,
DSITYPC TYPE STRING,
DSITEMC TYPE STRING,
NITEM TYPE STRING,
NSITYP TYPE STRING,
NSITEM TYPE STRING,
NCITEM TYPE STRING,
NCSITYP TYPE STRING,
NCSITEM TYPE STRING,END OF T_EKKO_STR. DATA: WA_TF696_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_TF696_STR-MANDT sy-vline
WA_TF696_STR-FIXVS sy-vline
WA_TF696_STR-ITCLG sy-vline
WA_TF696_STR-DTEQI sy-vline
WA_TF696_STR-ROLE_ID_EHA_INV sy-vline
WA_TF696_STR-ROLE_VAL_ID_EHA_INV sy-vline
WA_TF696_STR-ITEM sy-vline
WA_TF696_STR-SITYP sy-vline
WA_TF696_STR-SITEMD sy-vline
WA_TF696_STR-SITEMC sy-vline
WA_TF696_STR-ROLE_ID_EHA_OFFS_DEB sy-vline
WA_TF696_STR-ROLE_VAL_ID_EHA_OFFS_DEB sy-vline
WA_TF696_STR-CITEMD sy-vline
WA_TF696_STR-CSITYPD sy-vline
WA_TF696_STR-CSITEMD sy-vline
WA_TF696_STR-ROLE_ID_EHA_OFFS_CRED sy-vline
WA_TF696_STR-ROLE_VAL_ID_EHA_OFFS_CRED sy-vline
WA_TF696_STR-CITEMC sy-vline
WA_TF696_STR-CSITYPC sy-vline
WA_TF696_STR-CSITEMC sy-vline
WA_TF696_STR-STITEM sy-vline
WA_TF696_STR-ROLE_ID_EHA_DIV_DEB sy-vline
WA_TF696_STR-ROLE_VAL_ID_EHA_DIV_DEB sy-vline
WA_TF696_STR-DITEMD sy-vline
WA_TF696_STR-DSITYPD sy-vline
WA_TF696_STR-DSITEMD sy-vline
WA_TF696_STR-ROLE_ID_EHA_DIV_CRED sy-vline
WA_TF696_STR-ROLE_VAL_ID_EHA_DIV_CRED sy-vline
WA_TF696_STR-DITEMC sy-vline
WA_TF696_STR-DSITYPC sy-vline
WA_TF696_STR-DSITEMC sy-vline
WA_TF696_STR-NITEM sy-vline
WA_TF696_STR-NSITYP sy-vline
WA_TF696_STR-NSITEM sy-vline
WA_TF696_STR-NCITEM sy-vline
WA_TF696_STR-NCSITYP sy-vline
WA_TF696_STR-NCSITEM sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.